文献速递关节外科创伤骨科

初次全髋关节置换术中抛光锥形滑配骨水泥股骨柄假体周围骨折翻修的风险因素:基于英格兰、威尔士、北爱尔兰和马恩岛国家关节登记系统的登记队列研究

Risk Factors for Revision of Polished Taper-Slip Cemented Stems for Periprosthetic Femoral Fracture After Primary Total Hip Replacement: A Registry-Based Cohort Study from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man.
PubMed 文献 · J Bone Joint Surg Am · 2020-01-01

该回顾性队列研究纳入国家关节登记系统中299,019例使用抛光锥形滑配骨水泥股骨柄的初次全髋关节置换,中位随访5.2年,其中1,055例因假体周围骨折行翻修。多变量Cox回归显示,短柄、高偏距、大股骨头、钴铬合金柄、椭圆形或圆形截面及低黏度骨水泥与钴铬合金柄组合等与假体周围骨折翻修风险升高相关,女性、增加柄长和陶瓷对聚乙烯负重面与风险降低相关。作者结论认为需进一步研究确认因果关系。

要点

  • 钴铬合金柄联合低黏度骨水泥的假体周围骨折翻修风险显著升高(HR 22.88)。
  • 圆形截面柄(HR 9.58)和椭圆形截面柄(HR 1.96)均与翻修风险升高相关。
  • 女性(HR 0.52)、增加柄长(HR 0.97/毫米)和陶瓷对聚乙烯负重面(HR 0.55)与风险降低相关。

核心结论

  • 短柄、高偏距、大股骨头、钴铬合金材质、椭圆形或圆形截面的抛光锥形滑配股骨柄与假体周围骨折翻修风险升高相关。
  • 钴铬合金柄联合低黏度骨水泥与假体周围骨折翻修风险大幅升高相关。
  • 需进一步研究确认因果关系。

研究设计与样本

  • 回顾性队列研究,纳入英格兰、威尔士、北爱尔兰和马恩岛国家关节登记系统中299,019例使用抛光锥形滑配骨水泥股骨柄的初次全髋关节置换,中位随访5.2年(四分位距3.1至8.2年)。
  • 采用多变量Cox生存回归分析估计各变量与假体周围骨折翻修的风险比(HR)。

主要发现

  • 299,019例中1,055例因假体周围骨折行翻修,中位翻修时间3.1年(四分位距1.0至6.1年)。
  • 平均年龄72±9.7岁,女性占64.3%(192,365例),美国麻醉医师协会(ASA)分级1或2级占82.6%(247,126例)。
  • 与翻修风险升高相关的变量:年龄增加(HR 1.02/岁)、术中骨折(HR 2.57,95%CI 1.42至4.66)、椭圆形截面(HR 1.96,95%CI 1.22至3.16)、圆形截面(HR 9.58,95%CI 2.29至40.12)、柄偏距增加(HR 1.07/毫米)、股骨头尺寸增加(HR 1.04/毫米)、2012至2016年行全髋关节置换(HR 1.45,95%CI 1.18至1.78)、钴铬合金柄(HR 6.7,95%CI 3.0至15.4)、钴铬合金柄联合低黏度骨水泥(HR 22.88,95%CI 9.90至52.85)。
  • 与翻修风险降低相关的变量:女性(HR 0.52,95%CI 0.45至0.59)、柄长增加(HR 0.97/毫米)、陶瓷对聚乙烯负重面(HR 0.55,95%CI 0.36至0.85)。

关键数值与推荐

  • 证据等级:治疗性III级。

局限性

  • 需进一步研究确认因果关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Total hip replacement (THR) with a cemented polished taper-slip (PTS) femoral stem has excellent long-term results but is associated with a higher postoperative periprosthetic femoral fracture (PFF) risk compared with composite beam stems. This study aimed to identify risk factors associated with PFF revision following THR with PTS stems. METHODS: In a retrospective cohort study, 299,019 primary THRs using PTS stems from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) were included, with a median follow-up of 5.2 years (interquartile range [IQR], 3.1 to 8.2 years). The adjusted hazard ratio (HR) of PFF revision was estimated for each variable using multivariable Cox survival regression analysis. RESULTS: Of 299,019 THR cases, 1,055 underwent revision for PFF at a median time of 3.1 years (IQR, 1.0 to 6.1 years). The mean age (and standard deviation) was 72 ± 9.7 years, 64.3% (192,365 patients) were female, and 82.6% (247,126 patients) had an American Society of Anesthesiologists (ASA) class of 1 or 2. Variables associated with increased PFF were increasing age (HR, 1.02 per year), intraoperative fracture (HR, 2.57 [95% confidence interval (CI), 1.42 to 4.66]), ovaloid (HR, 1.96 [95% CI, 1.22 to 3.16]) and round cross-sectional shapes (HR, 9.58 [95% CI, 2.29 to 40.12]), increasing stem offset (HR, 1.07 per millimeter), increasing head size (HR, 1.04 per millimeter), THR performed from 2012 to 2016 (HR, 1.45 [95% CI, 1.18 to 1.78]), cobalt-chromium stem material (HR, 6.7 [95% CI, 3.0 to 15.4]), and cobalt-chromium stems with low-viscosity cement (HR, 22.88 [95% CI, 9.90 to 52.85]). Variables associated with a decreased risk of PFF revision were female sex (HR, 0.52 [95% CI, 0.45 to 0.59]), increasing stem length (HR, 0.97 per millimeter), and a ceramic-on-polyethylene bearing (HR, 0.55 [95% CI, 0.36 to 0.85]). CONCLUSIONS: Increased risk of PFF revision was associated with PTS stems that are short, have high offset, are used with large femoral heads, are made of cobalt-chromium, or have ovaloid or round cross-sectional shapes. Large increases in PFF risk were associated with cobalt-chromium stems used with low-viscosity cement. Further study is required to confirm causation. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Lamb JN, Jain S, King SW, et al. Risk Factors for Revision of Polished Taper-Slip Cemented Stems for Periprosthetic Femoral Fracture After Primary Total Hip Replacement: A Registry-Based Cohort Study from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. J Bone Joint Surg Am. 2020. PMID: 32604382. doi:10.2106/JBJS.19.01242