文献速递关节外科

莫氏锥度设计髋臼聚乙烯内衬脱位

Dissociation of Acetabular Polyethylene Liners With a Morse Taper Design.
PubMed 文献 · J Arthroplasty · 2020-07-01

研究回顾了655例使用特定莫氏锥度锁定机制模块化髋臼杯行初次全髋关节置换的病例,其中7例因聚乙烯内衬脱位接受翻修手术,脱位平均发生于术后73个月。2例接受同一髋臼杯内聚乙烯内衬更换的患者因再脱位需二次翻修。作者建议对此类髋臼系统长期随访中警惕患者主诉的卡顿或吱吱声,且内衬脱位后不应将新内衬置入同一髋臼壳。

要点

  • 655例中7例因内衬脱位翻修,平均术后73个月发生。
  • 4例患者急性起病,表现为新发髋痛或吱吱声。
  • 2例同一髋臼杯内更换内衬者因再脱位需二次翻修。

核心结论

  • 聚乙烯内衬脱位是莫氏锥度锁定模块化髋臼组件不常见但可能发生的并发症。
  • 作者建议对此类髋臼系统长期随访中警惕患者主诉的卡顿或吱吱声。
  • 作者建议内衬脱位治疗后不应将新内衬置入同一髋臼壳,因存在进一步脱位风险。

研究设计与样本

  • 资深作者实施了655例初次全髋关节置换,使用一种特定设计的髋臼组件,采用A类聚乙烯内衬与金属头关节搭配。
  • 回顾了因髋臼内衬脱位接受翻修手术的病例。

主要发现

  • 655例中7例因内衬脱位接受翻修手术。
  • 内衬脱位平均发生于术后73个月。
  • 患者表现为新发髋痛或吱吱声,其中4例急性起病。
  • 2例接受同一髋臼杯内聚乙烯内衬更换的患者因再脱位需二次翻修手术。

临床怎么用

  • 作者建议对此类髋臼系统长期随访中警惕患者主诉的卡顿或吱吱声。
  • 作者建议内衬脱位治疗后不应将新内衬置入同一髋臼壳,因存在进一步脱位风险。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Polyethylene liner dissociation is an uncommon complication of hip replacement. Dissociation has been associated with particular acetabular component designs. This study reviewed acetabular liner dissociations in a specific modular cup with a Morse taper locking mechanism that has not been previously reported. METHODS: The senior author performed 655 primary total hip arthroplasties with one particular design of acetabular component using Class A polyethylene liners and metal head articulation. Cases with revision surgery performed for acetabular liner dissociation were reviewed. RESULTS: Seven of 655 patients with this cup underwent revision surgery for a dissociated liner. Liner dissociation occurred at a mean of 73 months postoperatively. Patients presented with new-onset hip pain or squeaking, 4 of which developed symptoms acutely. Two patients treated with polyethylene liner exchange into the same cup required a second revision surgery for recurrent dissociation. CONCLUSION: Polyethylene liner dissociation is an infrequent but possible complication associated with modular acetabular components using a Morse taper locking. Providers should be vigilant with long-term follow-up of patients with this acetabular system for patient complaints of catching or squeaking. Patients treated for liner dissociation should not have a new liner placed into the same acetabular shell given the risk for further dissociation.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Shnaekel AW, Mayes WH, Stambough JB, et al. Dissociation of Acetabular Polyethylene Liners With a Morse Taper Design. J Arthroplasty. 2020. PMID: 32684399. doi:10.1016/j.arth.2020.06.068

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。