文献速递关节外科

血清纤维蛋白原检测在假体周围关节感染诊断中表现良好

Serum Fibrinogen Test Performs Well for the Diagnosis of Periprosthetic Joint Infection.
PubMed 文献 · J Arthroplasty · 2020-04-30

这项回顾性研究纳入90例接受全膝或全髋关节置换翻修术的患者,其中53例确诊假体周围关节感染(PJI),37例为无菌性松动。结果显示纤维蛋白原(FIB)鉴别PJI与无菌性松动的AUC最高(0.928),灵敏度79.25%、特异度94.59%,且FIB在置入间隔物后显著下降。

要点

  • FIB鉴别PJI与无菌性松动的AUC为0.928,灵敏度79.25%,特异度94.59%。
  • FIB、CRP和ESR在PJI组均显著高于无菌性松动组(P < .001)。
  • 置入间隔物后PJI患者FIB水平显著降低(P < .001)。

核心结论

  • FIB是辅助诊断PJI的 adequate 检测,在区分PJI与无菌性松动方面不劣于CRP和ESR。
  • FIB在第一阶段手术后评估感染转归方面尤为有用。

研究设计与样本

  • 回顾性研究,纳入2015年1月至2019年8月接受全膝或全髋关节置换翻修术的90例患者。
  • PJI组53例(A组),无菌性松动组37例(B组)。
  • A组中仅21例记录了置入间隔物后血清FIB、CRP和ESR结果,并评估了这些患者的术后血清学标志物水平。

主要发现

  • A组FIB、CRP和ESR水平均显著高于B组(P < .001)。
  • 受试者工作特征曲线下面积以FIB最高,为0.928。
  • FIB分析的灵敏度为79.25%,特异度为94.59%。
  • 置入间隔物后PJI患者FIB水平显著降低(P < .001)。

关键数值与推荐

  • FIB鉴别PJI与无菌性松动的AUC为0.928,灵敏度79.25%,特异度94.59%。
  • FIB、CRP和ESR在PJI组与无菌性松动组间差异均有统计学意义(P < .001)。
  • 置入间隔物后FIB水平较术前显著下降(P < .001)。

临床怎么用

  • 可将血清FIB作为辅助诊断PJI的血清学指标,与CRP和ESR联合评估。
  • 在第一阶段手术后,可监测FIB水平变化以辅助评估感染转归。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Serum fibrinogen (FIB) is an acute-phase glycoprotein in the infection response that may stop excessive bleeding. The purposes of this study are to determine the value of FIB that can be used to differentiate between periprosthetic joint infection (PJI) and aseptic loosening of the prosthesis, and to determine the clinical significance of FIB for analyzing infection outcomes after first-stage surgery. METHODS: This retrospective study included 90 patients undergoing total knee arthroplasty or total hip arthroplasty revision from January 2015 to August 2019. PJI was confirmed in 53 patients (group A), and the other 37 patients were diagnosed with aseptic loosening of the prosthesis (group B). Only 21 patients in group A documented the results for serum FIB, C-reactive protein (CRP), and erythrocyte sedimentation rate (ESR) after spacer insertion, so the postoperative serological marker levels of the these patients were also assessed. RESULTS: The FIB, CRP, and ESR levels were significantly higher in group A than in group B (P < .001). The area under the receiver operating characteristic curve was highest for FIB at 0.928. Analyses of FIB levels revealed a sensitivity of 79.25% and a specificity of 94.59%. FIB levels were significantly lower in patients with PJI after spacer insertion (P < .001). CONCLUSION: FIB is an adequate test to aid in diagnosing PJI, and it is not inferior to CRP and ESR in distinguishing between PJI and aseptic loosening of the prosthesis. It is an especially useful tool in assessing infection outcomes after first-stage surgery.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Bin G, Xinxin Y, Fan L, et al. Serum Fibrinogen Test Performs Well for the Diagnosis of Periprosthetic Joint Infection. J Arthroplasty. 2020. PMID: 32446625. doi:10.1016/j.arth.2020.04.081

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。