文献速递关节外科

全髋关节置换术后骨盆旋转是动态且多变的

Pelvic rotation after total hip arthroplasty is dynamic and variable.
PubMed 文献 · Bone Joint J · 2020-01-01

本研究为单中心既往短期研究的1年随访,评估91例全髋关节置换术(THA)患者中50例术前与术后1年站立位骨盆正位片上的骨盆比率变化及其对髋臼假体位置的影响。结果发现骨盆矢状面对线在THA术后是动态且多变的,这些变化持续至术后1年,改变了髋臼假体的方向。作者认为,基于术前功能位X线片个体化放置髋臼假体的外科医生应考虑骨盆旋转(以及假体前倾和外展)在术后1年发生变化。

要点

  • THA术后1年骨盆比率较术前下降(后倾)者占54.0%(27例),无显著变化者占34.0%(17例),升高(前倾)者占12.0%(6例)。
  • 骨盆比率变化对应外展误差5°至10°者占22.0%,>10°者占6.0%。
  • 骨盆比率变化对应前倾误差5°至10°者占22.0%,>10°者占44.0%。

核心结论

  • THA术后骨盆矢状面对线是动态且多变的,这些变化持续至术后1年,改变了髋臼假体的方向。
  • 基于术前功能位X线片个体化放置髋臼假体的外科医生应考虑骨盆旋转(以及假体前倾和外展)在术后1年发生变化。

研究设计与样本

  • 本研究为本机构既往短期研究的1年随访,使用既往研究的人群,对91例接受THA的患者评估影像学骨盆比率,其中50例可随访至少1年(中位数1.5年;四分位距1.1至2.0年)。
  • 术前及术后1年拍摄站立位骨盆正位X线片。
  • 骨盆比率定义为下骶髂(SI)关节至耻骨联合上缘的垂直距离与下骶髂关节间水平距离之比;根据骨盆比率变化确定髋臼假体位置的表观变化;至少5°的变化被认为有临床意义。

主要发现

  • 比较术前与术后1年X线片,骨盆比率下降(后倾)者占54.0%(27例),无显著变化者占34.0%(17例),升高(前倾)者占12.0%(6例)。
  • 骨盆比率变化对应外展误差5°至10°者占22.0%,>10°者占6.0%。
  • 骨盆比率变化对应前倾误差5°至10°者占22.0%,>10°者占44.0%。

临床怎么用

  • 作者认为,基于术前功能位X线片个体化放置髋臼假体的外科医生应考虑骨盆旋转(以及假体前倾和外展)在术后1年发生变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aims of this study were to determine the change in the sagittal alignment of the pelvis and the associated impact on acetabular component position at one-year follow-up after total hip arthroplasty (THA). METHODS: This study represents the one-year follow-up of a previous short-term study at our institution. Using the patient population from our prior study, the radiological pelvic ratio was assessed in 91 patients undergoing THA, of whom 50 were available for follow-up of at least one year (median 1.5; interquartile range (IQR) 1.1 to 2.0). Anteroposterior radiographs of the pelvis were obtained in the standing position preoperatively and at one year postoperatively. Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Apparent acetabular component position changes were determined from the change in pelvic ratio. A change of at least 5° was considered clinically meaningful. RESULTS: Pelvic ratio decreased (posterior tilt) in 54.0% (27) of cases, did not change significantly in 34.0% (17) of cases, and increased (anterior tilt) in 12.0% (6) of cases when comparing preoperative to one-year postoperative radiographs. This would correspond with 5° to 10° of abduction error in 22.0% of cases and > 10° of error in 6.0%. Likewise, this would correspond with 5° to 10° of version error in 22.0% of cases and > 10° of error in 44.0%. CONCLUSION: Pelvic sagittal alignment is dynamic and variable after THA, and these changes persist to the one-year postoperative period, altering the orientation of the acetabular component. Surgeons who individualize the acetabular component placement based on preoperative functional radiographs should consider that the rotation of the pelvis (and thus the component version and inclination) changes one year postoperatively. Cite this article: Bone Joint J 2020;102-B(7 Supple B):47-51.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Kazarian GS, Schloemann DT, Barrack TN, et al. Pelvic rotation after total hip arthroplasty is dynamic and variable. Bone Joint J. 2020. PMID: 32600205. doi:10.1302/0301-620X.102B7.BJJ-2019-1614.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。