可吸收螺钉与钛螺钉在前交叉韧带重建中的13年随机对照试验
BACKGROUND: Bioabsorbable screws for anterior cruciate ligament reconstruction (ACLR) have been a popular choice, with theoretical advantages in imaging and surgery.…
要点
- PLLA-HA螺钉与钛螺钉在前交叉韧带重建后2、5、13年的临床评分无差异。
- PLLA-HA螺钉在13年时完全或近乎完全吸收,但隧道体积基本不变且骨化轻微。
核心结论
- PLLA-HA螺钉与钛螺钉在前交叉韧带重建后2、5、13年临床结果等效。
- PLLA-HA螺钉13年时完全或近乎完全吸收,但隧道体积基本不变且骨化轻微。
研究设计与样本
- 使用腘绳肌腱自体移植进行前交叉韧带重建,在2、5、13年进行盲法评估。
主要发现
- 两组在2、5、13年的临床评分(IKDC、Lysholm、KT-1000)均无差异。
- 13年时PLLA-HA组在MRI或CT上显示螺钉完全或近乎完全吸收。
关键数值与推荐
- PLLA-HA螺钉在13年时完全或近乎完全吸收,隧道体积基本不变且骨化轻微。
临床怎么用
- 对于前交叉韧带重建,PLLA-HA螺钉可提供与钛螺钉等效的长期临床结果。
- PLLA-HA螺钉吸收后隧道体积基本不变且骨化轻微,可能有利于影像学评估。
局限性
- 原文未报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Bioabsorbable screws for anterior cruciate ligament reconstruction (ACLR) have been a popular choice, with theoretical advantages in imaging and surgery. Titanium and poly-L-lactic acid with hydroxyapatite (PLLA-HA) screws have been compared, but with less than a decade of follow-up. PURPOSE/HYPOTHESIS: The purpose was to compare long-term outcomes of hamstring autograft ACLR using either PLLA-HA screws or titanium screws. We hypothesized there would be no difference at 13 years in clinical scores or tunnel widening between PLLA-HA and titanium screw types, along with high-grade resorption and ossification of PLLA-HA screws. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: Forty patients undergoing ACLR were randomized to receive either a PLLA-HA screw or a titanium screw for ACL hamstring autograft fixation. Blinded evaluation was performed at 2, 5, and 13 years using the International Knee Documentation Committee score, Lysholm knee score, and KT-1000 arthrometer. Magnetic resonance imaging (MRI) was performed at 2 or 5 years and 13 years to evaluate tunnel volumes, ossification around the screw, graft integration, and cyst formation. Computed tomography (CT) of patients with PLLA-HA was performed at 13 years to evaluate tunnel volumes and intratunnel ossification. RESULTS: No differences were seen in clinical outcomes at 2, 5, or 13 years between the 2 groups. At 13 years, tibial tunnel volumes were smaller for the PLLA-HA group (2.17 cm3) compared with the titanium group (3.33 cm3; P = .004). By 13 years, the PLLA-HA group had complete or nearly complete resorption on MRI or CT scan. CONCLUSION: Equivalent clinical results were found between PLLA-HA and titanium groups at 2, 5, and 13 years. Although PLLA-HA screws had complete or nearly complete resorption by 13 years, tunnel volumes remained largely unchanged, with minimal ossification.
引用
- Sundaraj K, Salmon LJ, Heath EL, et al. Bioabsorbable Versus Titanium Screws in Anterior Cruciate Ligament Reconstruction Using Hamstring Autograft: A Prospective, Randomized Controlled Trial With 13-Year Follow-up. Am J Sports Med. 2020. PMID: 32302205. doi:10.1177/0363546520911024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。