三维参数可指导凹侧棒预弯以矫正青少年特发性脊柱侧凸的胸椎后凸不足
结果显示凹侧棒连接脊柱后平均变平约20°,胸椎后凸相应增加约20°,RSD与三维胸椎后凸改善强相关,可指导凹侧棒预弯程度。
要点
- 凹侧棒置入后平均变平约20°,与三维胸椎后凸增加约20°相对应。
- 术前RSD与三维胸椎后凸变化强相关(r=0.796),可用于指导凹侧棒预弯。
- 凸侧棒角度由30±6°增至34±5°,胸椎主弯由57±8°降至11±6°。
核心结论
- 凹侧棒连接脊柱后平均变平约20°,胸椎后凸增加约20°,术前RSD与三维胸椎后凸恢复强相关,可指导凹侧棒弯曲程度以达到期望的胸椎后凸增加。
主要发现
- 凹侧棒角度由术前48±10°降至术后26±6°(P<0.001),平均变平约20°。
- 凸侧棒角度由30±6°增至34±5°(P<0.001)。
- 胸椎主弯由57±8°降至11±6°,顶椎旋转由16±5°降至5±6°(P<0.001)。
- 二维与三维胸椎后凸分别由19±14°和2±12°增至27±6°和22±5°(P<0.001)。
- 术前RSD与三维胸椎后凸变化强相关(P<0.001,r=0.796,R=0.633)。
关键数值与推荐
- RSD定义为术前凹侧棒轮廓至术前三维矢状面脊柱重建的最大垂直距离。
- 凹侧棒连接脊柱后平均变平约20°,胸椎后凸增加约20°,RSD与三维胸椎后凸变化r=0.796。
临床怎么用
- 术前可测量RSD以客观指导凹侧棒预弯程度,从而在青少年特发性脊柱侧凸矫形中实现期望的胸椎后凸增加。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Retrospective. OBJECTIVE: To evaluate the effect of preoperative rod shape on 3D spinal deformity correction. SUMMARY OF BACKGROUND DATA: Differential rod contouring is a surgeon-dependent process based on an estimate of 3D deformity correction sought and the flexibility of the spine. An objective measure to this otherwise subjective scoliosis correction technique is lacking. METHODS: A series of adolescent idiopathic scoliosis (AIS) patients with right, thoracic major curves, preoperative rod contour tracings, and EOS imaging was evaluated. All patients underwent posterior spinal fusion with 5.5 mm steel rods contoured prior to insertion. 3D reconstructions were generated pre- and postoperatively using sterEOS software (EOS Imaging) and imported into MATLAB (Mathworks) for analysis. A new measurement of the maximum perpendicular distance from the preinsertion concave rod contour to the preoperative 3D sagittal spinal reconstruction was defined as rod to 3D spine distance (RSD). Linear regressions were used to identify relationships between pre and postoperative parameters, including RSD and 3D thoracic kyphosis. RESULTS: Ninety-nine patients were included. Average preoperative concave rod angle decreased from (48 ± 10°) preoperatively to 26 ± 6° postoperatively (P < 0.001) for an average flattening of ∼20°. Average convex rod angle increased from 30 ± 6° to 34 ± 5° (P < 0.001). Average preoperative thoracic curve magnitude and apical vertebral rotation were 57 ± 8° and 16 ± 5° and decreased to 11 ± 6° and 5 ± 6° (P < 0.001). Average 2D and 3D thoracic kyphosis increased from 19 ± 14° and 2 ± 12° to 27 ± 6° and 22 ± 5° (P < 0.001). Preoperative RSD strongly correlated with 3D thoracic kyphosis change (P < 0.001, r = 0.796, R = 0.633). CONCLUSION: On average, the concave rod flattened ∼20° after connection to the spine. Similarly, kyphosis increased ∼20° following rod insertion. A strong correlation was identified between RSD and 3D thoracic kyphosis restoration. This novel 3D parameter can guide the degree of concave rod bend necessary to achieve a desired increase in thoracic kyphosis in AIS. LEVEL OF EVIDENCE: 2.
引用
- Kluck D, Newton PO, Sullivan TB, et al. A 3D Parameter Can Guide Concave Rod Contour for the Correction of Hypokyphosis in Adolescent Idiopathic Scoliosis. Spine (Phila Pa 1976). 2020. PMID: 32453225. doi:10.1097/BRS.0000000000003566
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。