文献速递关节外科

外侧单髁膝关节置换术短期至中期生存率及患者与假体特征影响:荷兰关节登记数据分析

A Comprehensive Evaluation of Lateral Unicompartmental Knee Arthroplasty Short to Mid-Term Survivorship, and the Effect of Patient and Implant Characteristics: An Analysis of Data From the Dutch Arthroplasty Register.
PubMed 文献 · J Arthroplasty · 2020-02-18

基于荷兰关节登记2007-2017年数据,比较外侧单髁膝关节置换术(UKA,n=537)与内侧UKA(n=19,295)的生存率。外侧UKA5年翻修率为12.9%,内侧为9.3%,多变量回归显示外侧UKA翻修风险无显著增加(HR 0.87,95%CI 0.66-1.15)。外侧UKA使用活动平台设计与翻修率增加相关,翻修原因和类型因侧别和平台设计而异。

要点

  • 外侧UKA5年翻修率12.9%,内侧9.3%,多变量调整后外侧翻修风险无显著增加。
  • 外侧UKA使用活动平台设计与翻修率增加相关。
  • 骨关节炎进展是两侧翻修的主要原因,内侧UKA还伴有胫骨组件松动。

核心结论

  • 外侧与内侧UKA的生存率相似,但外侧UKA使用活动平台设计时翻修风险显著增加。
  • 失败模式和翻修类型取决于侧别和平台设计。

研究设计与样本

  • 回顾性队列研究,数据来自荷兰关节登记,纳入2007-2017年外侧UKA 537例和内侧UKA 19,295例。
  • 以任何原因翻修为主要终点进行生存分析,并对患者和假体特征进行调整。

主要发现

  • 外侧UKA5年翻修率为12.9%,内侧UKA为9.3%。
  • 多变量回归分析显示外侧UKA翻修风险无显著增加(HR 0.87,95%CI 0.66-1.15)。
  • 分层分析显示患者特征对翻修的影响在外侧和内侧UKA之间相当。
  • 外侧UKA使用活动平台设计与翻修率增加相关。
  • 骨关节炎进展是两侧翻修的主要原因,内侧UKA还伴有胫骨组件松动。

临床怎么用

  • 外侧UKA可考虑作为内侧UKA的替代选择,但应避免使用活动平台设计以降低翻修风险。
  • 临床需关注外侧和内侧间室解剖与运动学差异带来的手术挑战。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The rarity of lateral unicompartmental knee arthroplasty (UKA) results in a lack of large cohort studies and understanding. The aim of this study is to comprehensively evaluate survivorship of lateral UKA with registry data and compare this to medial UKA. METHODS: Lateral (n = 537) and medial UKAs (n = 19,295) in 2007-2017 were selected from the Dutch Arthroplasty Register. Survival analyses were performed with revision for any reason as primary endpoint. Adjustments were made for patient and implant characteristics. Stratified analyses according to patient and implant characteristics were performed. Reasons and type of revision were grouped according to laterality and bearing design. RESULTS: The 5-year revision rate was 12.9% for lateral UKA and 9.3% for medial UKA. Multivariable regression analyses showed no significant increased risk for revision for lateral UKA (hazard ratio 0.87, 95% confidence interval 0.66-1.15). Stratified analyses showed that the effect of patient characteristics on revision was comparable between lateral and medial UKA; however, the use of mobile-bearing design for lateral UKA was associated with increased revision rate. Progression of osteoarthritis was the main reason for revision on both sides accompanied by tibia component loosening for medial UKA. Reasons and type of revision varied depending on bearing design. CONCLUSION: Similar survivorship of lateral and medial UKA was reported. Specifically, there is a notable risk for revision when using mobile-bearing designs for lateral UKA. Failure modes and type of revision depends on laterality and bearing design. These findings emphasize that surgical challenges related to anatomy and kinematics of the lateral and medial knee compartment need to be considered.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Burger JA, Kleeblad LJ, Sierevelt IN, et al. A Comprehensive Evaluation of Lateral Unicompartmental Knee Arthroplasty Short to Mid-Term Survivorship, and the Effect of Patient and Implant Characteristics: An Analysis of Data From the Dutch Arthroplasty Register. J Arthroplasty. 2020. PMID: 32192831. doi:10.1016/j.arth.2020.02.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。