文献速递关节外科

模块颈股骨柄颈锥腐蚀致ALTR翻修全髋的临床结果

Clinical Results of Revision Hip Arthroplasty for Neck-Taper Corrosion and Adverse Local Tissue Reactions Around a Modular Neck Stem.
PubMed 文献 · J Arthroplasty · 2020-02-28

作者建议选用翻修型股骨柄及大直径股骨头或双动界面。

要点

  • 翻修术后假体相关并发症10%,其中6髋再翻修,主要为脱位、股骨组件无菌性松动和假体周围骨折。
  • 随访期内无ALTR复发或腹股沟痛复发,除2例外离子水平在翻修术后1年内恢复正常。
  • 以再翻修为终点,翻修全髋生存率32个月94%(95%CI 84-98),63个月82%(95%CI 56-93)。

核心结论

  • 模块颈股骨柄颈锥腐蚀行翻修全髋的术中并发症、术后并发症及再翻修率与其他原因(感染、骨折、松动)股骨翻修术相当。
  • 建议选择翻修型股骨柄以降低股骨松动或假体周围骨折风险,并选用大直径股骨头或双动界面以降低脱位风险。

研究设计与样本

  • 回顾性病例系列,纳入80髋(77例)因颈-柄腐蚀行翻修全髋关节置换术的患者。
  • 记录术中及术后并发症、临床结果、再翻修率及术后离子水平,平均随访45.3±16.3个月(范围24-81个月)。

主要发现

  • 翻修术中无机械性并发症。
  • 8髋(10%)发生翻修假体相关术后并发症,其中6髋再翻修:术后假体脱位4髋(2髋非手术治疗)、股骨组件无菌性松动2髋、假体周围股骨骨折2髋。
  • 随访期内无ALTR复发,也无腹股沟痛复发。
  • 除2例外,离子水平在翻修术后1年内恢复正常。
  • 以任何原因再翻修全髋为终点,生存率32个月为94%(95%CI 84-98),63个月为82%(95%CI 56-93)。

关键数值与推荐

  • 本机构模块颈股骨柄周围ALTR导致13.5%的翻修率。
  • 翻修术后假体相关并发症率为10%(8/80髋),其中再翻修率为6/8。
  • 翻修全髋生存率:32个月94%(95%CI 84-98),63个月82%(95%CI 56-93)。

临床怎么用

  • 对模块颈股骨柄颈锥腐蚀所致ALTR行翻修全髋时,可选择翻修型股骨柄以降低股骨松动或假体周围骨折风险。
  • 选用大直径股骨头或双动界面以降低术后脱位风险。
  • 术后应监测离子水平,多数在1年内恢复正常,但需注意个别未恢复正常的情况。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Adverse local tissue reactions (ALTRs) around a modular neck stem at our institution lead to a 13.5% rate of revision. The purpose of this study was to report the clinical results of revision total hip arthroplasty (THA) in this patient population. METHODS: We identified 80 hips in 77 patients who underwent revision THA due to neck-stem corrosion. Intraoperative and postoperative complications, clinical outcomes, re-revision rates, and the postoperative ion levels were recorded. RESULTS: The mean follow-up period after revision was 45.3 ± 16.3 months (range 24-81 months). There were no intraoperative mechanical complications during the revision surgery. Eight hips (10%) had postoperative complications related to the revision implant, of which 6/8 came to re-revision: postoperative implant dislocation in 4 hips-2 treated nonsurgically, aseptic loosening of femoral component in 2 hips, and periprosthetic femoral fracture in 2 hips. No patients had recurrence of ALTR nor the recurrence of groin pain within the follow-up period. With 2 exceptions, ion levels normalized within one year of the revision surgery. The survival rate was 94% (95% confidence interval 84-98) at 32 months and 82% (95% confidence interval 56-93) at 63 months after revision THA (using re-revision THA due to any reason as the endpoint). CONCLUSION: Intraoperative complication, postoperative complication, and re-revision rates are equivalent to femoral revision surgeries for other causes (infection, fracture, loosening). We recommend selecting revision-type stems to minimize the risk of femoral loosening or periprosthetic fracture, and larger femoral heads or dual mobility bearings to minimize the risk of dislocation.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Inoue D, Restrepo C, Nourie B, et al. Clinical Results of Revision Hip Arthroplasty for Neck-Taper Corrosion and Adverse Local Tissue Reactions Around a Modular Neck Stem. J Arthroplasty. 2020. PMID: 32199761. doi:10.1016/j.arth.2020.02.057

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。