文献速递关节外科

现代广泛多孔涂层股骨柄用于全髋关节翻修术的长期结果

Long-Term Results of Revision Total Hip Arthroplasty Using a Modern Extensively Porous-Coated Femoral Stem.
PubMed 文献 · J Arthroplasty · 2020-06-25

本研究为长期回顾性分析,纳入2001至2006年间55例首次股骨柄翻修患者,使用现代非骨水泥广泛多孔涂层钴铬一体式股骨柄,平均随访13.2年。结果显示Harris髋关节评分、WOMAC指数和UCLA活动评分均较术前显著改善,54例(98%)获得稳定骨长入,无机械失败和股骨柄再翻修。

要点

  • 现代广泛多孔涂层钴铬一体式股骨柄翻修后平均随访13.2年,无机械失败和再翻修。
  • 54例(98%)患者影像学显示稳定骨长入,10例假体周围骨折全部骨愈合。
  • Harris髋关节评分从术前51.8±2.3改善至末次随访85.1±1.77(P<.001)。

核心结论

  • 使用现代广泛多孔涂层钴铬股骨柄进行股骨组件翻修,可获得优异的功能结果、影像学结果和长期生存率,且并发症极少。

研究设计与样本

  • 长期回顾性分析前瞻性收集的数据,纳入2001年至2006年间55例(55髋)首次股骨柄翻修患者,使用现代非骨水泥广泛多孔涂层钴铬一体式股骨柄,平均年龄66.4±9.3岁,女性36例(66%),男性19例(34%)。

主要发现

  • 翻修指征包括无菌性松动33例、假体周围感染13例、假体周围骨折10例。
  • 末次随访较术前Harris髋关节评分显著改善(85.1±1.77 vs 51.8±2.3,P<.001),WOMAC指数显著改善(17.6±0.77 vs 33.3±0.8,P<.001),UCLA活动评分显著改善(5.25±0.2 vs 2.7±0.36,P<.001)。
  • 54例(98%)患者影像学分析显示稳定骨长入,所有10例假体周围骨折患者均获得骨折骨愈合。
  • 2例患者发生术中假体周围骨折并采用线缆钢板系统治疗,无机械失败和股骨柄再翻修。
  • 1例患者诊断为深部感染,因严重内科合并症接受长期抑制性抗生素治疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of an extensively porous-coated uncemented cobalt-chrome monoblock femoral stem for revision total hip arthroplasty (THA) is well established with excellent mid-term results. The aim of this study is to report the long-term survivorship of these implants in femoral stem revisions. METHODS: This is a long-term retrospective review of prospectively collected data of 55 femoral stem revisions in 55 patients using a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem. All patients between 2001 and 2006 who underwent first time femoral stem revision with a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem were included. Harris Hip Score, Western Ontario and McMaster Universities Index, and University of California Los Angeles activity scores were recorded preoperatively and at latest follow-up. Radiographs were analyzed for evidence of loosening, subsidence, osteolysis, and bony union. This study included 55 patients, comprising of 36 females (66%) and 19 males (34%) with a mean age of 66.4 ± 9.3 years at the time of surgery. The mean time interval from index procedure was 9.8 ± 2.9 years. Mean time from revision THA to final follow-up was 13.2 ± 2.17 years with a minimum of 10 years of follow-up. RESULTS: Indications for revision included aseptic loosening (33), prosthetic joint infection (13), and periprosthetic fracture (10). Significant improvement in Harris Hip Score (85.1 ± 1.77 vs 51.8 ± 2.3, P < .001), Western Ontario and McMaster Universities Index (17.6 ± 0.77 vs 33.3 ± 0.8, P < .001), and University of California Los Angeles (5.25 ± 0.2 vs 2.7 ± 0.36, P < .001) scores were found at latest follow-up compared to preoperative. Fifty-four patients (98%) achieved stable bony ingrowth on radiographic analysis. All 10 patients treated for periprosthetic fractures achieved bony union of their fractures. Two patients suffered intraoperative periprosthetic fractures and were treated with a cable-plating system. There were no mechanical failures and no femoral stem re-revisions. One patient was diagnosed with a deep infection and was treated with chronic suppressive antibiotic therapy due to significant medical comorbidities. CONCLUSION: Revision of the femoral component with a contemporary extensively porous-coated cobalt-chrome femoral stem has excellent functional outcomes, radiographic outcomes, and long-term survivorship with minimal complications.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Wallace CN, Chang JS, Kayani B, et al. Long-Term Results of Revision Total Hip Arthroplasty Using a Modern Extensively Porous-Coated Femoral Stem. J Arthroplasty. 2020. PMID: 32713726. doi:10.1016/j.arth.2020.06.052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。