高分辨率外周定量CT评估骨密度与骨微结构的指南
国际骨质疏松基金会、美国骨与矿物质研究学会和欧洲钙化组织学会联合工作组制定指南,规范高分辨率外周定量CT(HR-pQCT)的成像协议、术语、结果报告及精度误差因素,并比较两代扫描仪差异,以促进临床研究标准化。
要点
- 规范桡骨远端和胫骨HR-pQCT成像协议及操作者培训与质控。
- 统一术语和结果报告标准,考虑精度误差对纵向和多中心研究的影响。
- 比较两代HR-pQCT扫描仪及其他高分辨率CT系统的差异。
核心结论
- 该指南针对HR-pQCT成像技术和术语标准化需求,提供结果解读与报告指导,并讨论领域内未解决问题。
研究设计与样本
- 国际骨质疏松基金会、美国骨与矿物质研究学会和欧洲钙化组织学会联合工作组通过多年会议制定指南。
主要发现
- 指南涵盖桡骨远端和胫骨HR-pQCT标准化成像协议,强调质量控制和操作者培训的重要性。
- 指南提供标准化术语和结果报告建议。
- 指南讨论影响准确性和精度误差的因素,并考虑纵向和多中心研究设计。
- 指南比较两代扫描仪及其他高分辨率CT系统。
临床怎么用
- 临床研究采用HR-pQCT时应遵循本指南的成像协议、术语和报告标准以保证研究可比性。
- 纵向和多中心研究需考虑精度误差因素并按指南设计。
局限性
- 文中未系统报告指南制定所依据的具体证据等级或推荐强度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The application of high-resolution peripheral quantitative computed tomography (HR-pQCT) to assess bone microarchitecture has grown rapidly since its introduction in 2005. As the use of HR-pQCT for clinical research continues to grow, there is an urgent need to form a consensus on imaging and analysis methodologies so that studies can be appropriately compared. In addition, with the recent introduction of the second-generation HrpQCT, which differs from the first-generation HR-pQCT in scan region, resolution, and morphological measurement techniques, there is a need for guidelines on appropriate reporting of results and considerations as the field adopts newer systems. METHODS: A joint working group between the International Osteoporosis Foundation, American Society of Bone and Mineral Research, and European Calcified Tissue Society convened in person and by teleconference over several years to produce the guidelines and recommendations presented in this document. RESULTS: An overview and discussion is provided for (1) standardized protocol for imaging distal radius and tibia sites using HR-pQCT, with the importance of quality control and operator training discussed; (2) standardized terminology and recommendations on reporting results; (3) factors influencing accuracy and precision error, with considerations for longitudinal and multi-center study designs; and finally (4) comparison between scanner generations and other high-resolution CT systems. CONCLUSION: This article addresses the need for standardization of HR-pQCT imaging techniques and terminology, provides guidance on interpretation and reporting of results, and discusses unresolved issues in the field.
引用
- Whittier DE, Boyd SK, Burghardt AJ, et al. Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography. Osteoporos Int. 2020. PMID: 32458029. doi:10.1007/s00198-020-05438-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。