矩形股骨假体联合横向短缩截骨不植骨固定治疗Crowe 3/4型髋关节发育不良的临床与影像学结果
术后68%患者Harris髋关节评分优良,无差评,并发症率32%,骨不连1例(2%),平均下肢长度差0.8±0.6 cm,无假体松动或骨溶解。结论认为该技术可获得良好临床与影像学结果,截骨处植骨或固定并非必需。
要点
- Crowe 3/4型DDH行THA时,矩形股骨假体联合横向短缩截骨可不植骨、不固定截骨处。
- 术后68%患者Harris评分优良,无差评,并发症率32%,骨不连率2%。
- 平均下肢长度差0.8±0.6 cm,无患者假体下沉超过5 mm,无骨溶解或松动。
核心结论
- 采用矩形股骨假体与横向短缩截骨技术行THA,治疗Crowe 3和4型发育性髋关节发育不良可获得成功的临床与影像学结果。
- 截骨部位使用植骨或任何固定材料并非必需。
研究设计与样本
- 所有患者采用矩形股骨假体及横向短缩截骨,截骨处不植骨、不使用固定材料。
主要发现
- 术后Harris髋关节评分优良者占68%,无患者结果为差。
- 并发症发生率为32%,其中骨不连1例(2%)。
- 术后平均下肢长度差为0.8±0.6 cm。
- 无患者假体下沉超过5 mm。
- 影像学上,透亮线和致密线见于最多34%的患者,股骨近端骨萎缩见于最多96%的患者,但无假体骨溶解或松动。
关键数值与推荐
- 临床评估采用Harris髋关节评分和疼痛视觉模拟评分。
- 影像学评估包括下肢长度差、大转子下移程度、假体下沉、根据Gruen分区评估假体周围透亮线和致密线及骨萎缩或肥大、假体髓腔填充率。
临床怎么用
- 对于Crowe 3或4型发育性髋关节发育不良患者,采用矩形股骨假体联合横向短缩截骨行THA时,可考虑不植骨、不固定截骨处。
- 术后需关注并发症(本组发生率32%)及骨不连风险(本组2%),并评估下肢长度差和假体下沉。
局限性
- 原文未报告对照组或长期随访结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total hip arthroplasty (THA) involving shortening osteotomy for patients with Crowe type 3 or 4 dysplasia is a challenging surgical procedure. This study aims to demonstrate that rectangular femoral component use in anatomical reconstructions with THA and transverse shortening osteotomy yields successful results without the use of bone graft or any fixation material at the osteotomy site. METHODS: Fifty hips from 41 patients were identified retrospectively as per study objectives. All patients were evaluated using the Harris Hip Score and Visual Analog Scale for pain. Complications were reported. Radiological evaluation criteria were then evaluated, including leg length discrepancy, degree of trochanter caudalization and stem subsidence, radiolucent and radiodense lines for both components and bone atrophy or hypertrophy around the stem according to Gruen zones, and the canal fill ratio of the stem. RESULTS: Postoperative Harris Hip Score was excellent for 68% of patients. No patient had poor results. Complication rate was 32%. One patient had nonunion (2%). The mean postoperative leg length discrepancy was 0.8(±0.6) cm. No patient had a subsidence of more than 5 mm. Radiolucent and radiodense lines were present in up to 34% of patients, and bone atrophy was present in the proximal femur in up to 96% of patients. No patient had osteolysis or loosening in neither component. CONCLUSION: Successful clinical and radiological results can be obtained from Crowe type 3 and 4 dysplastic hips operated on with THA using a rectangular femoral component and transverse shortening osteotomy technique. The use of graft or any fixation material at the osteotomy site is not mandatory.
引用
- Kayaalp ME, Can A, Erdogan F, et al. Clinical and Radiological Results of Crowe Type 3 or 4 Dysplasia Patients Operated on With Total Hip Arthroplasty Using a Cementless Rectangular Femoral Component Without Fixating or Grafting the Transverse Osteotomy Site. J Arthroplasty. 2020. PMID: 32418747. doi:10.1016/j.arth.2020.04.045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。