十年随访:非骨水泥金属-聚乙烯全髋关节置换术患者队列金属离子水平升高
本研究对2009年接受Trident-Accolade非骨水泥金属-聚乙烯全髋关节置换术的患者进行随访,复测33例患者的血清钴和铬水平。结果显示无论股骨头尺寸如何,钴和铬水平随时间均显著升高(p < 0.001),但36 mm和40 mm组与28 mm组之间差异不显著;2例大尺寸股骨头患者因trunnion损坏行翻修术,2例40 mm组患者金属离子水平超过MHRA详细调查阈值。
要点
- 金属-聚乙烯全髋关节置换术后十年,所有模块化股骨头尺寸的血清钴和铬水平随时间显著升高(p < 0.001)。
- 36 mm和40 mm组与28 mm组相比,钴和铬升高未达统计学显著(36 mm vs 28 mm:p = 0.092/p = 0.191;40 mm vs 28 mm:p = 0.200/p = 0.091)。
- 2例较大尺寸股骨头患者因trunnion损坏行翻修术,2例40 mm组患者金属离子水平超过MHRA详细调查阈值。
核心结论
- 金属-聚乙烯 bearings 患者中,所有模块化股骨头尺寸的钴和铬水平随时间升高,2例患者离子水平超过MHRA失败阈值,另2例需翻修手术。
- 作者认为这些结果可能对患者长期随访和未来假体选择(尤其年轻患者)有临床意义。
研究设计与样本
- 对2009年接受Trident-Accolade非骨水泥金属-聚乙烯全髋关节置换术的既往研究患者进行随访,邀请复测钴和铬水平并提供Oxford Hip Score,共33例患者完成金属离子复测。
主要发现
- 33例患者复测金属离子,无论股骨头尺寸,钴和铬水平随时间均显著升高(p < 0.001)。
- 36 mm组与28 mm组比较,钴和铬升高未达统计学显著(分别为p = 0.092和p = 0.191);40 mm组与28 mm组比较亦未达统计学显著(分别为p = 0.200和p = 0.091)。
- 2例较大尺寸股骨头患者因trunnion损坏行翻修术;2例40 mm组患者金属离子水平超过MHRA详细调查阈值。
- 不同股骨头尺寸之间Oxford Hip Score无差异。
关键数值与推荐
- 血清钴和铬水平随时间比较:显著升高(p < 0.001)。
- 36 mm vs 28 mm:钴p = 0.092、铬p = 0.191;40 mm vs 28 mm:钴p = 0.200、铬p = 0.091,均未达统计学显著。
- 2例40 mm组患者金属离子水平超过MHRA详细调查阈值。
- Oxford Hip Score在不同股骨头尺寸间无差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 金属离子仅在33例患者中复测。
- 原文结论指出这些结果可能对长期随访和假体选择有临床意义,但未报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: We have previously demonstrated raised cobalt and chromium levels in patients with larger diameter femoral heads, following metal-on-polyethylene uncemented total hip arthroplasty. Further data have been collected, to see whether these associations have altered with time and to determine the long-term implications for these patients and our practice. METHODS: Patients from our previous study who underwent Trident-Accolade primary total hip arthroplasties using a metal-on-polyethylene bearing in 2009 were reviewed. Patients were invited to have their cobalt and chromium levels retested, and were provided an Oxford Hip Score. Serum ion levels were then compared between groups (28 mm, 36 mm, and 40 mm heads) and over time. RESULTS: Metal ion levels were repeated in 33 patients. When comparing the results of serum metal ion levels over time, regardless of head size, there was a significant increase in both cobalt and chromium levels (p < 0.001). Two patients with larger head sizes had undergone revision arthroplasty with evidence of trunnion damage at surgery. Two patients within the 40 mm subgroup had metal ion levels above the MHRA (Medicines and Healthcare Products Regulatory Agency) threshold for detailed investigation. The increase in cobalt and chromium, when comparing the 36 mm and 40 mm groups with those of the 28 mm group, was not significant (36 mm vs 28 mm; p = 0.092/p = 0.191; 40 mm vs 28 mm; p = 0.200/p = 0.091, respectively). There was no difference, between femoral head sizes, when comparing outcome as measured by the Oxford Hip Score. CONCLUSION: This study shows an increase in cobalt and chromium levels over time for all modular femoral head sizes in patients with metal-on-polyethylene bearings, with two patients demonstrating ion levels above the MHRA threshold for failure, and a further two patients requiring revision surgery. These results may have clinical implications regarding longer term follow-up of patients and future implant choice, particularly among younger patients. Cite this article: Bone Joint J 2020;102-B(7):832-837.
引用
- Dover C, Kuiper JH, Craig P, et al. Ten years on: increased metal ion levels in a cohort of patients who underwent uncemented metal-on-polyethylene total hip arthroplasty. Bone Joint J. 2020. PMID: 32600130. doi:10.1302/0301-620X.102B7.BJJ-2019-1372.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。