文献速递关节外科

现代锥形楔形股骨柄干骺端填充不足增加下沉与无菌性松动风险:技术与远端髓腔填充至关重要

Inadequate Metadiaphyseal Fill of a Modern Taper-Wedge Stem Increases Subsidence and Risk of Aseptic Loosening: Technique and Distal Canal Fill Matter!
PubMed 文献 · J Arthroplasty · 2020-02-17

该回顾性研究比较两位术者使用相同现代锥形楔形非骨水泥股骨柄的250例初次全髋关节置换,发现积极扩髓并确认扭矩稳定性的术者术后1月下沉显著更少(0.3 vs 1.3 mm),1年额外下沉仅0.8% vs 51.6%,且仅术者技术与小转子下60 mm处髓腔填充率预测下沉,填充不足者出现2例无菌性松动。

要点

  • 积极扩髓最大化内外侧填充并扭矩测试可显著减少早期下沉。
  • 小转子下60 mm处髓腔填充率是下沉的独立预测因素。
  • 填充不足(平均86%)与填充充分(平均95%)相比,1年额外下沉风险大幅增加。

核心结论

  • 最大化内外侧髓腔填充并避免股骨假体尺寸过小可最小化现代锥形楔形非骨水泥柄的下沉并优化稳定性。
  • 未能通过适当扩髓和技术优化髓腔填充可能使股骨组件因无菌性松动而失败。

研究设计与样本

  • 回顾性综述250例连续非骨水泥初次全髋关节置换术,由2位术者完成,所有患者接受相同锥形楔形股骨柄。
  • 术者A积极扩髓,最大化内外侧柄尺寸,并通过扭转测试确认最终扩髓稳定性;术者B未采用此技术。
  • 影像学评估术前骨形态(髓腔喇叭指数)、术后下沉和髓腔填充。

主要发现

  • 两组髓腔喇叭指数无差异(P = .747)。
  • 术者A术后1月下沉显著更少(0.3 vs 1.3 mm,P < .001)。
  • 1年额外下沉仅见于术者A的0.8%(1/119),而术者B为51.6%(33/64,P < .001)。
  • 术者技术和小转子下60 mm处髓腔填充是下沉的唯一预测变量,术者A和B平均填充率分别为95%和86%。
  • 术者B术后2年和3年各出现1例无菌性松动(2%)。

关键数值与推荐

  • 术者A术后1月下沉0.3 mm,术者B为1.3 mm(P < .001)。
  • 1年额外下沉率:术者A 0.8%(1/119),术者B 51.6%(33/64,P < .001)。
  • 小转子下60 mm处平均髓腔填充率:术者A 95%,术者B 86%。
  • 术者B无菌性松动发生率2%(2例),分别发生于术后2年和3年。

临床怎么用

  • 采用积极扩髓技术最大化内外侧髓腔填充,避免股骨假体尺寸过小。
  • 术中通过扭转测试确认最终扩髓的稳定性。
  • 关注小转子下60 mm处的髓腔填充率,作为下沉风险的预测指标。

局限性

  • 回顾性研究设计,证据等级有限。
  • 仅涉及两位术者,技术差异可能受个体因素混杂。
  • 样本量有限(250例),且未报告长期随访结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Adequate interference fit and mechanical stability through optimal surgical technique are essential to prevent subsidence and loosening in cementless total hip arthroplasty. The purpose of this study is to determine the effect of surgical technique on radiographic subsidence and subsequent stability of a modern taper-wedge cementless stem. METHODS: A retrospective review of 250 consecutive cementless primary total hip arthroplasties performed by 2 surgeons was completed. Surgeon A vigorously broached, maximizing the mediolateral stem dimension and confirmed final broach stability with a torsional test, whereas Surgeon B did not. All patients received identical taper-wedge stems. Preoperative bone morphology (canal flare index), postoperative subsidence, and canal fill were radiographically assessed. RESULTS: Canal flare index was not different between groups (P = .747). There was significantly less subsidence at 1 month for Surgeon A (0.3 vs 1.3 mm, P < .001). Additional subsidence at 1 year occurred in only 0.8% of Surgeon A (1/119) compared to 51.6% of Surgeon B stems (33/64, P < .001). Surgeon technique and canal fill measured at 60 mm below the lesser trochanter were the only variables predictive for subsidence, where Surgeon A and B had a mean canal fill of 95% and 86%, respectively. Surgeon B had 2 cases of aseptic loosening (2%) at 2 and 3 years postoperatively. CONCLUSION: These observations support that maximizing mediolateral canal fill and avoiding under-sizing the femoral implant with meticulous broaching technique minimizes subsidence and optimizes stability of modern cementless taper-wedge stems. Failure to optimize canal fill with appropriate broaching and surgical technique may predispose femoral components to failure from aseptic loosening.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Warth LC, Grant TW, Naveen NB, et al. Inadequate Metadiaphyseal Fill of a Modern Taper-Wedge Stem Increases Subsidence and Risk of Aseptic Loosening: Technique and Distal Canal Fill Matter! J Arthroplasty. 2020. PMID: 32147340. doi:10.1016/j.arth.2020.02.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。