文献速递关节外科

纤维蛋白溶解标志物与CRP、ESR诊断假体周围感染的比较

Comparison of a Comprehensive Set of Fibrinolytic Markers With C-Reactive Protein and Erythrocyte Sedimentation Rate for the Diagnosis of Periprosthetic Joint Infection.
PubMed 文献 · J Arthroplasty · 2020-05-07

该回顾性研究纳入157例翻修患者,比较纤维蛋白溶解标志物与CRP、ESR对慢性假体周围感染(PJI)的诊断价值。结果显示纤维蛋白原诊断效能与CRP、ESR相近,曲线下面积为0.914。

要点

  • 纤维蛋白原诊断PJI的AUC为0.914,与CRP(0.924)相近。
  • 纤维蛋白原最佳阈值为3.56 g/L,灵敏度86.27%,特异度83.96%。
  • D-二聚体和FDP的AUC分别为0.784和0.808,诊断效能中等。

核心结论

  • 纤维蛋白溶解标志物对PJI诊断有较好支持价值,纤维蛋白原诊断效能与CRP和ESR相似。

研究设计与样本

  • 回顾性纳入2014年1月至2019年8月因无菌性松动(106例)或慢性PJI(51例)行翻修术的157例患者。
  • PJI定义采用肌肉骨骼感染学会(MSIS)标准,术前检测ESR、CRP、D-二聚体、FDP和纤维蛋白原。

主要发现

  • 慢性PJI组CRP、ESR、D-二聚体、FDP和纤维蛋白原水平均显著高于无菌性松动组(P < .001)。
  • 纤维蛋白原AUC为0.914,略低于CRP的0.924;FDP和D-二聚体AUC分别为0.808和0.784。

关键数值与推荐

  • 纤维蛋白原最佳阈值3.56 g/L,灵敏度86.27%,特异度83.96%。
  • D-二聚体最佳阈值1.22 mg/L,灵敏度66.67%,特异度85.85%。
  • FDP最佳阈值3.98 μg/mL,灵敏度72.55%,特异度80.19%。

临床怎么用

  • 纤维蛋白原可作为PJI的辅助诊断指标,其诊断效能与CRP和ESR相近。
  • D-二聚体和FDP也可提供一定的诊断支持,但效能中等。

局限性

  • 回顾性研究设计可能引入选择偏倚。
  • 单中心研究,样本量有限(157例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The diagnosis of periprosthetic joint infection (PJI), a serious complication after primary total joint arthroplasty, remains challenging. Recently, fibrinolytic activities have been shown to be closely related to infections and inflammation. However, data assessing the value of fibrinolytic markers for the diagnosis of PJI have been sparse until now. METHODS: We retrospectively enrolled 157 patients undergoing revision for aseptic loosening (n = 106, group A) or revision for chronic PJI (n = 51, group B) from January 2014 to August 2019. PJI was defined using the Musculoskeletal Infection Society criteria. Erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), D-dimer, fibrin degradation product (FDP), and fibrinogen were measured preoperatively. The diagnostic values of each biomarker were analyzed and compared using receiver operating characteristic curves, sensitivity, and specificity. RESULTS: Compared with group A, group B had significantly higher levels of CRP, ESR, D-dimer, FDP, and fibrinogen (P < .001). The area under the curve of fibrinogen was 0.914, which was slightly lower than that of CRP (0.924). FDP and D-dimer had area under the curve values of 0.808 and 0.784, respectively. The optimal threshold, sensitivity, and specificity were 3.56 g/L, 86.27%, and 83.96% for fibrinogen; 1.22 mg/L, 66.67%, and 85.85% for D-dimer; and 3.98 μg/mL, 72.55%, and 80.19% for FDP, respectively. CONCLUSION: Fibrinolytic markers provided promising diagnostic support for PJI, especially fibrinogen, which had a diagnostic efficiency similar to that of CRP and ESR.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Wang Y, Li Y, Qiao L, et al. Comparison of a Comprehensive Set of Fibrinolytic Markers With C-Reactive Protein and Erythrocyte Sedimentation Rate for the Diagnosis of Periprosthetic Joint Infection. J Arthroplasty. 2020. PMID: 32461024. doi:10.1016/j.arth.2020.04.096

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。