文献速递关节外科

股骨近端成角畸形患者行转子切除术的全髋关节置换术

Total Hip Arthroplasty With Trochanteric Ostectomy for Patients With Angular Deformity of the Proximal Femur.
PubMed 文献 · J Arthroplasty · 2020-05-11

本研究评估了15例(17髋)股骨近端成角畸形患者接受转子切除术(内翻畸形切除大转子,外翻畸形切除小转子)后行非骨水泥全髋关节置换术的效果。平均随访7.1年,所有股骨柄均中立位对齐并实现骨长入稳定,无翻修;改良Harris髋关节评分从术前50分改善至末次随访81分,但术中4髋发生股骨骨折。

要点

  • 转子切除术有助于股骨近端内翻/外翻畸形患者中立位插入非骨水泥股骨柄。
  • 平均随访7.1年,所有股骨柄骨长入稳定,无翻修。
  • 术中4髋发生股骨骨折,术后11例轻度跛行、4例中度跛行。

核心结论

  • 转子切除术可使股骨近端内翻/外翻畸形患者中立位插入非骨水泥股骨柄,并获良好临床结果。

研究设计与样本

  • 单中心回顾性研究,纳入15例(17髋;内翻11髋,外翻6髋)股骨近端成角畸形患者,行非骨水泥全髋关节置换术并使用转子切除术,平均随访7.1年(范围2.0-15.5年)。

主要发现

  • 术中4髋发生股骨骨折;所有股骨柄均中立位对齐。
  • 末次随访外展肌力平均4.3级(范围3-5),11例轻度跛行、4例中度跛行;所有股骨柄骨长入稳定,无翻修。
  • 改良Harris髋关节评分从术前平均50分改善至末次随访平均81分。

临床怎么用

  • 对股骨近端内翻畸形可切除大转子、外翻畸形可切除小转子,以辅助非骨水泥股骨柄中立位插入。

局限性

  • 样本量小(15例17髋),为单中心回顾性研究,随访时间范围跨度大。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Total hip arthroplasty (THA) of patients with a proximal femoral deformity is technically demanding. This deformity poses the risk of femoral fracture or perforation; stem malposition; and failed stem fixation. To insert a femoral stem in neutral position with a good fit, we removed the greater trochanter in case of a varus deformity, and the lesser trochanter in case of valgus deformity, while performing THA. We aimed to evaluate stem position, implant stability, clinical results, and radiological changes after THAs using this technique. METHODS: Fifteen patients (17 hips; 11 varus hips and 6 valgus hips) underwent cementless THA using the trochanteric osteotomy technique in one institution. We evaluated procedure-specific complications: intraoperative femoral fracture, stem malposition, weakness of the abductor power and limp. Modified Harris Hip Score, radiological changes, and the stability of stems were assessed at a mean of 7.1 years of follow-up (range 2.0-15.5). RESULTS: Femoral fracture occurred during the insertion of the stem in 4 hips. All stems were aligned in neutral position. At the latest follow-up, the mean power of the abductor was 4.3 (range 3-5). Eleven patients had slight limp and 4 patients had moderate limp. All stems had bone-ingrown stability and no stem was revised. The mean modified Harris Hip Score improved from 50 points at the preoperative evaluation to 81 points at the final follow-up. CONCLUSION: The trochanteric excision enabled neutral insertion of cementless stem in patients with varus/valgus deformity of the proximal femur, and THA using this technique rendered favorable results.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kim JT, Kim HS, Lee YK, et al. Total Hip Arthroplasty With Trochanteric Ostectomy for Patients With Angular Deformity of the Proximal Femur. J Arthroplasty. 2020. PMID: 32473769. doi:10.1016/j.arth.2020.04.099

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。