文献速递脊柱外科小儿骨科

以C7-LIV连线椎体作为Lenke 1A型青少年特发性脊柱侧凸上端固定椎的多中心研究

Selecting the C7-LIV Line Vertebra as the Upper Instrumented Vertebra for Adolescent Idiopathic Scoliosis Lenke Type 1A Curves: Multicenter and a Minimum 2-Year Follow-up Study.
PubMed 文献 · Spine (Phila Pa 1976) · 2020-01-01

结果显示MSLV组术后2年C7铅垂线绝对值显著小于近端组和远端组,且矫形率与近端组相当。

要点

  • 以C7与LIV棘突中心连线确定MSLV作为UIV,可获更好躯干平衡。
  • MSLV组Cobb角矫正率65.3±1.3%,与近端组62.4±1.6%相当。
  • 术后2年MSLV组C7PL为0.5±0.4 cm,显著小于近端组和远端组。

核心结论

  • 在Lenke 1A型AIS后路脊柱融合术中,将MSLV设为UIV可获得更好的躯干平衡且不降低矫形率。

研究设计与样本

  • 按UIV与MSLV位置分为匹配组15例、近端组20例和远端组10例。

主要发现

  • 匹配组、近端组和远端组的Cobb角矫正率分别为65.3±1.3%、62.4±1.6%和52.8±6.8%,远端组较匹配组有较小矫正趋势(P=0.08)。
  • 术后2年C7铅垂线绝对值分别为0.5±0.4 cm、1.0±0.6 cm和1.3±0.9 cm,匹配组显著小于近端组和远端组(均P<0.05)。

关键数值与推荐

  • MSL定义为C7棘突中心与LIV棘突中心的连线,MSL近端首次接触的椎体定义为MSLV。
  • UIV位于MSLV为匹配组,位于MSLV近端为近端组,位于MSLV远端为远端组。

临床怎么用

  • 对于Lenke 1A型AIS,可依据C7-LIV连线选择MSLV作为UIV以优化术后躯干平衡。

局限性

  • 回顾性设计且证据等级为3级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Retrospective multicenter cohort study. OBJECTIVE: We evaluated a new upper instrumented vertebra (UIV) selection method that used the modified Shinshu line (MSL) to establish the selected UIV as the MSL vertebra (MSLV). SUMMARY OF BACKGROUND DATA: No reports have addressed optimal UIV selection according to the lower instrumented vertebra (LIV) for good trunk balance in Lenke 1A curves. METHODS: Forty-five consecutive patients (44 female, 14.4 ± 2.4 yrs) receiving posterior spinal fusion (PSF) for a Lenke 1A adolescent idiopathic scoliosis (AIS) curve were analyzed. We defined the novel MSL as the line between the center of the spinous process of C7 and that of the spinous process of the LIV. The vertebral body with which the MSL first contacted proximally was defined as the MSLV. The groups in which the UIV was at, proximal to, or distal to the MSLV were defined as the matched group (M-group; 15 cases [15 female], 14.7 ± 2.1 yrs), proximal group (P-group; 20 cases, [19 female], 15.0 ± 2.2 yrs), and distal group (D-group; 10 case [10 female], 14.8 ± 2.5 yrs), respectively. We measured Cobb angle, main thoracic (MT) curve correction rate, and C7 plumb line absolute value (C7PL) at pre- and 2 years postoperatively for comparisons using Dunnett test, with the M-group as the control. RESULTS: In the M-group, P-group, and D-group, the Cobb angle correction rate between pre- and postoperative time points were 65.3 ± 1.3%, 62.4 ± 1.6%, and 52.8 ± 6.8%, respectively, and comparable apart from a smaller correction tendency in the D-group versus the M-group (P = 0.08). At 2 years postoperatively, C7PL was 0.5 ± 0.4, 1.0 ± 0.6, and 1.3 ± 0.9 cm, respectively, and significantly smaller for the M-group (both P < 0.05). CONCLUSION: Better trunk balance were obtained without reducing correction rate by setting the novel MSLV as the UIV in PSF for Lenke type 1A curves. LEVEL OF EVIDENCE: 3.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Munakata R, Koseki M, Oba H, et al. Selecting the C7-LIV Line Vertebra as the Upper Instrumented Vertebra for Adolescent Idiopathic Scoliosis Lenke Type 1A Curves: Multicenter and a Minimum 2-Year Follow-up Study. Spine (Phila Pa 1976). 2020. PMID: 32355137. doi:10.1097/BRS.0000000000003509

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。