文献速递小儿骨科关节外科

髋臼指数与中心边缘角测量:哪一髋臼标志更可靠?两种方法比较

Which Acetabular Landmarks are the Most Useful for Measuring the Acetabular Index and Center-edge Angle in Developmental Dysplasia of the Hip? A Comparison of Two Methods.
PubMed 文献 · Clin Orthop Relat Res · 2020-01-01

本研究纳入74例发育性髋关节发育不良(DDH)患者,比较以髋臼顶外侧骨性缘与髋臼眉弓外侧端为标志测量髋臼指数和中心边缘角的可靠性及对残余髋发育不良的预测能力。结果显示骨性缘法组内和组间可靠性更高,预测残余发育不良的曲线下面积更大;两标志重合比例随年龄增长而增加,3岁时以眉弓外侧端测量可能导致过度诊断。

要点

  • 以髋臼顶外侧骨性缘测量髋臼指数和中心边缘角的组内与组间可靠性均高于以髋臼眉弓外侧端测量。
  • 3岁时以骨性缘测量的髋臼指数和中心边缘角预测残余髋发育不良的AUC高于以眉弓外侧端测量。
  • 两标志重合比例从3岁至末次随访在DDH髋、对侧髋和对照髋均显著增加。

核心结论

  • 在闭合复位治疗的DDH患者中,3岁时以髋臼顶外侧骨性缘测量髋臼指数和中心边缘角,预测残余髋发育不良的可靠性高于以髋臼眉弓外侧端测量。
  • 早期使用髋臼眉弓外侧端测量可能导致残余髋发育不良的过度诊断和不必要治疗。

研究设计与样本

  • 回顾性诊断研究,纳入1985年2月至2006年7月接受全麻下闭合复位及石膏固定的DDH患者,最终74例(81%)具有完整术前和末次随访数据。
  • 另设26例对照(来自先天性特发性偏侧肥大患者),在3岁和大于8岁时拍摄髋关节正位X线片。
  • 采用组内相关系数(ICC)比较组内和组间可靠性,采用受试者工作特征曲线下面积(AUC)比较预测残余髋发育不良的能力。

主要发现

  • 骨性缘法测量中心边缘角的组内ICC为0.96(95%CI 0.94-0.98),组间ICC为0.88(95%CI 0.81-0.92);眉弓法分别为0.81(95%CI 0.70-0.88)和0.69(95%CI 0.55-0.79)。
  • 骨性缘法测量髋臼指数的AUC为0.88(95%CI 0.80-0.96),中心边缘角AUC为0.841(95%CI 0.748-0.933);眉弓法分别为0.776(95%CI 0.67-0.88)和0.72(95%CI 0.59-0.84),差异有统计学意义(p=0.03和p=0.01)。
  • 两标志重合比例从3岁至末次随访在DDH髋从37%(25/67)增至81%(54/67)(OR=8.8,95%CI 3.1-33.9,p<0.001),对侧髋从42%(28/67)增至85%(57/67)(OR=16.5,95%CI 4.2-141.9,p<0.001),对照髋从38%(10/26)增至88%(23/26)(OR=14,95%CI 2.1-592.0,p=0.001)。
  • DDH髋与对侧髋及对照髋的两标志重合比例在两个时间点均无差异。

关键数值与推荐

  • 治疗结果按Severin分级分为满意(I或II级)和不满意(III或IV级)。
  • 骨性缘法测量髋臼指数AUC 0.88,中心边缘角AUC 0.841;眉弓法测量髋臼指数AUC 0.776,中心边缘角AUC 0.72。
  • 骨性缘法中心边缘角组内ICC 0.96、组间ICC 0.88;眉弓法组内ICC 0.81、组间ICC 0.69。

临床怎么用

  • 在DDH闭合复位后的随访中,建议以髋臼顶外侧骨性缘作为测量髋臼指数和中心边缘角的标志,因其可靠性和预测残余发育不良的能力更高。
  • 避免在低龄儿童中仅依据髋臼眉弓外侧端测量结果诊断残余髋发育不良,以减少过度诊断和不必要治疗。

局限性

  • 为回顾性研究,部分患者失访(19%在8岁前失访)。
  • 对照组来自先天性特发性偏侧肥大患者,样本量较小(26例),且DDH组与对照组在侧别分布上存在差异。
  • 证据等级为Level III,诊断性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The acetabular index and center-edge angle are widely used radiographic parameters. However, the exact landmarks for measuring these parameters are not clearly defined. Although their measurement is straightforward when the lateral osseous margin of the acetabular roof coincides with the lateral end of the acetabular sourcil, where these two landmarks disagree, recommendations have differed about which landmark should be used. Using a radiographic parameter with high reliability for predicting residual hip dysplasia helps avoid unnecessary treatment. QUESTIONS/PURPOSES: We aimed to (1) compare two landmarks (the lateral osseous margin of the acetabular roof and the lateral end of the acetabular sourcil) for measuring the acetabular index and center-edge angle with respect to intraobserver and interobserver reliability and the predictability of residual hip dysplasia in patients with developmental dysplasia of the hip (DDH) and (2) evaluate longitudinal change in the acetabular edge's shape after closed reduction with the patient under general anesthesia. METHODS: Between February 1985 and July 2006, we performed closed reduction with the patient under general anesthesia as well as cast immobilization in 116 patients with DDH. To be included in this study, a patient had to have dislocated-type DDH. We excluded patients with a hip dislocation associated with neuromuscular disease, arthrogryposis, or congenital anomalies of other organs or systems (n = 9); hips that underwent osteotomy within 1 year since closed reduction (n = 8); hips that underwent open reduction because of re-dislocation after closed reduction (n = 4); and hips with Type III or IV osteonecrosis according to Bucholz-Ogden's classification (n = 4). Ninety-one patients were eligible. We excluded 19% (17 of 91) of the patients, who were lost to follow-up before they were 8 years old, leaving 81% (74 of 91 patients) with full preoperative and most-recent data. Ninety-seven percent (72 patients) were girls and 3% (two patients) were boys. The mean ± standard deviation age was 14.0 months ± 6.4 months (range 3-40 months) at the time of closed reduction and 12.1 years ± 2.3 years (range 8.0-16.0 years) at the time of the latest follow-up examination, the duration of which averaged 11 years ± 2.2 years (range 6.5-15.4 years). To investigate whether longitudinal change in the acetabular edge's shape differed among hips with DDH, contralateral hips, and control hips, we identified control participants after searching our hospital's database for patients with a diagnosis of congenital idiopathic hemihypertrophy from October 2000 to November 2006 who had AP hip radiographs taken at 3 years old and then at older than 8 years. From 29 patients who met these criteria, we randomly excluded two male patients to match for sex because girls were predominant in the DDH group. We excluded another female patient from the control group because of a hip radiograph that revealed unacceptable rotation. Eventually, 26 patients were assigned to the control group. Control patients consisted of 24 girls (92%) and two boys (8%). The demographic characteristics of control patients was not different from those of 67 patients with unilateral DDH, except for laterality (left-side involvement: 64% [43 of 67] in the DDH group versus 38% [10 of 26] in the control group; odds ratio 1.7 [95% confidence interval, 1.0-2.8]; p = 0.035). The acetabular index and center-edge angle at 3 years old were measured using the lateral osseous margin of the acetabular roof (AIB and CEAB) and the lateral end of the acetabular sourcil (AIS and CEAS). The treatment outcome was classified as satisfactory (Severin Grade I or II) or unsatisfactory (Grade III or IV). The intraclass correlation coefficient (ICC) was used to compare the intraobserver and interobserver reliability of each method. We compared the predictability of residual hip dysplasia of each method at 3 years old as a proxy using the area under the receiver operating characteristic (AUC) curve. To evaluate longitudinal change in the acetabular edge's shape, we compared the proportion of hips showing coincidence of the two landmarks between 3 years old and the latest follow-up examination. To investigate whether the longitudinal change in the acetabular edge's shape differs among hips with DDH, contralateral hips, and control hips, we compared the proportion of coincidence among the three groups at both timepoints. RESULTS: Intraobserver and interobserver reliabilities were higher for the CEAB (ICC 0.96; 95% CI, 0.94-0.98 and ICC 0.88; 95% CI, 0.81-0.92, respectively) than for the CEAS (ICC 0.81; 95% CI, 0.70-0.88 and ICC 0.69; 95% CI, 0.55-0.79, respectively). The AIB (AUC 0.88; 95% CI, 0.80-0.96) and CEAB (AUC 0.841; 95% CI, 0.748-0.933) predicted residual hip dysplasia better than the AIS (AUC 0.776; 95% CI, 0.67-0.88) and CEAS (AUC 0.72; 95% CI, 0.59-0.84) (p = 0.03 and p = 0.01, respectively). The proportion of hips showing coincidence of the two landmarks increased from 3 years old to the latest follow-up examination in hips with DDH (37% [25 of 67] to 81% [54 of 67]; OR = 8.8 [95% CI, 3.1-33.9]; p < 0.001), contralateral hips (42% [28 of 67] to 85% [57 of 67]; OR = 16.5 [95% CI, 4.2-141.9]; p < 0.001), and control hips (38% [10 of 26] to 88% [23 of 26]; OR = 14 [95% CI, 2.1-592.0]; p = 0.001). The proportion of coincidence in hips with DDH was not different from that in the contralateral hips and control hips at both timepoints. CONCLUSIONS: Measuring the acetabular index and center-edge angle at 3 years old using the lateral osseous margin of the acetabular roof has higher reliability for predicting residual hip dysplasia than that using the lateral end of the acetabular sourcil in patients with DDH treated with closed reduction. Measuring the acetabular index and center-edge angle at an early age using the lateral end of the sourcil may lead to overdiagnosis of residual hip dysplasia and unnecessary treatment. LEVEL OF EVIDENCE: Level III, diagnostic study.

来源:Clin Orthop Relat Res,查看原文。版权归原作者所有。

引用

  1. Shin CH, Yang E, Lim C, et al. Which Acetabular Landmarks are the Most Useful for Measuring the Acetabular Index and Center-edge Angle in Developmental Dysplasia of the Hip? A Comparison of Two Methods. Clin Orthop Relat Res. 2020. PMID: 32379138. doi:10.1097/CORR.0000000000001289

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。