文献速递关节外科

血清与滑液标志物在金属对聚乙烯全髋关节置换头颈锥度腐蚀感染诊断中的敏感性与特异性

Sensitivity and Specificity of Serum and Synovial Fluid Markers in Diagnosis of Infection in Head-Neck Taper Corrosion of Metal-On-Polyethylene Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-06-23

该研究纳入89例因头颈锥度腐蚀失败的金属对聚乙烯全髋关节置换患者,分为感染组11例和非感染组78例,评估血沉、C反应蛋白及滑液标志物诊断假体周围关节感染的效用。结果显示滑液白细胞计数和中性粒细胞百分比诊断价值较高,血沉和C反应蛋白有助于排除感染,血清金属离子水平两组间无显著差异。

要点

  • 滑液白细胞计数最佳截断值2144,敏感性93%、特异性84%。
  • 滑液中性粒细胞百分比最佳截断值82%,敏感性93%、特异性82%。
  • 血沉和C反应蛋白有助于排除假体周围关节感染。

核心结论

  • 血沉和C反应蛋白有助于排除假体周围关节感染,而髋关节穿刺滑液白细胞计数和中性粒细胞百分比是诊断金属对聚乙烯全髋关节置换头颈锥度腐蚀相关不良局部组织反应患者感染的有用标志物。

研究设计与样本

  • 研究纳入89例连续金属对聚乙烯全髋关节置换伴头颈锥度腐蚀患者,分为感染组11例和非感染组78例,所有患者均使用高交联聚乙烯与钴铬股骨头并接受术前滑液穿刺,同时分析血清钴和铬水平。

主要发现

  • 滑液白细胞计数最佳截断值为2144,敏感性93%、特异性84%。
  • 滑液中性粒细胞百分比最佳截断值为82%,敏感性93%、特异性82%。
  • 血沉最佳截断值为57 mm/h,敏感性57%、特异性94%;C反应蛋白最佳截断值为35 mg/L,敏感性93%、特异性76%。
  • 感染组与非感染组之间金属离子水平无显著差异。

关键数值与推荐

  • 滑液白细胞计数最佳截断值2144,敏感性93%、特异性84%。
  • 滑液中性粒细胞百分比最佳截断值82%,敏感性93%、特异性82%。
  • 血沉最佳截断值57 mm/h,敏感性57%、特异性94%。
  • C反应蛋白最佳截断值35 mg/L,敏感性93%、特异性76%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The accurate diagnosis of periprosthetic joint infection (PJI) in the setting of adverse local tissue reactions in patients with metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to head-neck taper junction corrosion is challenging as it frequently has the appearance of purulence. The aim of this study is to evaluate the utility of erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and synovial fluid markers in diagnosing PJI in failed MoP THA due to head-neck taper corrosion. METHODS: A total of 89 consecutive patients with MoP THA with head-neck taper corrosion in 2 groups was evaluated: (1) infection group (n = 11) and (2) noninfection group (n = 78). All patients had highly crossed polyethylene with cobalt chromium femoral heads and had preoperative synovial fluid aspiration. In addition, serum cobalt and chromium levels were analyzed. RESULTS: The optimal cutoff value for synovial white blood cell was 2144 with 93% sensitivity and 84% specificity. Neutrophil count optimal cutoff value was 82% with 93% sensitivity and 82% specificity. Receiver operating characteristic analysis of ESR and CRP determined optimal cutoff at 57 mm/h and 35 mg/L with 57% sensitivity and 94% specificity and 93% sensitivity and 76% specificity, respectively. There were no significant differences in metal ion levels between the infected and noninfected groups. CONCLUSION: The results of this study suggest that ESR and CRP are useful in excluding PJI, whereas both synovial white blood cell count and neutrophil percentage in hip aspirate are useful markers for diagnosing infection in MoP THA patients with head-neck taper corrosion associated adverse local tissue reaction.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kwon YM, Mahajan J, Tirumala V, et al. Sensitivity and Specificity of Serum and Synovial Fluid Markers in Diagnosis of Infection in Head-Neck Taper Corrosion of Metal-On-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2020. PMID: 32665158. doi:10.1016/j.arth.2020.06.058

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。