高交联与压缩模塑聚乙烯胫骨垫片在后交叉韧带替代型全膝关节置换术年轻患者中的长期评估:既往报告的简明随访
结果显示CPE组7膝(2.3%)、HXLPE组6膝(2%)接受翻修,14年生存率两组分别为97.7%和98%(以任何原因再手术为终点),以机械失败再手术为终点均为98%,无骨溶解或垫片骨折,组间无差异。
要点
- 平均随访13.2年,CPE与HXLPE垫片翻修率分别为2.3%和2%。
- 14年生存率以任何再手术为终点分别为97.7%和98%,以机械失败为终点均为98%。
- 无膝关节发生骨溶解或胫骨聚乙烯垫片骨折,组间无差异。
核心结论
- 在后交叉韧带替代型全膝关节置换术年轻患者中,CPE与HXLPE胫骨垫片长期生存率均较高且组间无差异。
主要发现
- CPE组7膝(2.3%)、HXLPE组6膝(2%)接受假体翻修。
- 14年生存率以任何原因再手术为终点:CPE组97.7%(95%CI 94%-100%),HXLPE组98%(95%CI 94%-100%)。
- 14年生存率以机械失败再手术为终点:两组均为98%(95%CI 94%-100%)。
- 无膝关节发生骨溶解或胫骨聚乙烯垫片骨折,组间无差异。
关键数值与推荐
- 14年生存率以任何原因再手术为终点:CPE组97.7%(95%CI 94%-100%),HXLPE组98%(95%CI 94%-100%)。
- 14年生存率以机械失败再手术为终点:两组均为98%(95%CI 94%-100%)。
- 翻修率:CPE组2.3%(7膝),HXLPE组2%(6膝)。
- 骨溶解和胫骨聚乙烯垫片骨折发生率均为0。
临床怎么用
- 对于后交叉韧带替代型全膝关节置换术的年轻患者,CPE与HXLPE垫片均可提供良好的长期生存率并避免骨溶解和垫片骨折。
局限性
- 本研究为对既往报告的简明随访,原文未报告其他局限性信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The purpose of the present study was to determine the long-term clinical and radiographic results, survival rate, prevalence of osteolysis, and prevalence of fracture of the tibial polyethylene insert following total knee arthroplasty (TKA). Three hundred patients (600 knees) were included in this follow-up study. The mean age of the patients (and standard deviation) was 60.3 ± 4.3 years, and the mean duration of follow-up was 13.2 years (range, 12 to 14 years). Revision of the TKA prosthesis was performed in 7 knees (2.3%) with a compression-molded polyethylene (CPE) tibial insert and 6 knees (2%) with a highly cross-linked polyethylene (HXLPE) tibial insert. The rate of survival at 14 years was 97.7% (95% confidence interval [CI], 94%-100%) in the CPE group and 98% (95% CI, 94%-100%) in the HXLPE group with reoperation for any reason as the end point. The rate of survival at 14 years was 98% (95% CI, 94%-100%) in both groups with reoperation for mechanical failure as the end point. No knee had osteolysis or fracture of the tibial polyethylene insert. There were no between-group differences. LEVEL OF EVIDENCE:: Therapeutic Level I. See Instruction for Authors for a complete description of levels of evidence.
引用
- Kim YH, Park JW. Long-Term Assessment of Highly Cross-Linked and Compression-Molded Polyethylene Inserts for Posterior Cruciate-Substituting TKA in Young Patients: A Concise Follow-up of a Previous Report. J Bone Joint Surg Am. 2020. PMID: 32590398. doi:10.2106/JBJS.20.00261
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。