文献速递关节外科创伤骨科

关节穿刺液量是否存在诊断假体周围感染的最佳 cutoff 值?

Is There an Optimal Cutoff for Aspiration Fluid Volume in the Diagnosis of Periprosthetic Joint Infection?
PubMed 文献 · J Arthroplasty · 2020-03-14

本研究回顾性分析 5 年内全髋和全膝关节翻修病例,评估术前穿刺液量与术中培养一致性。294 例纳入分析,45 例(15.3%)培养结果不一致;一致组平均穿刺液量显著高于不一致组(19.1 vs 10.2 mL,P = .02)。预测培养一致的最佳 cutoff 值:典型病原体 3.5 mL,缓慢生长病原体 12.5 mL。

要点

  • 穿刺液量越大,术前穿刺培养与术中培养一致性越高。
  • 缓慢生长病原体不一致组比例显著更高(52.4% vs 8.2%,P < .001)。
  • 预测培养一致的最佳 cutoff 值:典型病原体 3.5 mL,缓慢生长病原体 12.5 mL。

核心结论

  • 穿刺液量越高,术前穿刺培养与术中培养结果越可能一致。
  • 缓慢生长病原体的最佳穿刺液量 cutoff 值高于典型病原体。

研究设计与样本

  • 回顾性 review 了本机构 5 年内所有全髋和全膝关节翻修手术病例。
  • 排除穿刺时行关节灌洗、留置抗生素间隔物、疑似金属碎屑不良反应、穿刺液量记录不准确或无穿刺/术中培养的病例。
  • 最终 294 例符合纳入标准,采用 ROC 曲线评估穿刺液量预测培养一致性的价值。

主要发现

  • 共 review 857 例翻修病例,294 例纳入分析。
  • 45 例(15.3%)术前穿刺与术中培养结果不一致。
  • 一致组平均穿刺液量显著高于不一致组(19.1 vs 10.2 mL,P = .02)。
  • 不一致组中缓慢生长病原体比例显著高于一致组(52.4% vs 8.2%,P < .001)。

关键数值与推荐

  • 预测培养一致的最佳 cutoff 值:典型病原体为 3.5 mL。
  • 预测培养一致的最佳 cutoff 值:缓慢生长病原体为 12.5 mL。

临床怎么用

  • 临床行术前关节穿刺时,应尽量获取足够液量以提高培养与术中培养的一致性。
  • 对疑似缓慢生长病原体感染,应争取穿刺液量达到 12.5 mL 以上。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The diagnosis of periprosthetic joint infection is often challenging in the setting of low aspiration volumes, or in the presence of infection with a slow-growing organism. We sought to determine if an optimal threshold of aspiration fluid volume exists when cultures from the preoperative aspiration are compared to intraoperative cultures. METHODS: All revision total hip and knee arthroplasty procedures over 5 years at our institution were reviewed. Cases were excluded if they underwent joint lavage during aspiration, had an antibiotic spacer in place, were suspected of adverse local tissue reaction to metal debris, did not have an accurate aspiration volume recorded, or if there were no aspiration or operative cultures available. Receiver operating characteristic curves were used to evaluate aspiration volume for identifying cases with identical aspiration and culture results. RESULTS: A total of 857 revision cases were reviewed, among which 294 met inclusion criteria. There were 45 cases (15.3%) with discordant aspiration and operative cultures. The mean aspiration volume for identical cases was significantly higher than for discordant cases (19.1 vs 10.2 mL, P = .02). The proportion of slow-growing organisms was significantly greater among discordant compared to identical operative cultures (52.4% for discordant cases vs 8.2% for identical cases, P < .001). The optimal cutoff value for predicting identical cultures was 3.5 mL for typical organisms and 12.5 mL for slow-growing organisms. CONCLUSION: Aspiration cultures are more likely to correlate with intraoperative cultures with higher aspiration volumes, and the optimal aspiration volume is higher for slow-growing organisms.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Rockov ZA, Clarke HD, Grys TE, et al. Is There an Optimal Cutoff for Aspiration Fluid Volume in the Diagnosis of Periprosthetic Joint Infection? J Arthroplasty. 2020. PMID: 32269007. doi:10.1016/j.arth.2020.03.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。