血浆纤维蛋白原在假体周围感染诊断及再植入时机判断中优于D-二聚体和纤维蛋白降解产物
该回顾性研究纳入136例翻修手术患者,分为无菌失败组、假体周围感染(PJI)组和再植入组,比较血浆纤维蛋白原、D-二聚体、纤维蛋白降解产物(FDP)及ESR、CRP对PJI诊断和再植入时机的价值。结果显示纤维蛋白原对PJI诊断有良好价值,并可提示二期关节置换再植入前的残留感染;D-二聚体和FDP对PJI诊断价值有限,不能用于确定再植入时机。
要点
- 血浆纤维蛋白原诊断PJI的AUC为0.848,阈值3.61 g/L。
- 血浆D-二聚体AUC为0.914,但研究结论认为其诊断PJI价值有限。
- 纤维蛋白原可提示二期置换再植入前的残留感染。
核心结论
- 血浆纤维蛋白原对PJI诊断具有良好价值,可作为二期关节置换再植入前残留感染的指标。
- 血浆D-二聚体和FDP对PJI诊断价值有限,不能用于确定再植入时机。
研究设计与样本
- 患者分为三组:无菌失败组(A组)、PJI组(B组)和再植入组(C组)。
- 构建受试者工作特征曲线评估血浆纤维蛋白原、D-二聚体、FDP、ESR和CRP对PJI诊断及再植入时机的价值。
主要发现
- B组所有生物标志物水平均显著高于A组(P < .05)。
- B组血浆纤维蛋白原、CRP和ESR值均显著高于C组(均P < .05)。
- 血浆纤维蛋白原、D-二聚体、FDP、CRP和ESR的曲线下面积分别为0.848、0.914、0.728、0.737和0.868。
关键数值与推荐
- 血浆纤维蛋白原、D-二聚体和FDP的阈值分别为3.61 g/L、0.41 mg/L和3.55 mg/L。
临床怎么用
- 血浆纤维蛋白原可用于辅助诊断PJI,并帮助判断二期关节置换再植入前是否存在残留感染。
- 不宜使用血浆D-二聚体或FDP来确定PJI再植入时机。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The accurate and timely diagnosis of periprosthetic joint infection (PJI) is challenging, and no single biomarker can definitively confirm infection before revision arthroplasty. The coagulation cascade has been linked closely to infection. This study was performed to determine the value of plasma d-dimer, plasma fibrinogen, and plasma fibrin degradation product (FDP) for the diagnosis of PJI and timing of reimplantation. METHODS: We retrospectively enrolled 136 patients who underwent revision surgery from January 2008 to December 2019. They were assigned to 3 groups: aseptic failure (group A), PJI (group B), and reimplantation (group C). Receiver operating characteristic curves were constructed to estimate the value of plasma fibrinogen, plasma d-dimer, plasma FDP, erythrocyte sedimentation rate (ESR), and serum C-reactive protein (CRP) for PJI diagnosis and reimplantation timing. RESULTS: All biomarker levels were significantly higher in group B than in group A (P < .05), and plasma fibrinogen, CRP, and ESR values were significantly higher in group B than in group C (all P < .05). The receiver operating characteristic curves showed that the areas under the curve of plasma fibrinogen, plasma d-dimer, plasma FDP, CRP, and ESR were 0.848, 0.914, 0.728, 0.737, and 0.868, respectively, and the threshold values for plasma fibrinogen, plasma d-dimer, and plasma FDP were 3.61 g/L, 0.41 mg/L, and 3.55 mg/L, respectively. CONCLUSION: Plasma fibrinogen exhibits good value for the diagnosis of PJI and can be an indicator of residual infection before reimplantation in 2-stage arthroplasty. Plasma d-dimer and FDP are of limited value for PJI diagnosis and cannot be used to determine the timing of reimplantation.
引用
- Wu H, Meng Z, Pan L, et al. Plasma Fibrinogen Performs Better Than Plasma d-Dimer and Fibrin Degradation Product in the Diagnosis of Periprosthetic Joint Infection and Determination of Reimplantation Timing. J Arthroplasty. 2020. PMID: 32376167. doi:10.1016/j.arth.2020.03.055