文献速递运动医学骨质疏松与代谢性骨病

唑来膦酸显著改善大鼠慢性肩袖损伤修复后的骨微结构与生物力学性能

Zoledronic Acid Substantially Improves Bone Microarchitecture and Biomechanical Properties After Rotator Cuff Repair in a Rodent Chronic Defect Model.
PubMed 文献 · Am J Sports Med · 2020-06-16

本研究在大鼠慢性肩袖损伤模型中,于重建术后单次皮下注射唑来膦酸100 µg/kg,8周后评估肱骨头骨微结构与止点生物力学。结果显示干预组肱骨头骨体积分数与小梁数目更高,止点最大失败载荷更高,组织学可见骨形成增加。结论提示唑来膦酸可改善骨微结构与生物力学性能,但需临床验证。

要点

  • 唑来膦酸单次皮下注射可提高慢性肩袖修复大鼠肱骨头的骨体积分数与小梁数目。
  • 干预组止点最大失败载荷更高,且皮质厚度与最大失败载荷正相关。
  • 组织学显示唑来膦酸组骨形成增加,但结论需临床研究验证。

核心结论

  • 单次唑来膦酸治疗可改善大鼠慢性肩袖经骨重建后肱骨头的骨微结构并提高止点最大失败载荷。

研究设计与样本

  • 控制性实验室研究,32只雄性Sprague-Dawley大鼠行左侧冈上肌腱切断、延迟3周经骨肩袖重建,术后8周处死。
  • 大鼠随机分两组,重建后1天干预组单次皮下注射唑来膦酸100 µg/kg体重,对照组皮下注射1 mL生理盐水。
  • 每组12只行双肩微计算机断层扫描及冈上肌腱止点生物力学测试,每组4只行组织学分析。

主要发现

  • 干预组手术侧肱骨头外侧骨体积分数高于对照组(P = .005),内侧亦高于对照组(P = .010)。
  • 干预组手术侧肱骨头外侧小梁数目高于对照组(P = .004),内侧亦高于对照组(P = .001)。
  • 干预组手术侧止点最大失败载荷高于对照组(P < .001)。
  • 干预组皮质厚度与最大失败载荷呈正相关(r = 0.69;P = .026)。
  • 组织学评估显示干预组骨形成增加。

临床怎么用

  • 在慢性肩袖撕裂经骨重建后,可考虑单次唑来膦酸改善肱骨头骨微结构与止点力学强度,但需临床研究验证。

局限性

  • 研究为大鼠慢性缺损模型,样本量有限,结论需临床研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Bone mineral density at the humeral head is reduced in patients with chronic rotator cuff tears. Bone loss in the humeral head is associated with repair failure after rotator cuff reconstruction. Bisphosphonates (eg, zoledronic acid) increase bone mineral density. HYPOTHESIS: Zoledronic acid improves bone mineral density of the humeral head and biomechanical properties of the enthesis after reconstruction of chronic rotator cuff tears in rats. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 32 male Sprague-Dawley rats underwent unilateral (left) supraspinatus tenotomy with delayed transosseous rotator cuff reconstruction after 3 weeks. All rats were sacrificed 8 weeks after rotator cuff repair. Animals were randomly assigned to 1 of 2 groups. At 1 day after rotator cuff reconstruction, the intervention group was treated with a single subcutaneous dose of zoledronic acid at 100 µg/kg bodyweight, and the control group received 1 mL of subcutaneous saline solution. In 12 animals of each group, micro-computed tomography scans of both shoulders were performed as well as biomechanical testing of the supraspinatus enthesis of both sides. In 4 animals of each group, histological analyses were conducted. RESULTS: In the intervention group, bone volume fraction (bone volume/total volume [BV/TV]) of the operated side was higher at the lateral humeral head (P = .005) and the medial humeral head (P = .010) compared with the control group. Trabecular number on the operated side was higher at the lateral humeral head (P = .004) and the medial humeral head (P = .001) in the intervention group. Maximum load to failure rates on the operated side were higher in the intervention group (P < .001). Cortical thickness positively correlated with higher maximum load to failure rates in the intervention group (r = 0.69; P = .026). Histological assessment revealed increased bone formation in the intervention group. CONCLUSION: Single-dose therapy of zoledronic acid provided an improvement of bone microarchitecture at the humeral head as well as an increase of maximum load to failure rates after transosseous reconstruction of chronic rotator cuff lesions in rats. CLINICAL RELEVANCE: Zoledronic acid improves bone microarchitecture as well as biomechanical properties after reconstruction of chronic rotator cuff tears in rodents. These results need to be verified in clinical investigations.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Schanda JE, Keibl C, Heimel P, et al. Zoledronic Acid Substantially Improves Bone Microarchitecture and Biomechanical Properties After Rotator Cuff Repair in a Rodent Chronic Defect Model. Am J Sports Med. 2020. PMID: 32543880. doi:10.1177/0363546520926471

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。