文献速递关节外科创伤骨科

现代聚酯补片在全膝关节置换伸膝装置重建中的生物力学性能更优

Enhanced Biomechanical Performance of a Modern Polyester Surgical Mesh for Extensor Mechanism Reconstruction in Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-06-04

本研究通过材料试验机模拟正常步态下膝关节运动,比较聚丙烯补片(Marlex)与LARS补片的力学性能。结果显示LARS补片的极限拉伸载荷、刚度系数和滞后能量耗散显著更高,最大位移显著更小。LARS补片在力-位移测试中表现更优,可能对应临床更少失败和更长寿命。

核心结论

  • 与聚丙烯补片相比,LARS补片在力-位移测试中表现出更优的力学性能。

研究设计与样本

  • 研究采用材料试验机模拟正常人类步态下的膝关节运动,对聚丙烯补片(Marlex)和LARS补片进行力-位移数据比较。

临床怎么用

  • LARS补片增强的力学性能可能临床对应更少失败、更长寿命和更高抗塑性变形(伸膝滞后)能力。

局限性

  • 未来需评估这些补片用于伸膝装置重建时的生存率和临床结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Extensor mechanism (EM) disruption following total knee arthroplasty is a devastating postoperative complication. Reconstruction with a synthetic mesh is one treatment option, although the optimal mesh material remains unknown. This study sought to compare the mechanical properties of 2 mesh material types that can be used for EM reconstruction. METHODS: Mechanical properties of a polypropylene mesh (Marlex mesh) and Ligament Advanced Reinforcement System (LARS) mesh were compared using force-displacement data from a material testing machine simulating knee movement during normal human gait. Tension to failure/ultimate tensile load, stiffness coefficients, axial strain, and cyclic hysteresis testing were measured and calculated. RESULTS: Compared to polypropylene mesh, LARS mesh demonstrated a significantly higher mean ultimate tensile load (2223 N vs 1245 N, P = .002) and stiffness coefficient (255 N/mm vs 14 N/mm, P = .035) in tension to failure testing, and significantly more energy dissipation (hysteresis) in hysteresis testing (771 kJ vs 23 kJ; P ≤ .040). LARS mesh also demonstrated significantly less maximum displacement compared to the polypropylene mesh (9.2 mm vs 90.4 mm; P ≤ .001). CONCLUSION: Compared to polypropylene mesh, LARS mesh showed superior performance related to force-displacement testing. The enhanced mechanical performance of LARS mesh may correlate clinically to fewer failures, increased longevity, and higher resistance to plastic deformation (extensor lag). Future research should evaluate survivorship and clinical outcomes of these meshes when used for EM reconstruction.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Naveen NB, Deckard ER, Buller LT, et al. Enhanced Biomechanical Performance of a Modern Polyester Surgical Mesh for Extensor Mechanism Reconstruction in Total Knee Arthroplasty. J Arthroplasty. 2020. PMID: 32591232. doi:10.1016/j.arth.2020.05.072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。