模块化股骨翻修假体的结局及假体设计对下沉的影响

Outcomes of modular femoral revision implants and the effect of component design on subsidence.
PubMed 文献 · Bone Joint J · 2020-01-01

这项比较队列研究分析了65例锥形模块化(TM)股骨柄与35例多孔涂层圆柱形模块化(PCM)股骨柄翻修全髋关节置换的病例,平均随访7年。两组假体均在术后前3个月出现下沉然后稳定,TM组下沉频率58.7%高于PCM组48.8%但无统计学差异;PCM组下沉与扩展粗隆截骨(ETO)显著相关,ETO使用后PCM下沉率达85%。两组Oxford髋关节评分均显著改善。

要点

  • TM与PCM两种模块化翻修股骨柄均在术后前3个月下沉后稳定,临床结局均显著改善。
  • 整体下沉频率TM组58.7%与PCM组48.8%无显著差异(p=0.344)。
  • PCM假体下沉与ETO显著相关,ETO后PCM下沉率达85%,提示可考虑选用TM假体。

核心结论

  • TM与PCM模块化翻修股骨柄均会在股骨内下沉,但临床结局无差异。
  • 股骨完整时TM下沉更频繁;若行ETO则PCM下沉显著更多,建议选用TM假体。

研究设计与样本

  • 比较队列研究,纳入2006年4月至2018年5月连续接受翻修全髋关节置换并使用TM或PCM股骨柄的患者。
  • 共65例TM和35例PCM病例,比较临床与影像学评估并分析下沉危险因素。

主要发现

  • 平均随访7年(1至13年),两组下沉均发生于术后前3个月(p<0.001)后假体稳定。
  • TM组下沉58.7%(38/65),平均2.3 mm(SD 3.5 mm);PCM组48.8%(17/35),平均1.9 mm(SD 2.6 mm);p=0.344。
  • PCM组下沉与ETO显著相关(p<0.041);PCM组ETO使用7/35例,其中85%(6/7)出现下沉。
  • 两组最终平均Oxford髋关节评分(OHS)均显著改善(p<0.001)。

关键数值与推荐

  • TM组下沉率58.7%(38/65),平均下沉2.3 mm(SD 3.5 mm)。
  • PCM组下沉率48.8%(17/35),平均下沉1.9 mm(SD 2.6 mm),组间p=0.344。
  • PCM组ETO与下沉显著相关(p<0.041),ETO后PCM下沉率85%(6/7)。
  • 两组OHS最终均显著改善(p<0.001)。

临床怎么用

  • 股骨完整时TM与PCM假体均可使用,临床结局无差异。
  • 需行ETO时PCM假体下沉风险显著增高,建议选用TM假体。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Femoral revision component subsidence has been identified as predicting early failure in revision hip surgery. This comparative cohort study assessed the potential risk factors of subsidence in two commonly used femoral implant designs. METHODS: A comparative cohort study was undertaken, analyzing a consecutive series of patients following revision total hip arthroplasties using either a tapered-modular (TM) fluted titanium or a porous-coated cylindrical modular (PCM) titanium femoral component, between April 2006 and May 2018. Clinical and radiological assessment was compared for both treatment cohorts. Risk factors for subsidence were assessed and compared. RESULTS: In total, 65 TM and 35 PCM cases were included. At mean follow-up of seven years (1 to 13), subsidence was noted in both cohorts during the initial three months postoperatively (p < 0.001) then implants stabilized. Subsidence noted in 58.7% (38/65 cases) of the TM cohort (mean 2.3 mm, SD 3.5 mm) compared to 48.8% (17/35) of PCM cohort (mean 1.9 mm, SD 2.6 mm; p = 0.344). Subsidence of PCM cohort were significantly associated with extended trochanteric osteotomy (ETO) (p < 0.041). Although the ETO was used less frequently in PCM stem cohort (7/35), subsidence was noted in 85% (6/7) of them. Significant improvement of the final mean Oxford Hip Score (OHS) was reported in both treatment groups (p < 0.001). CONCLUSION: Both modular TM and PCM revision femoral components subsided within the femur. TM implants subsided more frequently than PCM components if the femur was intact but with no difference in clinical outcomes. However, if an ETO is performed then a PCM component will subside significantly more and suggests the use of a TM implant may be advisable. Cite this article: Bone Joint J 2020;102-B(6):709-715.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Abdelsamie KR, Elhawary I, Ali H, et al. Outcomes of modular femoral revision implants and the effect of component design on subsidence. Bone Joint J. 2020. PMID: 32475233. doi:10.1302/0301-620X.102B6.BJJ-2019-1366.R2