一体式锥形柄全髋关节置换术治疗发育不良髋关节:20年随访研究
这项回顾性研究纳入1993至1997年间接受全髋关节置换术的102例患者(135髋),评估非骨水泥Wagner Cone柄在发育不良髋中的生存率、临床与影像学结果。20年无菌性松动Kaplan-Meier生存率为97%(95%CI,94.4-99.6),Harris髋关节评分从43.4分升至86.4分(P<.0001),Merle d'Aubignè评分从8.4升至15(P<.0001)。作者认为一体式Wagner Cone柄是发育不良髋的可靠选择,长期生存率优异且临床与影像学结果良好。
要点
- 20年无菌性松动Kaplan-Meier生存率为97%(95%CI,94.4-99.6)。
- Harris髋关节评分从43.4分升至86.4分(P<.0001)。
- Merle d'Aubignè评分从8.4升至15(P<.0001)。
核心结论
- 作者认为一体式Wagner Cone柄是发育不良髋的可靠选择,长期生存率优异且临床与影像学结果良好。
研究设计与样本
- 回顾性研究,纳入1993至1997年间接受全髋关节置换术的102例患者(135髋),平均年龄51岁(范围21-73),最短随访20年。
- 按Crowe分类,I度38髋、II度41髋、III度37髋、IV度19髋。
主要发现
- 20年无菌性松动Kaplan-Meier生存率为97%(95%CI,94.4-99.6)。
- 平均Harris髋关节评分从43.4分(范围22-51)升至86.4分(范围39-100)(P<.0001)。
- 平均Merle d'Aubignè评分从8.4(范围4-13)升至15(范围5-18)(P<.0001)。
- 末次随访时平均加州大学洛杉矶分校活动评分和视觉模拟评分分别为4.53(范围1-9)和1.25(范围0-6)。
- 报告异位骨化17%、柄周围透亮线19.2%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total hip arthroplasty in patients with hip dysplasia is challenging as a result of complex anatomic deformities in the hip. The aim of the study was to evaluate the survivorship, the clinical and radiographic outcomes of cementless Wagner Cone stem in patients with dysplastic hip. METHODS: This retrospective study reports on 102 patients (135 hips) who have undergone total hip arthroplasty between 1993 and 1997. The mean age of patients was 51 years (range, 21-73). Minimum follow-up was 20 years. According to the Crowe classification, 38 hips presented dysplasia of grade I, 41 of grade II, 37 of grade III, and 19 of grade IV. RESULTS: Kaplan-Meier survivorship for aseptic loosening was 97% (95% confidence interval, 94.4-99.6) at 20 years. The average Harris hip score increased from 43.4 points (range, 22-51) to 86.4 points (range, 39-100) (P < .0001) and average Merle d'Aubignè score increased from 8.4 (range, 4-13) to 15 (range, 5-18) (P < .0001); at the last follow-up, average University of California at Los Angeles activity score and visual analog score were 4.53 (range, 1-9) and 1.25 (range, 0-6), respectively; 17% of heterotopic ossification and 19.2% of radiolucency lines around the stem were reported. CONCLUSION: Monoblock Wagner Cone stem is a reliable option in dysplastic hip with an excellent survivorship and good clinical and radiographic outcome in the long term.
引用
- La Camera F, Loppini M, Della Rocca A, et al. Total Hip Arthroplasty With a Monoblock Conical Stem in Dysplastic Hips: A 20-Year Follow-Up Study. J Arthroplasty. 2020. PMID: 32600818. doi:10.1016/j.arth.2020.05.069
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。