文献速递关节外科

干骺端延长柄提高非骨水泥全膝关节置换术中的胫骨稳定性

Metaphyseal Stem Extension Improves Tibial Stability in Cementless Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-06-02

研究在合成骨模型上比较三种胫骨部件在循环加载下的微动:无柄非骨水泥组、带50毫米短柄非骨水泥组及无柄骨水泥对照组,每组承受5000次循环的60/40内外侧负荷分布。结果显示带柄非骨水泥组在前方区域的微动较无柄非骨水泥组显著降低,且与骨水泥组相似。结论认为短干骺端柄可显著减少非骨水泥胫骨托的微动。

要点

  • 带50毫米短柄的非骨水泥胫骨部件在前方区域微动显著低于无柄非骨水泥部件。
  • 带柄非骨水泥组在各循环次数下前方区域结果与骨水泥组相似。
  • 研究在合成泡沫骨模型中进行,采用生理性60/40内外侧负荷分布加载5000次循环。

核心结论

  • 在合成泡沫骨模型中,为龙骨加四钉设计的胫骨部件增加50毫米短干骺端柄,可显著减少非骨水泥胫骨托循环加载时的微动,效果与骨水泥植入物相似。

研究设计与样本

  • 研究使用同一全膝关节置换系统的三种胫骨部件变体,植入合成骨模型,采用生理性内外侧60/40负荷分布进行5000次循环测试。
  • 第1组为无柄非骨水泥胫骨部件;第2组为相同非骨水泥部件加50毫米短柄;第3组为无柄骨水泥胫骨部件作为金标准对照。

主要发现

  • 带短柄非骨水泥组(第2组)在前方区域的微动较无柄非骨水泥组(第1组)显著降低。
  • 带短柄非骨水泥组(第2组)在前方区域各循环次数下的结果与骨水泥组(第3组)相似。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The goal was to determine if the addition of a metaphyseal stem extension limits micromotion of a cementless tibial component during cyclic loading in primary total knee arthroplasty. The hypothesis tested was that the use of a 50-mm stem extension on a cementless tibial component would limit motion compared with an identical cementless component without a stem extension. METHODS: The study used 3 variations of a tibial component from the same total knee arthroplasty system. Group 1 consisted of a cementless tibial component without a stem extension. Group 2 used the same cementless component as group 1, but with the addition of a short 50-mm stem. Group 3 consisted of a cemented tibial component without a stem extension to serve as a "control" (gold standard). The tibial specimens were implanted into a synthetic bone model and tested using a physiological medial-lateral 60/40 load distribution for 5000 cycles. RESULTS: The results demonstrated a significant decrease in motion at the anterior region of the cementless stem extension (group 2) components compared with the cementless with no stem extension (group 1). The cementless with stem extension (group 2) demonstrated similar results at all cycles to the cemented (group 3) components at the anterior region. CONCLUSION: The addition of a short metaphyseal stem (50mm) to a keel plus 4-peg tibial component design provides a significant reduction in micromotion during cyclic loading of a cementless tibial baseplate in a synthetic foam bone model, similar to a cemented implant.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Morwood MP, Guss AD, Law JI, et al. Metaphyseal Stem Extension Improves Tibial Stability in Cementless Total Knee Arthroplasty. J Arthroplasty. 2020. PMID: 32600812. doi:10.1016/j.arth.2020.05.068

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。