文献速递关节外科

对称股骨与胫骨组件的后交叉韧带牺牲型全膝关节置换术在体运动学

In Vivo Knee Kinematics for a Cruciate Sacrificing Total Knee Arthroplasty Having Both a Symmetrical Femoral and Tibial Component.
PubMed 文献 · J Arthroplasty · 2020-02-08

结果显示平均最大负重屈膝111.7°±13.3°,外侧股骨髁后滚-2.5±2.0 mm,内侧髁前移2.5±2.2 mm,轴向旋转6.6°±3.3°,大部分发生在屈膝早期(平均4.9°)。结论认为尽管采用对称设计,仍出现外侧髁后滚和类正常轴向旋转模式,幅度与既往非对称设计报道相似。

要点

  • 对称PCS TKA在负重深屈膝中平均最大屈膝111.7°±13.3°。
  • 外侧股骨髁后滚-2.5±2.0 mm,内侧髁前移2.5±2.2 mm。
  • 轴向旋转平均6.6°±3.3°,早期屈膝占4.9°。

核心结论

  • 对称PCS TKA受试者出现外侧髁后滚和类正常轴向旋转模式,但旋转幅度小于正常膝关节。
  • 后滚和轴向旋转幅度与既往非对称TKA设计报道相似。

研究设计与样本

  • 采用三维到二维配准技术测定股骨髁前后平移、胫股轴向旋转和负重屈膝角度。

主要发现

  • 平均主动最大负重屈膝为111.7°±13.3°。
  • 从完全伸直至最大屈膝,外侧股骨髁平均后滚-2.5±2.0 mm,内侧髁平均前移2.5±2.2 mm。
  • 外侧髁在0°至60°屈膝期间后滚,60°至90°期间平均前移0.3 mm。
  • 平均轴向旋转6.6°±3.3°,大部分发生在屈膝早期,平均4.9°。

临床怎么用

  • 对称PCS TKA在体运动学可表现为外侧髁后滚和类正常轴向旋转,幅度与部分非对称设计相似。
  • 需更多由其他术者植入的病例分析以验证该TKA的运动学表现。

局限性

  • 作者建议需更多由其他外科医生植入该TKA的患者进行分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Early total knee arthroplasty (TKA) designs were symmetrical, but lead to complications due to over-constraint leading to loosening and poor flexion. Next-generation TKAs have been designed to include asymmetry, pertaining to the trochlear groove, femoral condylar shapes, and/or the tibial component. More recently, an advanced posterior cruciate sacrificing (PCS) TKA was designed to include both a symmetrical femoral component with a patented V-shaped trochlear groove and a symmetrical tibial component with an ultracongruent insert, in an attempt to reduce inventory costs. Because previous PCS TKA designs produced variable results, the objective of this study is to determine and evaluate the in vivo kinematics for subjects implanted with this symmetrical TKA. METHODS: Twenty-one subjects, implanted with symmetrical PCS fixed-bearing TKA, were asked to perform a weight-bearing deep knee bend (DKB) while under fluoroscopic surveillance. A 3-dimensional to 2-dimensional registration technique was used to determine each subject's anteroposterior translation of lateral and medial femoral condyles as well as tibiofemoral axial rotation and their weight-bearing knee flexion. RESULTS: During the DKB, the average active maximum weight-bearing flexion was 111.7° ± 13.3°. On average, from full extension to maximum knee flexion, subjects experienced -2.5 ± 2.0 mm of posterior femoral rollback of the lateral condyle and 2.5 ± 2.2 mm of medial condyle motion in the anterior direction. This medial condyle motion was consistent for the majority of the subjects, with the lateral condyle exhibiting rollback from 0° to 60° of flexion and then experienced an average anterior motion of 0.3 mm from 60° to 90° of knee flexion. On average, the subjects in this study experienced 6.6°± 3.3° of axial rotation, with most of the rotation occurring in early flexion, averaging 4.9°. CONCLUSION: Although subjects in this study were implanted with a symmetrical PCS TKA, they did experience femoral rollback of the lateral condyle and a normal-like pattern of axial rotation, although less in magnitude than the normal knee. The normal axial rotation pattern occurred because the lateral condyle rolled in the posterior direction, while the medial condyle moved in the anterior direction. Interestingly, the magnitude of posterior femoral rollback and axial rotation for subjects in this study was similar in magnitude reported in previous studies pertaining to asymmetrical TKA designs. It is proposed that more patients be analyzed having this TKA implanted by other surgeons.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Khasian M, LaCour MT, Coomer SC, et al. In Vivo Knee Kinematics for a Cruciate Sacrificing Total Knee Arthroplasty Having Both a Symmetrical Femoral and Tibial Component. J Arthroplasty. 2020. PMID: 32111514. doi:10.1016/j.arth.2020.02.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。