标准骨水泥股骨柄用于股骨转子间骨折内固定失败后全髋置换
本研究纳入107例股骨转子间骨折内固定失败后行全髋置换的患者,均使用标准骨水泥股骨柄。平均随访7.4年,102例临床与影像学结果良好,5例一般;结论认为标准骨水泥柄可靠且经济,只要骨孔被骨水泥覆盖,无需以股骨髓腔直径两倍旁路远端螺钉孔。
要点
- 标准骨水泥股骨柄可用于股骨转子间骨折内固定失败后的全髋置换。
- 平均随访7.4年,102/107例结果良好,5例一般。
- 骨孔被骨水泥覆盖时,无需旁路远端螺钉孔。
核心结论
- 标准骨水泥股骨柄在这类病例中是可靠且经济有效的假体。
- 只要骨孔被骨水泥覆盖,无需以股骨髓腔直径两倍旁路远端螺钉孔。
研究设计与样本
- 研究纳入107例股骨转子间骨折内固定失败后行全髋置换的患者,共107髋。
- 失败原因包括固定失败67例、骨不连16例、股骨头缺血性坏死15例、创伤后骨关节炎9例。
- 患者中男性48例、女性59例,平均年龄66岁(范围58-81岁)。
- 全髋置换时取出失败的动力髋螺钉,螺钉孔用骨水泥封堵,所有病例均使用骨水泥标准柄股骨假体。
主要发现
- 平均随访7.4年(至少5年),102例临床与影像学结果良好,5例一般。
- 1例感染,需二期翻修关节置换。
- 2例术中出现股骨近端裂纹骨折,采用环扎钢丝处理。
- 2例术后早期脱位。
- 无患者出现晚期假体周围股骨骨折或假体松动。
临床怎么用
- 对股骨转子间骨折内固定失败后需行全髋置换者,可选用标准骨水泥股骨柄。
- 术中取出内固定后,用骨水泥封堵螺钉孔,无需为旁路远端螺钉孔而扩大髓腔处理。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total hip replacement (THR) after failed internal fixation of intertrochanteric femoral fractures is challenging. The aim of this study is to show the reliability of using standard cemented femoral stems in this operation. METHODS: This work included 107 THRs performed in 107 patients after failed treatment of intertrochanteric femoral fractures. The etiology of failure included 67 cases of failure of fixation, 16 cases of nonunion, 15 cases of avascular necrosis, and 9 cases of post-traumatic osteoarthritis. There were 48 males and 59 females. The mean age was 66 years (range 58-81). Failed dynamic hip screws were removed at the time of THR, and the screw holes were blocked with cement. All cases had cemented standard stem femoral prostheses. RESULTS: At an average 7.4 years with a minimum of 5 years of follow-up, 102 cases had good clinical and radiological outcomes and 5 cases had fair outcomes. One patient was infected and required 2 stages of revision arthroplasty. Two cases had intraoperative proximal femoral crack, and were treated by cerclage wires. Two patients had early postoperative dislocations. No patients had late periprosthetic femoral fractures or implant loosening. CONCLUSION: Standard cemented femoral stems are reliable and cost-effective prostheses in such cases. It is not necessary to bypass the distal screw hole by doubling the femoral canal diameter as long as the bone holes are covered by cement.
引用
- Morsi EMZ, Drwish AEE, Saber AM, et al. The Use of Standard Cemented Femoral Stems in Total Hip Replacement After Failed Internal Fixation of Intertrochanteric Femoral Fractures. J Arthroplasty. 2020. PMID: 32389407. doi:10.1016/j.arth.2020.04.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。