文献速递关节外科创伤骨科

胫骨形状与尺寸可预测日本患者无骨水泥单髁膝关节置换术后胫骨平台骨折风险

Tibial shape and size predicts the risk of tibial plateau fracture after cementless unicompartmental knee arthroplasty in Japanese patients.
PubMed 文献 · Bone Joint J · 2020-01-01

这项多中心研究纳入174例日本患者的212例无骨水泥Oxford单髁膝关节置换,术前X线测量内侧髁间隆突线(MEL)并记录胫骨组件尺寸。总体骨折率8%,胫骨内侧平台非常悬突者OR 13,使用A/AA型极小组件者OR 7,两者兼有者OR 21;无上述两因素者骨折率仅1.4%。建议对极小组件或非常悬突的日本患者改用骨水泥固定。

要点

  • 总体胫骨平台骨折率为8%(17/212膝)。
  • 非常悬突的内侧胫骨平台与极小胫骨组件分别使骨折风险显著升高。
  • 两者兼有者骨折风险最高,建议此类日本患者改用骨水泥固定。

核心结论

  • 日本患者无骨水泥单髁膝关节置换术后胫骨平台骨折率较高。
  • 对需极小胫骨组件或存在非常悬突内侧胫骨平台的日本患者,建议采用骨水泥胫骨固定。
  • 其余69%的膝关节可安全使用无骨水泥固定,预期骨折率低。

研究设计与样本

  • 多中心研究,纳入6家医院的212例无骨水泥Oxford单髁膝关节置换,涉及174例患者。
  • 术前X线绘制内侧髁间隆突线(MEL),将MEL位于内侧胫骨皮质内侧定义为非常悬突的内侧胫骨平台。
  • 使用A/AA型胫骨组件定义为极小尺寸。

主要发现

  • 总体骨折率为8%(17/212膝)。
  • 非常悬突的内侧胫骨平台者骨折风险升高(OR 13;p < 0.001)。
  • 使用极小胫骨组件者骨折风险升高(OR 7;p < 0.001)。
  • 同时具有非常悬突内侧胫骨平台和极小胫骨组件者OR为21(p < 0.001)。
  • 既无非常悬突也无极小胫骨组件的147膝(69%)骨折率为1.4%(2/147膝)。

关键数值与推荐

  • 非常悬突的内侧胫骨平台:MEL位于内侧胫骨皮质内侧。
  • 极小胫骨组件:使用A/AA型胫骨组件。
  • 推荐对需极小胫骨组件或存在非常悬突内侧胫骨平台的日本患者使用骨水泥胫骨固定。
  • 其余69%的膝关节可使用无骨水泥固定。

临床怎么用

  • 术前X线绘制MEL线评估内侧胫骨平台是否非常悬突。
  • 记录计划使用的胫骨组件尺寸,识别是否需A/AA型极小组件。
  • 对存在非常悬突内侧胫骨平台或需极小胫骨组件的日本患者,选择骨水泥胫骨固定以降低骨折风险。
  • 对无上述两因素的日本患者,可继续使用无骨水泥固定。

局限性

  • 研究仅针对日本患者,结论外推至其他人群需谨慎。
  • 原文未报告随访时长、骨折的具体诊断标准及多因素校正细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia. METHODS: The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used. RESULTS: The overall rate of fracture was 8% (17 out of 212 knees). The rate was higher in knees with very overhanging condyles (Odds ratio (OR) 13; p < 0.001) and with very small components (OR 7; p < 0.001). The OR was 21 (p < 0.001) in those with both very overhanging condyles and very small components. In all, 69% of knees (147) had neither very overhanging nor very small components, and the fracture rate in these patients was 1.4% (2 out of 147 knees). Males had a significantly reduced risk of fracture (OR 0.13; p = 0.002), probably because no males required very small components and females were more likely to have very overhanging condyles (OR 3; p = 0.013). 31% of knees (66) were in males and in these the rate of fracture was 1.5% (1 out of 66 knees). CONCLUSION: The rate of tibial plateau fracture in Japanese patients undergoing cementless UKA is high. We recommend that cemented tibial fixation should be used in Japanese patients who require very small components or have very overhanging condyles, as identified from preoperative radiographs. In the remaining 69% of knees cementless fixation can be used. This approach should result in a low rate of fracture. Cite this article: Bone Joint J 2020;102-B(7):861-867.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Hiranaka T, Yoshikawa R, Yoshida K, et al. Tibial shape and size predicts the risk of tibial plateau fracture after cementless unicompartmental knee arthroplasty in Japanese patients. Bone Joint J. 2020. PMID: 32600131. doi:10.1302/0301-620X.102B7.BJJ-2019-1754.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。