ICD-10编码在翻修全髋关节置换术中的不准确性及其对翻修数据的影响
该研究回顾性分析了2个大型学术医疗中心2015年10月1日至2019年7月3日期间的895例翻修全髋关节置换术(rTHA),比较ICD-10-PCS编码与手术记录,发现置换编码准确率仅22%,移除并置换编码准确率降至17%,但所有手术均有至少1个rTHA触发码可被AJRR正确捕获。
要点
- ICD-10-PCS编码对rTHA的准确率低:置换编码22%,移除并置换编码17%。
- 所有rTHA均有至少1个AJRR触发码,可被登记系统正确识别。
- 使用行政索赔数据库的ICD-10-PCS数据评估rTHA细节需谨慎。
核心结论
- ICD-10-PCS编码对rTHA的准确率低,但所有rTHA均有至少1个AJRR触发码,可被AJRR正确捕获。
- 使用ICD-10-PCS程序数据评估rTHA具体细节需谨慎,并应反对扩展ICD-10-PCS作为收集植入物生存和登记数据的手段。
研究设计与样本
- 回顾性研究,纳入2个大型学术医疗中心2015年10月1日至2019年7月3日期间的895例rTHA。
- 记录侧别和具体翻修组件,与每个手术使用的ICD-10-PCS编码比较,依据AJRR发布的编码指南确定准确性。
主要发现
- 置换编码准确率为22%(195/895)。
- 移除并置换编码准确率降至17%(152/895)。
- 所有手术均有至少1个rTHA触发码,可向AJRR正确表明发生了rTHA。
临床怎么用
- 临床医生和研究者应认识到ICD-10-PCS编码在rTHA中的不准确性,避免依赖行政索赔数据库评估rTHA具体细节。
- AJRR等登记系统仍可通过触发码捕获rTHA病例,但具体翻修细节的准确性有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The International Statistical Classification of Diseases, 10th Revision (ICD-10), was adopted by the United States on October 1, 2015 and expanded coding from 3800 codes with the International Statistical Classification of Diseases, Ninth Revision, procedure code system (ICD-9-PCS) to 73,000. The increase in number of codes was designed to create more accurate representations of procedures like revision total hip arthroplasties (rTHAs). However, many worry that the increased complexity leads to more inaccurate coding. The purpose of this study is to determine the accuracy of ICD-10-PCS coding for rTHA and discuss the implications on registry data. METHODS: The rTHA databases at 2 large, academic medical centers were retrospectively reviewed for all rTHAs between October 1, 2015 and July 3, 2019. The laterality and specific revised components were recorded and compared with the ICD-10-PCS codes used for each procedure. The accuracy of ICD-10-PCS codes relative to the surgical record was determined using coding guidelines published by the American Joint Replacement Registry (AJRR). RESULTS: Overall, 895 cases were reviewed. Replacement coding was 22% accurate (195 of 895). For removal and replacement coding, accuracy dropped to 17% (152 of 895). All procedures had at least 1 rTHA trigger code that would signify correctly to AJRR that an rTHA occurred. CONCLUSION: In this study, the percent of correctly coded rTHA was low. All rTHA procedures had at least 1 AJRR trigger code; therefore, an rTHA would have been appropriately captured by AJRR. But these inaccuracies should make one pause when using ICD-10-PCS procedural data to try to evaluate specific rTHA details from administrative claims databases and ward against expanding ICD-10-PCS as a means to collect implant survival and registry data.
引用
- Lygrisse KA, Roof MA, Keitel LN, et al. The Inaccuracy of ICD-10 Coding in Revision Total Hip Arthroplasty and Its Implication on Revision Data. J Arthroplasty. 2020. PMID: 32507451. doi:10.1016/j.arth.2020.05.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。