现代多孔涂层髋臼系统在中早期全髋置换术中的前瞻性多中心研究
这项前瞻性多中心研究纳入148例因退行性髋病行初次全髋置换的患者,评估现代多孔涂层髋臼系统联合高交联聚乙烯或陶瓷内衬的5年安全性与有效性。5年随访仅1例因深部感染翻修,无松动翻修或影像学松动,总体生存率97.1%,患者报告结局显著改善。
要点
- 5年随访仅1例髋臼杯因深部感染翻修,无因松动翻修或影像学松动。
- 聚乙烯内衬成功率96.8%,陶瓷内衬100%,两者无差异(P=1.0)。
- 患者报告结局从术前至术后5年显著改善(P<.001)。
核心结论
- 5年多中心前瞻性研究显示,该髋臼系统联合交联聚乙烯或陶瓷内衬具有优异的生存率。
研究设计与样本
- 前瞻性非随机研究,在加拿大和美国8个中心开展,148例参与者接受现代多孔涂层髋臼壳。
- 主要结局为术后5年需翻修手术,次要结局包括生存分析、患者报告结局、影像学失败和术后不良事件。
主要发现
- 5年随访时1例髋臼杯因深部感染翻修,无因松动翻修,无影像学松动。
- 因任何原因再手术的总体生存率为97.1%。
- 聚乙烯内衬成功率96.8%,陶瓷内衬成功率100%,两种轴承表面成功率无差异(P=1.0)。
- 患者报告结局指标从术前至术后5年平均评分均显著改善(P<.001)。
关键数值与推荐
- 主要结局为术后5年需翻修手术。
- 因任何原因再手术的总体生存率为97.1%。
- 聚乙烯内衬成功率96.8%,陶瓷内衬成功率100%,两者无差异(P=1.0)。
临床怎么用
- 对于因退行性髋病行初次全髋置换的患者,可考虑使用该现代多孔涂层髋臼系统联合高交联聚乙烯或陶瓷内衬。
- 5年中期结果支持该髋臼系统在预防松动和翻修方面具有良好安全性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A contemporary, porous-coated acetabular implant designed for uncemented insertion was introduced in Europe and Australia in 2007. A similar previous acetabular system was found in several studies at 10 to 15-year follow-up to demonstrate accelerated polyethylene wear, osteolysis, and early failure. The current study was conducted to determine the midterm safety and effectiveness of this contemporary acetabular system using highly crosslinked polyethylene and ceramic liners at 5-year follow-up. METHODS: A prospective, nonrandomized study was conducted at 8 sites in Canada and the United States. All 148 study participants received a contemporary acetabular shell with proprietary porous coating. The primary outcome was the requirement for revision surgery at 5 years postoperatively. Secondary outcomes included a survival analysis, patient-reported outcome measures, radiographic failure, and postoperative adverse events. RESULTS: At 5-year follow-up there was 1 cup revised for deep infection. No cups were revised for loosening and none were found to be radiographically loose. The overall survival rate with reoperation for any reason was 97.1%. The success rate was 96.8% for polyethylene and 100% for ceramic with no difference in the success rate between either bearing surface (P = 1.0). The mean patient-reported outcome measures all improved significantly between preoperative and 5-year postoperative scores (P < .001). CONCLUSION: Results from this 5-year, multicenter, prospective study indicate excellent survivorship for this acetabular system when used with crosslinked polyethylene or ceramic bearing surfaces.
引用
- Wilson IR, Turgeon TR, Gascoyne TC, et al. Midterm Results of a Contemporary, Porous-Coated Acetabular System in Patients Undergoing Primary Total Hip Replacement for Degenerative Hip Disease: A Prospective, Multicenter Study. J Arthroplasty. 2020. PMID: 32229148. doi:10.1016/j.arth.2020.02.068
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。