初次全髋关节置换术后短外旋肌与后关节囊成功重建后的术后失败频率:超声评估
这项前瞻性观察研究纳入2019年1月至12月经后外侧入路行初次全髋关节置换术中短外旋肌与后关节囊成功重建的68例患者,术后6至8周超声评估重建状态。重建失败率为16.2%(n=11,95%CI 9.3-26.7)。股骨偏心距增加在失败组更常见(36.4% vs 17.5%),下肢长度差异呈相似趋势(36.4% vs 22.8%),但差异均无统计学意义(P>.05)。
要点
- 术后6至8周超声评估短外旋肌与后关节囊重建失败率为16.2%(95%CI 9.3-26.7)。
- 股骨偏心距增加在失败组36.4% vs 非失败组17.5%,差异无统计学意义(P>.05)。
- 下肢长度差异在失败组36.4% vs 非失败组22.8%,差异无统计学意义(P>.05)。
核心结论
- 术后第6至8周,术中采用可吸收缝线成功修复的短外旋肌与后关节囊重建中约10例有2例失败。
- 该失败率估计与既往报道相当甚至更低。
研究设计与样本
- 前瞻性观察研究,纳入2019年1月至12月经后外侧入路行初次全髋关节置换术且术中短外旋肌与后关节囊成功重建的患者。
- 共纳入68例患者,平均年龄58.7±13.8岁,女性占44.1%(30例)。
- 术后6至8周采用超声评估重建状态,以内外旋时重建结构未完全显示定义为重建失败。
- 证据等级:II级,前瞻性观察研究。
主要发现
- 短外旋肌与后关节囊重建失败率为16.2%(n=11,95%CI 9.3-26.7)。
- 术后股骨偏心距增加在失败组更常见(36.4% vs 17.5%),差异无统计学意义(P>.05)。
- 下肢长度差异在失败组呈相似趋势(36.4% vs 22.8%),差异无统计学意义(P>.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The reinsertion of the short external rotators and posterior capsule to the greater trochanter in the posterolateral approach has been considered an effective strategy to reduce the risk of dislocation. However, during clinical practice, no verification and monitoring of the status of such reinsertions is carried out. The objective of this study is to estimate the frequency of postoperative failure with successful reinsertion of the short external rotator and posterior capsule of the hip through ultrasound after primary total hip arthroplasty (THA) using the posterolateral approach. METHODS: A prospective observational study was conducted involving patients with primary total hip arthroplasty via posterolateral approach in which reinsertion of hip's short external rotators and posterior capsule were successful reinserted during surgery from January to December 2019. The status of the reinsertion was assessed with an ultrasound between the 6 and 8 weeks after surgery. Reinsertion failure was considered when the reinserted structures were not fully visualized in the ultrasound during internal and external rotation. RESULTS: Sixty-eight patients were included in this study (mean age: 58.7 ± 13.8 years; 44.1% (30) women). The incidence of failure of the reinsertion of short external rotators and posterior capsule was 16.2% (n = 11) (95% confidence interval 9.3-26.7). A postoperative increased femoral offset was found more frequently in cases with failure (36.4% vs 17.5%); a similar trend was observed in the leg length discrepancy (36.4% vs 22.8%). However, these differences were not statistically significant (P > .05). CONCLUSION: Between the 6th and 8th postoperative week, approximately 2 of the 10 short external rotator and posterior capsule reinsertions fail in cases with successful intraoperative repair using absorbable suture. This estimate is comparable and even lower than previous reports. EVIDENCE LEVEL: II, Prospective Observational Study.
引用
- Stangl-Correa P, Stangl-Herrera W, Correa-Valderrama A, et al. Postoperative Failure Frequency of Short External Rotator and Posterior Capsule With Successful Reinsertion After Primary Total Hip Arthroplasty: An Ultrasound Assessment. J Arthroplasty. 2020. PMID: 32684400. doi:10.1016/j.arth.2020.06.065
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。