文献速递关节外科

胫骨托旋转与后倾增加冠状面力线异常风险

Tibial tray rotation and posterior slope increase risk for outliers in coronal alignment.
PubMed 文献 · Bone Joint J · 2020-01-01

研究通过膝关节置换计算机模型分析胫骨托轴向旋转对冠状面力线的影响。结果显示,切割导板轴向旋转可导致高达1.8°的内外翻力线异常;胫骨托轴向旋转导致冠状面力线异常风险显著增高,从15°外旋时的1.9°外翻到25°内旋时的超过3°内翻。结论认为轴向旋转异常会改变冠状面力线并增加力线异常发生率。

要点

  • 切割导板轴向旋转合并后倾可导致高达1.8°的冠状面力线异常。
  • 胫骨托轴向旋转异常使冠状面力线异常风险显著增高。
  • 冠状面力线随轴向旋转每度改变0.07°,随后倾每度改变0.22°。

核心结论

  • 胫骨切割导板方向和胫骨托轴向旋转异常会改变冠状面力线,并可能增加力线异常的发生率。

研究设计与样本

  • 构建膝关节置换计算机模型,使用虚拟切割导板在冠状面垂直方向切割胫骨。
  • 虚拟导板轴向旋转范围为内侧15°至外侧15°,后倾范围为0°至7°。
  • 测量轴向旋转(内旋25°至外旋15°)的胫骨托在标准前后位X线片上的冠状面力线。

主要发现

  • 切割导板轴向旋转导致内外翻力线异常高达1.8°(15°轴向旋转合并7°后倾时)。
  • 胫骨托轴向旋转异常导致冠状面力线异常风险显著增高,范围从15°外旋时的1.9°外翻到25°内旋时的超过3°内翻。
  • 冠状面力线改变与轴向旋转和后倾呈线性关系(线性回归,R² > 0.99)。

关键数值与推荐

  • 切割导板轴向旋转每度使冠状面力线改变0.07°。
  • 后倾每度使冠状面力线改变0.22°。

临床怎么用

  • 术中应关注胫骨托的轴向旋转和后倾,避免力线异常。
  • 标准前后位X线片可用于评估胫骨托轴向旋转对冠状面力线的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The extensive variation in axial rotation of tibial components can lead to coronal plane malalignment. We analyzed the change in coronal alignment induced by tray malrotation. METHODS: We constructed a computer model of knee arthroplasty and used a virtual cutting guide to cut the tibia at 90° to the coronal plane. The virtual guide was rotated axially (15° medial to 15° lateral) and with posterior slopes (0° to 7°). To assess the effect of axial malrotation, we measured the coronal plane alignment of a tibial tray that was axially rotated (25° internal to 15° external), as viewed on a standard anteroposterior (AP) radiograph. RESULTS: Axial rotation of the cutting guide induced a varus-valgus malalignment up to 1.8° (for 15° of axial rotation combined with 7° of posterior slope). Axial malrotation of tibial tray induced a substantially higher risk of coronal plane malalignment ranging from 1.9° valgus with 15° external rotation, to over 3° varus with 25° of internal rotation. Coronal alignment of the tibial cut changed by 0.07° per degree of axial rotation and 0.22° per degree of posterior slope (linear regression, R2 > 0.99). CONCLUSION: While the effect of axial malalignment has been studied, the impact on coronal alignment is not known. Our results indicate that the direction of the cutting guide and malalignment in axial rotation alter coronal plane alignment and can increase the incidence of outliers. Cite this article: Bone Joint J 2020;102-B(6 Supple A):43-48.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. D'Lima DP, Huang P, Suryanarayan P, et al. Tibial tray rotation and posterior slope increase risk for outliers in coronal alignment. Bone Joint J. 2020. PMID: 32475266. doi:10.1302/0301-620X.102B6.BJJ-2019-1533.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。