文献速递关节外科

金属对聚乙烯全髋关节置换术后锥度腐蚀不良局部组织反应的MARS MRI特征与金属对金属全髋关节置换术不同

MARS MRI Characteristics of Adverse Local Tissue Reactions in Taper Corrosion of Metal-On-Polyethylene THA Differ From Metal-On-Metal THA.
PubMed 文献 · J Arthroplasty · 2020-06-12

研究纳入197例不良局部组织反应(ALTR)患者,其中金属对金属(MoM)全髋关节置换术(THA)86例、头颈锥度腐蚀的金属对聚乙烯(MoP)患者37例、颈干双锥度腐蚀的MoP患者74例,比较其MARS MRI特征。结果显示MoM与MoP组ALTR的MARS MRI特征显著不同(P=0.017),MoP组II型厚壁囊性肿块比例最高,MoM组I型薄壁囊性肿块比例最高且多部位ALTR比例达96.8%。

要点

  • MoM与MoP组ALTR的MARS MRI特征显著不同(P=0.017)。
  • II型厚壁囊性肿块在头颈锥度腐蚀MoP组占56.7%、双锥度腐蚀MoP组占46.5%,高于MoM组的28.7%。
  • MoM组多部位ALTR占96.8%,显著高于两个MoP组(P=0.001)。

核心结论

  • MARS MRI显示的ALTR特征因 bearing type 而异,锥度腐蚀MoP THA中混合型和实性ALTR比例显著高于MoM THA。
  • 该信息为评估有症状的MoP和MoM THA患者的ALTR提供临床有用的信息。

研究设计与样本

  • 共评估197例ALTR患者:MoM THA 86例;头颈锥度腐蚀MoP患者37例;颈干双锥度腐蚀MoP患者74例。
  • 评估MARS MRI扫描以识别ALTR的位置、大小、类型(I-III型)及相关ALTR滑膜炎(囊性、实性、混合性)。

主要发现

  • MoM与MoP组ALTR的MARS MRI特征显著不同(P=0.017)。
  • MoP组II型厚壁囊性肿块比例最高:头颈锥度腐蚀MoP组56.7%、双锥度腐蚀MoP组46.5%,而MoM组为28.7%。
  • MoM组I型薄壁囊性肿块比例最高。
  • MoM假体(96.8%)在多个部位出现ALTR的可能性显著高于两个MoP组(P=0.001)。

关键数值与推荐

  • ALTR分型采用I-III型。
  • 相关ALTR滑膜炎分为囊性、实性和混合性。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has been recommended as a cross-sectional imaging modality in clinical evaluation of adverse local tissue reactions (ALTRs) in metal-on-metal (MoM) patients and metal-on-polyethylene (MoP) patients with taper corrosion. The aim of the study was to compare MARS MRI characteristics of ALTR in MoM total hip arthroplasty (THA) with ALTR in MoP THA with modular taper corrosion. METHODS: A total of 197 patients with ALTR were evaluated: 86 patients with MoM THA; 37 MoP patients with head-neck taper corrosion; and 74 MoP patients with neck-stem dual taper corrosion. MARS MRI scans were evaluated to identify location, size, type of ALTR (I-III), and associated ALTR synovitis (cystic, solid, and mixed). RESULTS: MARS MRI characteristics of ALTR were significantly different between the MoM and MoP groups (P = .017). The MoP group demonstrated the highest proportion of thick-walled cystic masses type II (56.7% in head-neck taper corrosion MoP and 46.5% in dual taper corrosion MoP vs 28.7% in MoM), whereas the MoM group had the highest proportion of thin-walled cystic masses type I. MoM implants (96.8%) were significantly more likely to have ALTR in multiple locations compared with both MoP groups (P = .001). CONCLUSION: This study demonstrates that MARS MRI characteristics of ALTR differ by bearing type with a significantly higher percentage of mixed type and solid type ALTR in the taper corrosion MoP THA compared with MoM THA. This information provides clinically useful information in evaluation of symptomatic MoP and MoM THA patients for ALTRs.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Mahajan J, Bonner B, Oganesyan R, et al. MARS MRI Characteristics of Adverse Local Tissue Reactions in Taper Corrosion of Metal-On-Polyethylene THA Differ From Metal-On-Metal THA. J Arthroplasty. 2020. PMID: 32622715. doi:10.1016/j.arth.2020.06.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。