文献速递运动医学关节外科

关节镜下肩袖修复长期结果:单排与双排固定的随访对比研究

Long-term Results of Arthroscopic Rotator Cuff Repair: A Follow-up Study Comparing Single-Row Versus Double-Row Fixation Techniques.
PubMed 文献 · Am J Sports Med · 2020-05-11

该队列研究比较关节镜下肩袖修复中单排(SR)与双排(DR)固定技术的长期结果,平均随访12±1年。总体Constant评分保持稳定,但全层再撕裂率从2年的27%增至12年的45%,修复失败对临床结果有负面影响,两种固定技术在临床结果上无显著差异。

要点

  • 关节镜下肩袖修复单排与双排固定长期临床结果无显著差异。
  • 全层再撕裂率2年为27%,12年增至45%。
  • 修复失败对Constant评分有负面影响,并促进继发性盂肱骨关节炎进展。

核心结论

  • 关节镜下肩袖修复采用单排或双排固定技术均能获得良好的长期临床结果。
  • 修复失败率较高,对临床结果和继发性盂肱骨关节炎进展有负面影响。
  • 双排修复在长期随访中略微改善肌腱完整性,但未显示对单排修复的临床优越性。

研究设计与样本

  • 队列研究,证据等级3。
  • 2005至2006年间纳入40例症状性全层肩袖撕裂患者,行关节镜下肩袖修复。
  • 单排修复采用改良Mason-Allen缝线抓取技术(n=20),双排修复采用缝线桥固定技术(n=20)。
  • 主要结局指标为Constant评分,同时行超声评估肌腱完整性及X线评估继发性盂肱骨关节炎。

主要发现

  • 共27例患者完成随访,其中单排16例、双排11例,平均随访12±1年(范围11-14年)。
  • 随访期间5例患者接受翻修手术,最终22例纳入分析。
  • 全层再撕裂数增加:术后2年22例中6例(27%),术后12年20例中9例(45%)。

关键数值与推荐

  • 全层再撕裂率:2年27%(6/22),12年45%(9/20)。

临床怎么用

  • 关节镜下肩袖修复选择单排或双排固定均可获得良好的长期临床结果。
  • 应告知患者长期再撕裂率较高,且修复失败可能影响临床结果和关节炎进展。
  • 双排固定可能略微改善肌腱完整性,但未转化为临床优势。

局限性

  • 样本量较小,随访完成率有限(27/40)。
  • 5例患者接受翻修手术,最终仅22例纳入分析。
  • 为队列研究,证据等级3。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Arthroscopic rotator cuff repair (RCR) with suture anchor-based fixation techniques has replaced former open and mini-open approaches. Nevertheless, long-term studies are scarce, and lack of knowledge exists about whether single-row (SR) or double-row (DR) methods are superior in clinical and anatomic results. PURPOSE: To analyze long-term results after arthroscopic RCR in patients with symptomatic rotator cuff tears and to compare functional and radiographic outcomes between SR and DR repair techniques at least 10 years after surgery. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: Between 2005 and 2006, 40 patients with a symptomatic full-thickness rotator cuff tear (supraspinatus tendon tear with or without a tear of the infraspinatus tendon) underwent arthroscopic RCR with either an SR repair with a modified Mason-Allen suture-grasping technique (n = 20) or a DR repair with a suture bridge fixation technique (n = 20). All patients were enrolled in a long-term clinical evaluation, with the Constant score (CS) as the primary outcome measure. Furthermore, an ultrasound examination was performed to assess tendon integrity and conventional radiographs to evaluate secondary glenohumeral osteoarthritis. RESULTS: A total of 27 patients, of whom 16 were treated with an SR repair and 11 with a DR repair, were followed up after a mean ± SD period of 12 ± 1 years (range, 11-14 years). Five patients underwent revision surgery on the affected shoulder during follow-up period, which led to 22 patients being included. The overall CS remained stable at final follow-up when compared with short-term follow-up (81 ± 8 vs 83 ± 19 points; P = .600). An increasing number of full-thickness retears were found: 6 of 22 (27%) at 2 years and 9 of 20 (45%) at 12 years after surgery. While repair failure negatively affected clinical results as shown by the CS (P < .05), no significant difference was found between the fixation techniques (P = .456). In general, progressive osteoarthritic changes were observed, with tendon integrity as a key determinant. CONCLUSION: Arthroscopic RCR with either an SR or a DR fixation technique provided good clinical long-term results. Repair failure was high, with negative effects on clinical results and the progression of secondary glenohumeral osteoarthritis. While DR repair slightly enhanced tendon integrity at long-term follow-up, no clinical superiority to SR repair was found.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Plachel F, Siegert P, Rüttershoff K, et al. Long-term Results of Arthroscopic Rotator Cuff Repair: A Follow-up Study Comparing Single-Row Versus Double-Row Fixation Techniques. Am J Sports Med. 2020. PMID: 32391732. doi:10.1177/0363546520919120

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。