文献速递关节外科

α-防御素诊断准确性取决于所用感染定义

Alpha Defensin: A Diagnostic Accuracy Depending on the Infection Definition Used.
PubMed 文献 · J Arthroplasty · 2019-12-18

多中心队列纳入136例疼痛性关节置换患者,按MSIS、IDSA、EBJIS三种标准分类感染与否,计算α-防御素定性检测(ADLF)的敏感性和特异性。ADLF敏感性随标准不同为55.8%-87.8%,特异性94%-97%;

要点

  • ADLF敏感性因感染定义而异:对比MSIS为87.8%,IDSA为70%,EBJIS为55.8%。
  • ADLF特异性稳定在94%-97%,与滑液培养相关性良好(r=0.73)。

核心结论

  • ADLF敏感性随所用感染定义标准变化较大,但特异性均表现优秀。

研究设计与样本

  • 多中心队列研究,纳入136例疼痛性关节置换患者,按MSIS、IDSA、EBJIS三种标准分类感染与否。

主要发现

  • EBJIS评分阳性68例,IDSA阳性50例,MSIS阳性41例,ADLF阳性40例。
  • ADLF敏感性对比MSIS为87.8%,对比IDSA为70%,对比EBJIS为55.8%。
  • ADLF特异性范围为94%-97%。
  • 滑液培养与ADLF相关性良好(r=0.73);ADLF与EBJIS(r=0.58)、IDSA(r=0.68)、MSIS(r=0.84)呈低至优秀的相关性。

临床怎么用

  • 解读ADLF结果时需考虑所用感染定义标准,其敏感性在EBJIS标准下较低。

局限性

  • EBJIS评分结果与培养结果显著不同,可能解释ADLF对比EBJIS的低敏感性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of this study was to evaluate the alpha defensin qualitative detection (ADLF) sensitivity and specificity as compared with 3 standard classifications in the diagnostic management of chronic prosthetic joint infections. MATERIALS AND METHODS: A multicenter cohort of 136 patients with a painful arthroplasty was classified into either infected or noninfected according to the Musculoskeletal Infection Society (MSIS) score, Infectious Diseases Society of America (IDSA) score, European Bone and Joint Infection Society (EBJIS) score. The sensitivity and specificity of the ADLF test were calculated for each score. Spearman's correlations between all scores were then analyzed, and multiple logistic regression was applied to identify independent variables strongly connected to the prosthetic joint infection probability. RESULTS: The EBJIS score was positive in 68 patients, IDSA score in 50 patients, MSIS score in 41 patients, and ADLF in 40 patients. The ADLF sensitivity was 87.8% compared with MSIS, 70% compared with IDSA, and 55.8% compared with EBJIS. The ADLF specificity was in the range of 94%-97%. A good correlation was observed between synovial fluid cultures and ADLF (r = 0.73). Low to excellent correlations were recorded between ADLF and the EBJIS (r = 0.58), IDSA (r = 0.68), and MSIS (r = 0.84) scores. The synovial fluid's white blood cell count was proven to be the biological test that most influenced the probability of a positive culture (P value: .005). DISCUSSION: The ADLF sensitivity was variable, whereas its specificity was excellent. The EBJIS score results significantly differed from those obtained via cultures, which possibly explains the ADLF low sensitivity compared with that of the EBJIS score.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Huard M, Detrembleur C, Poilvache H, et al. Alpha Defensin: A Diagnostic Accuracy Depending on the Infection Definition Used. J Arthroplasty. 2019. PMID: 32139189. doi:10.1016/j.arth.2019.12.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。