机械辅助缝隙腐蚀致不良局部组织反应表现为全髋置换术后晚期不稳
这项多中心回顾性病例系列纳入17例金属-聚乙烯全髋置换术后晚期不稳患者,平均脱位2.7次、术后平均4.3年出现,翻修时均见不良局部组织反应(ALTR)和头颈模块腐蚀,多数更换为陶瓷头加钛套并放置限制性内衬,29.4%出现术后并发症。
要点
- 金属-聚乙烯全髋置换术后晚期反复脱位需警惕ALTR与MACC。
- 翻修时均见ALTR, modular头颈连接处可见腐蚀。
- 多数采用陶瓷头加钛套及限制性内衬翻修,并发症率29.4%。
核心结论
- 组件位置良好且无其他明显原因的反复不稳,应警惕ALTR作为潜在病因。
研究设计与样本
- 多中心回顾性病例系列,纳入17例(12例女性,平均年龄62.6岁,范围42-73)金属-聚乙烯全髋置换术后因ALTR和MACC出现晚期不稳的患者。
主要发现
- 患者平均脱位2.7次(范围1-6),于初次术后平均4.3年(范围0.4-17.0)出现。
- 血清金属水平(n=12)显示钴平均6.9 ng/mL(范围0.13-20.88),铬平均1.9 ng/mL(范围0.13-3.23)。
- 翻修于初次术后平均6.8年(范围2.1-19.4),每例均见ALTR,模块头颈连接处可见腐蚀。
- 15例(88.2%)行CoCr头更换为陶瓷头加钛套并放置限制性内衬。
- 5例(29.4%)出现术后并发症:腓总神经麻痹2例、假体周围感染2例、ALTR复发1例。
临床怎么用
- 对组件位置良好、无其他明确原因的反复脱位,应评估ALTR与MACC可能。
- 翻修时可考虑更换为陶瓷头加钛套并视情况使用限制性内衬。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Mechanically assisted crevice corrosion (MACC) at modular junctions can cause a spectrum of adverse local tissue reactions (ALTRs) in patients who have undergone total hip arthroplasty (THA). The purpose of this study is to describe the presentation, treatments, and related complications of a cohort of patients presenting with late instability following metal-on-polyethylene THA due to underlying MACC and ALTR. METHODS: This multicenter retrospective case series presents 17 patients (12 women, mean age 62.6, range 42-73) presenting with late instability secondary to ALTR and MACC. All patients had a metal (Cobalt Chrome)-on-polyethylene bearing surface. Patients experienced a mean 2.7 dislocations (range 1-6) at mean 4.3 years (range 0.4-17.0) following their index surgery. Serum metal levels (n = 12) demonstrated a greater elevation of cobalt (mean 6.9, range 0.13-20.88 ng/mL) than chromium (mean 1.9, range 0.13-3.23 ng/mL). RESULTS: Patients were revised for instability at a mean of 6.8 years (range 2.1-19.4) following their index surgery. ALTR was encountered in every case and the modular head-neck junction demonstrated visible corrosion. An exchange of the CoCr head to a ceramic head with a titanium sleeve and placement of a constrained liner was performed for a majority of patients (n = 15, 88.2%). Five patients (29.4%) had complications postoperatively including peroneal palsy (n = 2), periprosthetic joint infection (n = 2), and ALTR recurrence (n = 1). CONCLUSION: Recurrent instability in the setting of otherwise well-positioned THA components and without another obvious cause should raise concern for ALTR as a potential underlying etiology.
引用
- Hannon CP, Cotter EJ, Cooper HJ, et al. Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2020. PMID: 32389403. doi:10.1016/j.arth.2020.04.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。