全因单纯髋臼翻修全髋关节置换术后不稳定仍是临床难题
回顾性分析2007至2017年本机构200例单纯髋臼翻修病例,189例(200髋)符合标准。术后不稳定率12%(24例),18.5%(37例)再次手术,不同股骨头尺寸组间无显著差异;术前不稳定史是术后不稳定的显著危险因素,受限内衬组不稳定率最高(36.4%,P=0.090)。
要点
- 单纯髋臼翻修术后不稳定率12%,再次手术率18.5%。
- 不同股骨头尺寸组间术后脱位或再手术无显著差异。
- 术前不稳定史是术后不稳定的显著危险因素(P=0.011和P=0.001)。
核心结论
- 当代单纯髋臼翻修仍伴随显著的不稳定率。
- 股骨头尺寸并非术后脱位或再手术的预测因素,而术前不稳定史与术后不稳定相关。
- 翻修使用受限内衬的患者失败率最高,仍是未解决的临床问题。
研究设计与样本
- 回顾性综述本机构2007至2017年间所有单纯髋臼翻修病例(n=200),随访不足一年者排除,最终189例(200髋)符合标准。
- 患者分为4个股骨头尺寸组:32 mm或以下、36 mm或以上、双动、受限内衬,比较体重指数、髋臼位置、既往翻修和后续再手术等因素。
主要发现
- 总体不稳定率为12%(24例),37例(18.5%)接受后续翻修,其中11例因复发不稳定。
- 不同组间术后脱位或再手术无显著差异。
- 使用受限内衬组术后不稳定率最高(36.4%,P=0.090)。
- 术前不稳定史是术后不稳定的显著危险因素,有无既往翻修史者分别P=0.011和P=0.001。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The purpose of this study is to (1) evaluate the rate of instability and reoperation after acetabular component-only revision, (2) compare instability rates across various head sizes, and (3) determine patient factors correlating with postoperative instability. METHODS: We retrospectively reviewed all isolated acetabular component revisions (n = 200) at our institution between 2007 and 2017. Patients with less than one-year follow-up were excluded. Patients were subdivided into 4 head size groups: (1) 32 mm or less, (2) 36 mm or more, (3) dual mobility, and (4) constrained liners. Factors including the body mass index, cup position, prior revision(s), and subsequent reoperation were compared across groups. RESULTS: 189 patients (200 hips) met the inclusion criteria. The overall rate of instability was 12% (n = 24), and 37 (18.5%) cases underwent subsequent revision, including 11 cases for recurrent instability. There was no significant difference in postoperative dislocation or reoperation for instability across the various groups. The use of a constrained liner trended toward the highest rate of postoperative instability (36.4%, P = .090). History of preoperative instability was a significant risk factor for postoperative instability with or without history of prior revision (P = .011 and P = .001, respectively). CONCLUSION: Contemporary isolated acetabular revision is still associated with significant rates of instability. Surprisingly, the head size was not a predictive factor for postoperative dislocation or reoperation, but a prior history of instability was associated with postoperative instability. Patients revised to a constrained liner experienced highest rates of failure and remain an unsolved clinical problem.
引用
- Stevenson KL, Fryhofer G, Hasenauer M, et al. Instability After All-Cause Acetabular-Only Revision Total Hip Arthroplasty Remains a Clinical Problem. J Arthroplasty. 2020. PMID: 32622714. doi:10.1016/j.arth.2020.06.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。