增量输入提升机器学习算法自动检测假体松动的能力
本研究基于697例2012至2018年间首次接受全髋或全膝关节翻修术患者的术前正侧位X线片及病史合并症信息,训练卷积神经网络模型从术前影像诊断假体松动。最终模型在独立测试集上准确率、敏感性和特异性分别为88.3%、70.2%和95.6%,翻修全髋病例准确率90.1%优于翻修全膝的85.8%。
要点
- 机器学习可从术前X线片检测假体松动,最终模型独立测试集准确率88.3%。
- 融合公开DenseNet模型、正侧位影像与病史信息可提升模型性能。
- 模型对翻修全髋病例准确率90.1%,优于翻修全膝病例的85.8%。
核心结论
- 机器学习可从X线片检测假体松动,使用经充分训练的公开算法并加入临床数据可提升其准确率。
- 该算法目前尚不足以作为独立的松动判定指标,但可作为临床决策的有用辅助。
研究设计与样本
- 研究纳入2012至2018年间在本机构首次接受全髋或全膝关节翻修术的697例患者。
- 收集术前正位和侧位X线片及病史和合并症信息,依据手术记录定义假体松动或固定。
- 训练一系列卷积神经网络模型从术前X线片预测术中松动诊断,并将最佳模型加入病史数据构建最终模型,在独立数据集上测试。
主要发现
- 仅以影像为输入从头构建的首个模型准确率为70%。
- 最终模型在独立测试数据集上准确率、敏感性和特异性分别为88.3%、70.2%和95.6%。
- 最终模型对翻修全髋病例准确率为90.1%,对翻修全膝病例准确率为85.8%。
临床怎么用
- 该算法目前可作为临床决策的辅助工具,但尚不能单独作为判断假体松动的指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aim of this study was to evaluate the ability of a machine-learning algorithm to diagnose prosthetic loosening from preoperative radiographs and to investigate the inputs that might improve its performance. METHODS: A group of 697 patients underwent a first-time revision of a total hip (THA) or total knee arthroplasty (TKA) at our institution between 2012 and 2018. Preoperative anteroposterior (AP) and lateral radiographs, and historical and comorbidity information were collected from their electronic records. Each patient was defined as having loose or fixed components based on the operation notes. We trained a series of convolutional neural network (CNN) models to predict a diagnosis of loosening at the time of surgery from the preoperative radiographs. We then added historical data about the patients to the best performing model to create a final model and tested it on an independent dataset. RESULTS: The convolutional neural network we built performed well when detecting loosening from radiographs alone. The first model built de novo with only the radiological image as input had an accuracy of 70%. The final model, which was built by fine-tuning a publicly available model named DenseNet, combining the AP and lateral radiographs, and incorporating information from the patient's history, had an accuracy, sensitivity, and specificity of 88.3%, 70.2%, and 95.6% on the independent test dataset. It performed better for cases of revision THA with an accuracy of 90.1%, than for cases of revision TKA with an accuracy of 85.8%. CONCLUSION: This study showed that machine learning can detect prosthetic loosening from radiographs. Its accuracy is enhanced when using highly trained public algorithms, and when adding clinical data to the algorithm. While this algorithm may not be sufficient in its present state of development as a standalone metric of loosening, it is currently a useful augment for clinical decision making. Cite this article: Bone Joint J 2020;102-B(6 Supple A):101-106.
引用
- Shah RF, Bini SA, Martinez AM, et al. Incremental inputs improve the automated detection of implant loosening using machine-learning algorithms. Bone Joint J. 2020. PMID: 32475275. doi:10.1302/0301-620X.102B6.BJJ-2019-1577.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。