单髁膝关节置换术中影像学异常值和翻修的高患病率
该回顾性分析纳入单中心253例内侧固定平台与活动平台单髁膝关节置换术,由2名年均可完成14.2例内侧单髁置换的高流量关节置换专科医生实施。仅19.0%的UKA满足全部4项对线目标,仅11.9%同时满足全部对线与悬突目标;对线异常值和悬突是假体失败的重要危险因素,累积翻修率为14.2%。
要点
- 仅19.0%(48例)UKA满足全部4项对线目标,仅11.9%(30例)同时满足全部对线与悬突目标。
- 股骨冠状面、股骨矢状面、胫骨冠状面和胫骨矢状面对线异常值均与假体失败风险显著相关(p值均<0.05)。
- 后悬突失败率25.0%(p=0.006)和内悬突失败率38.2%(p<0.001)是显著危险因素,前悬突无统计学意义(10.0%,p=0.090)。
核心结论
- UKA翻修比例和对线异常值比例高于预期,即使在年均完成14.2例UKA的高流量关节置换专科医生中也是如此。
- 对线和悬突异常值是假体失败的显著危险因素。
研究设计与样本
- 回顾性分析单中心253例初次固定平台与活动平台内侧UKA,由2名高流量关节置换专科医生实施,其UKA占膝关节置换实践<10%,平均每名医生每年完成14.2例内侧UKA。
- 评估假体生存率,并影像学测量股骨冠状面(FCA)、股骨矢状面(FSA)、胫骨冠状面(TCA)和胫骨矢状面(TSA)角度以及假体悬突。
- 异常值定义:FCA偏离中立位>±10°,FSA屈曲>15°,TCA偏离中立位>±5°,TSA偏离7°>±5°;「远异常值」为额外偏离>±2°。
- 悬突异常值定义:前悬突>3 mm,后悬突>2 mm,内悬突>2 mm。
主要发现
- 失败UKA患者平均在3.7年(范围0.03至8.7年)接受翻修,累积翻修率为14.2%。
- Kaplan-Meier生存分析显示5年生存率为88.0%(95%CI=82.0%至91.0%),10年生存率为70.0%(95%CI=56.0%至80.0%)。
- 仅19.0%(48例)UKA满足全部4项对线目标,仅72.7%(184例)满足全部3项悬突目标,仅11.9%(30例)同时落在全部对线和悬突目标内。
- 与无对线或悬突误差的假体(失败率0%)相比,FCA异常值(失败率15.4%,p=0.036)、FSA异常值(16.2%,p=0.028)、TCA异常值(17.9%,p=0.020)和TSA异常值(15.2%,p=0.034)显著影响假体失败风险;远异常值同样如此(p<0.05)。
- 其他失败危险因素为后悬突(失败率25.0%,p=0.006)和内悬突(38.2%,p<0.001);前悬突不是显著危险因素(10.0%,p=0.090)。
关键数值与推荐
- 对线异常值定义:FCA>±10°偏离中立位,FSA>15°屈曲,TCA>±5°偏离中立位,TSA>±5°偏离7°;远异常值为额外>±2°。
- 悬突异常值定义:前悬突>3 mm,后悬突>2 mm,内悬突>2 mm。
- 证据等级:治疗性IV级。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Alignment outcomes and their impact on implant survival following unicompartmental knee arthroplasty (UKA) are unclear. The purpose of this study was to assess the implant survival and radiographic outcomes after UKA as well as the impact of component alignment and overhang on implant survival. METHODS: We performed a retrospective analysis of 253 primary fixed-bearing and mobile-bearing medial UKAs from a single academic center. All UKAs were performed by 2 high-volume fellowship-trained arthroplasty surgeons. UKAs comprised <10% of their knee arthroplasty practices, with an average of 14.2 medial UKAs per surgeon per year. Implant survival was assessed. Femoral coronal (FCA), femoral sagittal (FSA), tibial coronal (TCA), and tibial sagittal (TSA) angles as well as implant overhang were radiographically measured. Outliers were defined for FCA (>±10° deviation from neutral), FSA (>15° of flexion), TCA (>±5° deviation from neutral), and TSA (>±5° deviation from 7°). "Far outliers" were an additional >±2° of deviation. Outliers for overhang were identified as >3 mm for anterior overhang, >2 mm for posterior overhang, and >2 mm for medial overhang. RESULTS: Among patients with a failed UKA, revision was performed at an average of 3.7 years (range, 0.03 to 8.7 years). The cumulative revision rate was 14.2%. Kaplan-Meier survival analysis demonstrated 5 and 10-year survival rates of 88.0% (95% confidence interval [CI] = 82.0% to 91.0%) and 70.0% (95% CI = 56.0% to 80.0%), respectively. Only 19.0% (48) of the UKAs met target alignment for all 4 alignment measures, and only 72.7% (184) met all 3 targets for overhang. Only 11.9% (30) fell within all alignment and overhang targets. The risk of implant failure was significantly impacted by outliers for FCA (failure rate = 15.4%, p = 0.036), FSA (16.2%, p = 0.028), TCA (17.9%, p = 0.020), and TSA (15.2%, p = 0.034) compared with implants with no alignment or overhang errors (0%); this was also true for far outliers (p < 0.05). Other risk factors for failure were posterior overhang (failure rate = 25.0%, p = 0.006) and medial overhang (38.2%, p < 0.001); anterior overhang was not a significant risk factor (10.0%, p = 0.090). CONCLUSIONS: The proportions of UKA revisions and alignment outliers were greater than expected, even among high-volume arthroplasty surgeons performing an average of 14.2 UKAs per year (just below the high-volume UKA threshold of 15). Alignment and overhang outliers were significant risk factors for implant failure. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
引用
- Kazarian GS, Barrack TN, Okafor L, et al. High Prevalence of Radiographic Outliers and Revisions with Unicompartmental Knee Arthroplasty. J Bone Joint Surg Am. 2020. PMID: 32618922. doi:10.2106/JBJS.19.01277
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。