双皮质接触预测翻修全髋关节置换术中模块化锥形股骨柄下沉
该回顾性队列研究纳入109髋(105例患者),随访至少2年,对象为Paprosky 3A/3B型股骨缺损行翻修全髋关节置换术并置入模块化锥形股骨柄者。多因素回归显示,双皮质接触距离减少(P < .001)和股骨柄长度≤155 mm(P < .001)与更高下沉率相关。研究提出双皮质接触至少20 mm的阈值以显著降低下沉率。
要点
- 双皮质接触距离减少与股骨柄下沉率增加独立相关(P < .001)。
- 股骨柄长度≤155 mm与更高下沉率相关(P < .001)。
- 双皮质接触至少20 mm是显著降低下沉率的阈值。
核心结论
- 增加股骨柄在股骨干部的双皮质接触及使用长度>155 mm的股骨柄可显著降低翻修全髋关节置换术中模块化锥形股骨柄的下沉率。
- 双皮质接触距离至少20 mm的阈值应理想地超过,以显著降低股骨柄在股骨管内的下沉风险。
研究设计与样本
- 回顾性队列研究,纳入109髋(105例患者,53男52女),随访至少2年。
- 所有翻修均为Paprosky 3A和3B型股骨缺损。
主要发现
- 多因素回归分析显示,双皮质接触距离减少(P < .001)与股骨柄下沉率增加相关。
- 股骨柄长度≤155 mm(P < .001)与更高下沉率相关。
- 研究证明双皮质接触20 mm是显著降低下沉率的新阈值。
关键数值与推荐
- 双皮质接触距离减少(P < .001)和股骨柄长度≤155 mm(P < .001)与更高下沉率独立相关。
- 双皮质接触至少20 mm的阈值需达到以显著降低下沉率。
临床怎么用
- 在翻修全髋关节置换术中,应争取股骨柄双皮质接触至少20 mm。
- 选择股骨柄长度>155 mm以降低下沉风险。
局限性
- 本研究为回顾性设计。
- 样本量有限(109髋)且随访至少2年。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We describe the intraoperative parameters that affect stem subsidence rates in tapered modular femoral stems for revision total hip arthroplasty (THA). We also determine the effect of the stem bicortical contact on subsidence rates and whether there is a minimum threshold bicortical contact that must be achieved to avoid the complication of subsidence. METHODS: This is a retrospective cohort study consisting of 109 hips in 105 patients (53 males and 52 females) at a minimum of 2 years of follow-up. All revisions were carried out for Paprosky type 3A and 3B femoral deficits. Clinical outcomes included the indication for revision, aseptic re-revision surgery, specifications of the stem inserted, and specifications of the femoral head and acetabular components implanted. Radiographic outcome measures included subsidence (mm) and bicortical contact (mm). RESULTS: Using multivariate regression analysis, 3 parameters were associated with an increased rate of stem subsidence. A reduced bicortical contact distance (P < .001) and a stem length of ≤155 mm (P < .001) were both associated with higher subsidence rates. We also demonstrated a novel threshold of 20-mm bicortical contact which must be achieved to significantly reduce subsidence rates in these modular femoral stems for revision THA. CONCLUSION: Subsidence rates of modular tapered femoral stems for revision THA can be significantly reduced by increasing the initial bicortical contact of the stem within the diaphysis and the overall length of the femoral stem >155 mm. We describe a minimum threshold bicortical contact distance of 20 mm that should ideally be exceeded to significantly reduce the risk of stem subsidence within the femoral canal.
引用
- Moriarty P, Sheridan GA, Wong L, et al. Bicortical Contact Predicts Subsidence of Modular Tapered Stems in Revision Total Hip Arthroplasty. J Arthroplasty. 2020. PMID: 32327285. doi:10.1016/j.arth.2020.03.047
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。