文献速递关节外科

模块化与一体式锥形开槽钛柄在翻修全髋关节置换术后的下沉比较

Subsidence Following Revision Total Hip Arthroplasty Using Modular and Monolithic Components.
PubMed 文献 · J Arthroplasty · 2020-03-12

本研究回顾了2013年1月至2018年3月间在一家城市骨科专科医院行翻修全髋关节置换术并使用模块化或一体式锥形开槽钛柄的186例患者(模块化106例,一体式80例)。结果显示模块化柄的下沉量显著大于一体式柄(3.9±2.6 vs 2.3±2.5 mm,P<.001),且模块化柄下沉>5 mm的比例显著更高(29.2% vs 11.3%,P<.001)。结论提示一体式锥形开槽钛柄可减少术后下沉的发生。

要点

  • 模块化柄下沉量显著大于一体式柄(3.9±2.6 vs 2.3±2.5 mm,P<.001)。
  • 模块化柄下沉>5 mm的比例显著更高(29.2% vs 11.3%,P<.001)。
  • 一体式锥形开槽钛柄可降低翻修全髋关节置换术后下沉风险。

核心结论

  • 一体式锥形开槽钛柄在翻修全髋关节置换术中显示出比模块化柄更少的下沉。

研究设计与样本

  • 回顾性研究,纳入2013年1月至2018年3月间在一家城市骨科专科医院行翻修全髋关节置换术并使用模块化或一体式锥形开槽钛柄的186例患者(模块化106例,一体式80例)。

主要发现

  • 模块化柄在最近一次影像学随访时的下沉量显著大于一体式柄(3.9±2.6 vs 2.3±2.5 mm,P<.001)。
  • 模块化柄下沉>5 mm的比例显著高于一体式柄(29.2% vs 11.3%,P<.001)。

临床怎么用

  • 骨科医生在翻修全髋关节置换术中选择模块化或一体式锥形开槽钛柄时,应权衡下沉风险与获益。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The ideal femoral component in revision total hip arthroplasty (rTHA) remains undetermined; however, tapered, fluted, titanium (TFT) stems are now widely used with favorable results in all types of revision scenarios. With both modular and monoblock TFT stem options, neither has been proven to be superior. Femoral stem subsidence has been linked to aseptic loosening, instability, and leg length discrepancy. This study aims to assess stem subsidence of modular and monoblock TFT stems at a single urban orthopedic specialty hospital within a tertiary academic medical center. METHODS: Electronic medical records of rTHAs performed between January 2013 and March 2018 utilizing modular and monoblock TFT stems were examined. Data collected included baseline demographics, surgical indication, femoral Paprosky classification, and stem subsidence at most recent follow up (3 months to 3 years). Two-sample t-tests and chi-squared tests were used for statistical analysis. RESULTS: A total of 186 patients (106 modular, 80 monoblock) were included in the analysis. Modular stems underwent significantly greater subsidence than monoblock stems at latest radiographic follow-up (3.9 ± 2.6 vs 2.3 ± 2.5 mm, P < .001). A significantly greater proportion of modular stems underwent >5 mm of subsidence at latest follow-up (29.2% vs 11.3%, P < .001). CONCLUSION: Monoblock TFT stems have displayed promising clinical results in prior studies, and now have been shown to decrease the incidence of postoperative subsidence. With the potential for stem subsidence to lead to aseptic loosening, limb length discrepancy, and instability, the orthopedic surgeon should weigh the risks and benefits of utilizing modular vs monoblock TFT stems in rTHA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Clair AJ, Gabor JA, Patel KS, et al. Subsidence Following Revision Total Hip Arthroplasty Using Modular and Monolithic Components. J Arthroplasty. 2020. PMID: 32253066. doi:10.1016/j.arth.2020.03.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。