文献速递关节外科

三极关节作为翻修全髋关节置换的高稳定轴承:成功率与失败风险因素

Tripolar Articulations as a "High Stability Bearing" for Revision Total Hip Arthroplasty: Success Rates and Risk Factors for Failure.
PubMed 文献 · J Arthroplasty · 2020-02-13

本研究回顾性分析了1994至2016年间67例使用非限制性三极关节行翻修全髋关节置换的病例,平均随访5.4年。结果显示2年、5年、10年无脱位生存率分别为88%、85%、74%,同时存在不稳史和展肌功能不全的患者10年无脱位生存率仅55%,而无上述危险因素者无脱位发生。

要点

  • 非限制性三极关节在翻修全髋关节置换中期随访中假体生存率尚可。
  • 同时存在不稳史和展肌功能不全者10年脱位风险接近50%。
  • 无不稳史且无展肌功能不全者未出现脱位。

核心结论

  • 非限制性三极关节在翻修全髋关节置换中期随访中假体生存率尚可,但在同时存在不稳史和展肌功能不全的患者中脱位风险显著升高。

研究设计与样本

  • 回顾性队列研究,纳入1994年至2016年间67例使用非限制性三极关节行翻修全髋关节置换的病例,平均随访5.4年。

主要发现

  • 2年、5年、10年无脱位生存率分别为88%、85%、74%,无再翻修生存率分别为91%、84%、65%。
  • 同时存在展肌功能不全和不稳史的患者2年、5年、10年无脱位生存率分别为77%、68%、55%,而无展肌功能不全和不稳史者无脱位发生。
  • 未观察到与轴承磨损相关的失败。

临床怎么用

  • 对于同时存在展肌功能不全和不稳史的翻修全髋关节置换患者,应考虑双动或限制性内衬等替代方案。

局限性

  • 本研究为回顾性设计,样本量有限,可能影响结果的普遍性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Unconstrained tripolar articulations have been theorized to increase hip stability. The purpose of this study is to report the performance of tripolar articulations in revision THA and identify factors associated with success and failure. METHODS: Between 1994 and 2016, 67 revision THAs were performed with an unconstrained tripolar articulation. Mean follow-up was 5.4 years. Patient charts were retrospectively reviewed emphasizing factors associated with risk of instability. There were 21 patients with neither a history of instability (HI) nor abductor insufficiency (AI), 20 patients with HI alone, 13 with AI alone, and 13 had both HI and AI. RESULTS: Twelve THAs sustained at least one postrevision dislocation at an average of 2.1 years. One bipolar dissociation occurred early (1.2 y). Nine hips had a re-revision to address these complications. Survival free from dislocation at 2, 5, and 10 years was 88%, 85%, and 74%, respectively. Survival free from re-revision at 2, 5, and 10 years was 91%, 84%, and 65%, respectively. Patients with combined AI and HI had the worst survivorship free from dislocation at 2, 5, and 10 years (77%, 68%, and 55%), respectively. In contrast, patients with neither HI nor AI experienced zero dislocations. There were no failures associated with bearing wear. CONCLUSION: Off-the-shelf tripolar articulations were associated with reasonable survival at midterm follow-up. In patients with both AI and HI, the risks and benefits of alternative options such as dual mobility or constrained liners should be explored as the risk of dislocation at 10 years approached 50%.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Goldman AH, Thompson JC, Berry DJ, et al. Tripolar Articulations as a "High Stability Bearing" for Revision Total Hip Arthroplasty: Success Rates and Risk Factors for Failure. J Arthroplasty. 2020. PMID: 32144007. doi:10.1016/j.arth.2020.02.012