文献速递骨肿瘤关节外科

骨水泥模块化股骨近端假体「法国悖论」技术:影像学、功能与肿瘤学结局

Radiographic, Functional, and Oncologic Outcomes of Cemented Modular Proximal Femur Replacement Using the "French Paradox" Technique.
PubMed 文献 · J Arthroplasty · 2020-04-23

回顾性分析47例2000至2019年行股骨近端置换的患者,采用「法国悖论」骨水泥技术,评估股骨柄无菌性松动、功能、并发症及肿瘤学结局。中位随访44个月,股骨柄松动率低,MSTS评分61%、TESS评分72%,13例发生20次并发症,5例局部复发。结论认为该技术短中期可行。

要点

  • 「法国悖论」骨水泥技术用于股骨近端假体,短中期股骨柄无菌性松动率低。
  • 功能结局:末次随访MSTS评分61%、TESS评分72%。
  • 并发症常见(13例20次),5例局部复发,需权衡风险。

核心结论

  • 尽管并发症存在,骨水泥模块化股骨近端假体采用「法国悖论」技术显示良好的股骨假体生存率,短中期可行。

研究设计与样本

  • 回顾性综述47例2000至2019年行股骨近端置换的患者,由两名评估者使用ISOLS评分和Barrack标准评估股骨柄松动,平均随访44个月。

主要发现

  • 两名评估者ISOLS评分分别为86%±6%和84%±6%。
  • 第一评估者将2例股骨柄评为「可能松动」,第二评估者将其中1例评为「可能松动」。
  • 两名评估者分别发现16例(70%)和15例(65.4%)无髋臼侵蚀。
  • 末次随访平均MSTS评分61%,TESS评分72%。
  • 13例患者发生20次并发症,5例出现局部复发。

关键数值与推荐

  • 两名评估者ISOLS评分分别为86%±6%和84%±6%。
  • 末次随访平均MSTS评分61%,TESS评分72%。

临床怎么用

  • 对于股骨近端肿瘤行假体置换,可采用「法国悖论」骨水泥技术(紧密髓腔匹配与薄骨水泥层)以降低松动风险。

局限性

  • 回顾性设计,样本量47例,平均随访44个月,证据等级III级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Endoprostheses are frequently used in the management of tumors involving the proximal femur. Aseptic loosening is a common complication that has been linked to the cementing technique. The "French paradox" is well-known cementing technique in the arthroplasty literature. No previous reports have assessed loosening in proximal femur replacements using this technique. We examined rates of femoral stem aseptic loosening in proximal femur replacements, functional outcomes, complications, and oncologic outcomes. METHODS: We conducted a retrospective review of 47 patients who underwent proximal femur replacement between 2000 and 2019. Two reviewers evaluated preoperative and postoperative radiographs using the International Society of Limb Salvage scoring system and Barrack criteria for stem loosening. The acetabulum was evaluated according to the criteria of Baker et al. Functional outcomes were assessed using Musculoskeletal Tumor Society (MSTS) score and Toronto Extremity Salvage Score. The mean follow-up was 44 months. RESULTS: The mean International Society of Limb Salvage scores for the 2 reviewers were 86% ± 6% and 84% ± 6%. The first reviewer graded femoral stem loosening as "possibly loose" in 2 patients, one of whom was graded as possibly loose by the second reviewer. The 2 reviewers found no acetabular erosion in 16 (70%) and 15 (65.4%) patients, respectively. The mean Musculoskeletal Tumor Society score and Toronto Extremity Salvage Score at last follow-up were 61% and 72%, respectively. Twenty complications occurred in 13 patients, and 5 patients experienced local recurrence. CONCLUSION: Despite complications, we showed favorable femoral component survival rates. Cementing the proximal femur prosthesis with tight canal fit and thin cement mantle is a viable option for the short and medium term. LEVEL OF EVIDENCE: III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Nooh A, Alaseem A, Epure LM, et al. Radiographic, Functional, and Oncologic Outcomes of Cemented Modular Proximal Femur Replacement Using the "French Paradox" Technique. J Arthroplasty. 2020. PMID: 32418744. doi:10.1016/j.arth.2020.04.047

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。