采用聚乙烯衬垫厚度增量1毫米的当前假体可减少后稳定型全膝关节置换术中胫骨后倾角的调整
回顾性比较154例采用Persona(当前假体,聚乙烯衬垫厚度增量1毫米)与NexGen(前代假体,增量2毫米)的后稳定型全膝关节置换术,术后胫骨后倾角当前组显著低于前代组(4.6° vs 6.2°,P < .001),当前组无过度胫骨后倾角病例而前代组有9例(5.8%)(P = .030),当前假体可降低胫骨后倾角及过度胫骨后倾角的发生。
要点
- 当前假体组术后胫骨后倾角显著低于前代假体组(4.6° vs 6.2°,P < .001)。
- 当前假体组无过度胫骨后倾角(>10°)病例,前代组有9例(5.8%)(P = .030)。
- 前代假体组术中行胫骨后倾角增大操作的比例更高(21.4% vs 12.3%,P = .047)。
核心结论
- 采用聚乙烯衬垫厚度增量1毫米的当前假体可降低后稳定型全膝关节置换术的胫骨后倾角及过度胫骨后倾角的发生。
- 使用当前假体时,全膝关节置换术的胫骨后倾角目标角度可比前代假体更低。
研究设计与样本
- 回顾性比较154例后稳定型全膝关节置换术,当前组使用Persona假体(聚乙烯衬垫厚度增量1毫米),前代组使用NexGen假体(增量2毫米),每组各154例,最低随访2年。
- 术前人口学特征(年龄、性别、体重指数)两组相似,影响屈曲间隙的因素(术前活动度、机械轴、胫骨后倾角、术前及术后股骨后髁偏距及股骨后髁偏距比)经过匹配。
- 胫骨后倾角通过影像学评估,并调查过度胫骨后倾角(胫骨后倾角>10°)的发生率及术中行胫骨后倾角增大操作的频率。
主要发现
- 术前及术后活动度、机械轴、股骨后髁偏距及股骨后髁偏距比两组间无显著差异。
- 术前胫骨后倾角两组无显著差异,但术后胫骨后倾角当前组显著低于前代组(4.6° vs 6.2°,P < .001)。
- 当前组无过度胫骨后倾角病例,前代组有9例(5.8%)(P = .030)。
- 术中行胫骨后倾角增大操作前代组更频繁(21.4% vs 12.3%,P = .047)。
关键数值与推荐
- 过度胫骨后倾角定义为胫骨后倾角>10°。
- 当前组过度胫骨后倾角发生0例,前代组9例(5.8%)(P = .030)。
- 术后胫骨后倾角当前组4.6° vs 前代组6.2°(P < .001)。
- 术中行胫骨后倾角增大操作当前组12.3% vs 前代组21.4%(P = .047)。
临床怎么用
- 作者认为,使用当前假体时全膝关节置换术的胫骨后倾角目标角度可比前代假体更低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To compare posterior tibial slope (PTS) and incidence of excessive PTS between cruciate-retaining (CR) total knee arthroplasties (TKAs) with the current prosthesis, providing a 1-mm increment of polyethylene insert thickness, and its predecessor, providing a 2-mm increment. METHODS: Each of 154 CR TKAs with Persona (current group) and NexGen (predecessor group) prostheses with a minimum follow-up period of 2 years were retrospectively reviewed. Preoperative demographics, including age, sex, and body mass index, were similar. Factors affecting the flexion gap were matched in terms of preoperative range of motion, mechanical axis, PTS, preoperative and postoperative posterior femoral offset (PFO), and PFO ratio. The PTS was evaluated radiographically. The incidence of excessive PTS (PTS > 10°) and the frequency of intraoperative PTS-increasing procedures were investigated. RESULTS: There were no significant differences in preoperative and postoperative range of motion, mechanical axis, PFO, and PFO ratios between the 2 groups. The preoperative PTS was not significantly different, but the postoperative PTS was significantly lower in the current group (4.6° vs 6.2°, P < .001). There was no case of excessive PTS in the current group, but there were 9 cases (5.8%) in the predecessor group (P = .030). The intraoperative PTS-increasing procedure was performed more frequently in the predecessor group (12.3% vs 21.4%, P = .047). CONCLUSION: The current prosthesis providing a 1-mm increment of polyethylene insert thickness could decrease the PTS and the occurrence of excessive PTS in CR TKA. The target angle for PTS can be decreased in TKA using the current prosthesis in comparison with its predecessor. LEVEL OF EVIDENCE: III.
引用
- Song SJ, Lee HW, Park CH, et al. A Current Prosthesis With a 1-mm Thickness Increment for Polyethylene Insert Could Result in Fewer Adjustments of Posterior Tibial Slope in Cruciate-Retaining Total Knee Arthroplasty. J Arthroplasty. 2020. PMID: 32665154. doi:10.1016/j.arth.2020.06.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。