文献速递关节外科

运动学对线与患者特异性器械全膝关节置换术与其他全膝关节置换术的翻修风险相似:澳大利亚与新西兰关节置换登记系统的合并结果

Similar Risk of Revision After Kinematically Aligned, Patient-Specific Instrumented Total Knee Arthroplasty, and All Other Total Knee Arthroplasty: Combined Results From the Australian and New Zealand Joint Replacement Registries.
PubMed 文献 · J Arthroplasty · 2020-06-01

该观察性研究基于澳大利亚和新西兰两个国家关节登记系统,纳入2011年1月至2013年12月31日期间所有使用Triathlon后交叉韧带保留型全膝关节置换术(TKA)的患者,比较采用无限制运动学对线(KA)结合患者特异性器械(PSI)与计算机辅助手术及常规器械植入的同一设计TKA的生存率。主要结局为首次翻修时间,采用Kaplan-Meier生存估计和校正年龄、性别的Cox比例风险比进行比较。结果显示,KA-PSI组7年累积翻修率为3.1%,其他Triathlon TKA组为3.0%(P=0.89),结论为KA-PSI Triathlon TKA的翻修率与其他Triathlon TKA相似。

要点

  • KA-PSI组7年累积翻修率为3.1%,其他Triathlon TKA组为3.0%(P=0.89),两组翻修率相似。
  • KA-PSI组患者更年轻(66.8±8.2岁 vs 68.3±9.2岁,P=0.001),性别分布相同。
  • KA-PSI组最常见的翻修原因为轨迹不良、髌骨侵蚀和关节纤维化。

核心结论

  • 使用PSI的运动学对线Triathlon TKA的翻修率与所有其他Triathlon TKA相似。

研究设计与样本

  • 观察性研究,基于澳大利亚和新西兰两个国家关节登记系统的数据,纳入2011年1月至2013年12月31日期间所有接受Triathlon后交叉韧带保留型TKA(Stryker, Mahwah, NJ)的患者。
  • 共记录20,512例TKA手术,其中416例使用KA-PSI;将无限制KA结合PSI的膝关节与计算机辅助手术及常规器械Triathlon后交叉韧带保留型TKA进行比较。
  • 主要结局指标为首次翻修时间,采用Kaplan-Meier生存估计;使用校正年龄和性别的Cox比例风险比比较两组。

主要发现

  • KA-PSI组患者更年轻(66.8±8.2岁 vs 68.3±9.2岁,P=0.001),性别分布相同。
  • KA-PSI Triathlon队列7年累积翻修率为3.1%,其他Triathlon TKA队列为3.0%(P=0.89)。
  • KA-PSI组最常见的翻修原因为轨迹不良、髌骨侵蚀和关节纤维化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Kinematic alignment (KA) in total knee arthroplasty (TKA) replicates individual knee joint line orientation and physiological soft tissue balance. There are limited data on the effect of KA on survivorship compared with other methods of implanting a TKA. The aim of this study was to compare the survivorship of the same design of TKA implanted with either patient-specific instrument (PSI) KA or with computer-assisted surgery and conventionally instrumented. METHODS: We performed an observational study of data from 2 national joint registries on all patients who underwent a TKA with a Triathlon cruciate-retaining TKA (Stryker, Mahwah, NJ) from January 2011 to December 31, 2013. The outcomes of knees performed with unrestricted KA using patient-specific instrument were compared with computer-assisted surgery and conventionally instrumented Triathlon cruciate-retaining TKA. The principal outcome measure was time to first revision using Kaplan-Meier estimates of survivorship. Cox proportional hazard ratios, adjusted for age and gender, were used to compare the 2 groups. RESULTS: There were 20,512 TKA procedures recorded, of which 416 were performed using KA-PSI. The KA-PSI group was younger (66.8 ± 8.2 vs 68.3 ± 9.2, P = .001), with an identical gender distribution. The cumulative revision rate at 7 years was 3.1% for the KA-PSI Triathlon cohort and 3.0% for the other Triathlon TKA cohort (P = .89). The most common reasons for revision in the KA-PSI group were maltracking, patella erosion, and arthrofibrosis. CONCLUSION: Kinematically aligned Triathlon TKA using PSI has similar revision rate as all other Triathlon TKA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Klasan A, de Steiger R, Holland S, et al. Similar Risk of Revision After Kinematically Aligned, Patient-Specific Instrumented Total Knee Arthroplasty, and All Other Total Knee Arthroplasty: Combined Results From the Australian and New Zealand Joint Replacement Registries. J Arthroplasty. 2020. PMID: 32620297. doi:10.1016/j.arth.2020.05.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。