文献速递关节外科

动态透视评估全膝关节置换术中股骨半径渐变设计对日常活动关节运动学的影响

Videofluoroscopic Evaluation of the Influence of a Gradually Reducing Femoral Radius on Joint Kinematics During Daily Activities in Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-05-27

本研究采用移动透视技术(25 Hz,1 ms快门),对30例单侧后交叉韧带保留型全膝关节置换术后≥1年且疗效良好的受试者进行步态、下楼梯、深蹲及坐站等日常活动的运动学评估,比较股骨半径渐变设计(15例)与双半径设计(15例)的差异。结果显示两组在屈伸、内外旋及前后平移范围上相似,但双半径设计组在屈膝约30°时前后平移方向突然改变,而渐变半径设计组无此现象。结论表明渐变半径设计消除了双半径设计在体内日常活动中出现的 paradoxical sudden anterior translation。

要点

  • 渐变股骨半径设计消除双半径设计在屈膝30°时的矛盾性突然前移。
  • 两组胫股关节活动范围(屈伸、收展、旋转、前后平移)相似。
  • 移动透视可在体内评估全膝关节置换术后日常活动运动学。

核心结论

  • 渐变股骨半径设计在体内日常活动(包括步态和下楼梯)中消除了双半径设计在屈膝30°时出现的矛盾性突然前移。

研究设计与样本

  • 对30例单侧后交叉韧带保留型全膝关节置换术后≥1年且疗效良好的受试者进行移动透视评估,其中渐变半径设计15例、双半径设计15例。
  • 评估5个完整周期的平地行走、下楼梯(0.18米台阶)、深蹲及坐椅起立活动,采用移动透视(25 Hz,1 ms快门)并以2D/3D图像配准提取运动学数据。

主要发现

  • 两组屈伸、收展、内外旋及前后平移的胫股关节活动范围相似,但前后平移与屈曲的耦合模式不同。
  • 双半径设计组在屈膝约30°时前后平移方向突然改变,渐变半径设计组无此现象。

临床怎么用

  • 在全膝关节置换术中采用渐变股骨半径设计可能有助于避免双半径设计在屈膝30°附近出现的矛盾性突然前移。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Paradoxical anterior translation in midflexion is reduced in total knee arthroplasties (TKAs) with a gradually reducing femoral radius, when compared to a 2-radii design. This reduction has been shown in finite element model simulations, in vitro tests, intraoperatively, and recently also in vivo during a lunge and unloaded flexion-extension. However, TKA kinematics are task dependent and this reduction has not been tested for gait activities. METHODS: Thirty good outcome subjects (≥1 year postoperatively) with a unilateral cruciate-retaining TKA with a gradually reducing (n = 15) or dual (n = 15) femoral radius design were assessed during 5 complete cycles of level walking, stair descent (0.18-m steps), deep knee bend, and sitting down onto and standing up from a chair, using a moving fluoroscope (25 Hz, 1 ms shutter time). Kinematic data were extracted by 2D/3D image registration. RESULTS: Tibiofemoral ranges of motion for flexion-extension, abduction-adduction, internal-external rotation, and anteroposterior (AP) translation were similar for both groups, whereas the pattern of AP translation-flexion-coupling differed. The subjects with the dual-radii design showed a sudden change in direction of AP translation around 30° of flexion, which was not present in the subjects with the gradually reducing femoral radius design. CONCLUSION: Through the unique ability of moving fluoroscopy, the present study confirmed that the gradually reducing femoral radii eliminated the paradoxical sudden anterior translation at 30° present in the dual-radii design in vivo during daily activities, including gait and stair descent.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. List R, Schütz P, Angst M, et al. Videofluoroscopic Evaluation of the Influence of a Gradually Reducing Femoral Radius on Joint Kinematics During Daily Activities in Total Knee Arthroplasty. J Arthroplasty. 2020. PMID: 32564968. doi:10.1016/j.arth.2020.05.039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。