双叉保留型全膝关节置换术后深弓步与坐立活动的在体运动学
本研究纳入29例单侧双叉保留型全膝关节置换术(BCR TKA)患者,利用CT与透视成像系统在单腿深弓步和坐立测试中比较术侧与对侧膝关节的在体六自由度运动学。结果显示BCR TKA在终末屈曲时后向股骨平移和坐立时股骨后滚均显著小于对侧,内旋在部分高强度屈曲活动中也显著减小,提示其运动学并未完全重现。
要点
- BCR TKA在单腿深弓步终末屈曲时后向股骨平移显著小于对侧膝。
- BCR TKA在坐立测试中股骨后滚显著小于对侧膝。
- BCR TKA在高屈曲弓步和坐立中内旋显著减小,运动学未完全重现。
核心结论
- 当代BCR TKA设计在剧烈活动中表现出不对称的屈伸和内外部旋转运动学,提示其运动学并未完全重现。
研究设计与样本
- 研究纳入29例接受单侧BCR TKA的患者,使用经验证的计算机断层扫描和透视成像系统在单腿深弓步和坐立测试中评估在体六自由度运动学。
- 比较BCR TKA侧与对侧膝关节的运动学参数。
主要发现
- 单腿深弓步终末屈曲时,BCR TKA侧平均后向股骨平移为13 mm(SD 4),对侧膝为16.6 mm(SD 3.7),差异有统计学意义(p = 0.001)。
- 坐立测试中,BCR TKA侧平均股骨后滚为11.6 mm(SD 4.5),对侧膝为14.4 mm(SD 4.6),差异有统计学意义(p < 0.043)。
- 高屈曲弓步中,BCR TKA侧内旋为4°(SD 5.6°),对侧膝为6.5°(SD 6.1°),p = 0.051。
- 坐立测试中,BCR TKA侧内旋为4.5°(SD 6°),对侧膝为6.9°(SD 6.3°),p = 0.048。
临床怎么用
- 临床解读BCR TKA术后运动学时应认识到其在高强度活动中可能未完全重现对侧膝运动学。
- 未来需进一步研究患者因素、假体位置和设计对优化BCR TKA运动学的重要性。
局限性
- 原文未明确报告研究的局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The removal of the cruciate ligaments in total knee arthroplasty (TKA) has been suggested as a potential contributing factor to patient dissatisfaction, due to alteration of the in vivo biomechanics of the knee. Bicruciate retaining (BCR) TKA allows the preservation of the cruciate ligaments, thus offering the potential to reproduce healthy kinematics. The aim of this study was to compare in vivo kinematics between the operated and contralateral knee in patients who have undergone TKA with a contemporary BCR design. METHODS: A total of 29 patients who underwent unilateral BCR TKA were evaluated during single-leg deep lunges and sit-to-stand tests using a validated computer tomography and fluoroscopic imaging system. In vivo six-degrees of freedom (6DOF) kinematics were compared between the BCR TKA and the contralateral knee. RESULTS: During single-leg deep lunge, BCR TKAs showed significantly less mean posterior femoral translation (13 mm; standard deviation (SD) 4) during terminal flexion, compared with the contralateral knee (16.6 mm, SD 3.7; p = 0.001). Similarly, BCR TKAs showed significantly less mean femoral rollback (11.6 mm (SD 4.5) vs 14.4 mm (SD 4.6); p < 0.043) during sit-to-stand. BCR TKAs showed significantly reduced internal rotation during many parts of the strenuous flexion activities particularly during high-flexion lunge (4° (SD 5.6°) vs 6.5° (SD 6.1°); p = 0.051) and during sit-to-stand (4.5° (SD 6°) vs 6.9° (SD 6.3°); p = 0.048). CONCLUSION: The contemporary design of BCR TKA showed asymmetrical flexion-extension and internal-external rotation, suggesting that the kinematics are not entirely reproduced during strenuous activities. Future studies are required to establish the importance of patient factors, component orientation and design, in optimizing kinematics in patients who undergo BCR TKA. Cite this article: Bone Joint J 2020;102-B(6 Supple A):59-65.
引用
- Kwon YM, Arauz P, Peng Y, et al. In vivo kinematics of deep lunges and sit-to-stand activities in patients with bicruciate-retaining total knee arthroplasty. Bone Joint J. 2020. PMID: 32475273. doi:10.1302/0301-620X.102B6.BJJ-2019-1552.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。