文献速递关节外科

机器人辅助与不辅助单髁膝关节置换术的三年生存率比较

The three-year survivorship of robotically assisted versus non-robotically assisted unicompartmental knee arthroplasty.
PubMed 文献 · Bone Joint J · 2020-01-01

基于澳大利亚国家关节置换登记系统2015至2018年骨关节炎单髁膝关节置换术数据,比较Mako机器人辅助Restoris MCK假体与非机器人辅助ZUK假体及其他非机器人辅助单髁膝关节置换术的累积翻修率。结果显示机器人辅助组与ZUK组翻修率无差异,但显著低于其他非机器人辅助术式;然而机器人辅助组感染翻修率显著更高。

要点

  • 机器人辅助Restoris UKA与ZUK UKA的三年翻修率无显著差异。
  • 机器人辅助Restoris UKA总体翻修率显著低于其他非机器人辅助UKA(HR 0.58)。
  • 机器人辅助UKA的感染相关翻修率显著高于两个对照组,需进一步研究。

核心结论

  • Mako机器人辅助UKA与ZUK UKA相比具有相当的短期生存率,且优于所有其他非机器人辅助UKA,但早期感染翻修率较高需进一步调查。

研究设计与样本

  • 回顾性队列研究,分析澳大利亚骨科协会国家关节置换登记系统(AOANJRR)2015至2018年因骨关节炎行UKA的数据。
  • 使用Cox比例风险比和Kaplan-Meier生存估计比较Mako辅助Restoris MCK UKA、非机器人辅助ZUK UKA及其他非机器人辅助UKA的翻修率。

主要发现

  • Mako辅助Restoris UKA与ZUK UKA相比,0至9个月翻修HR 1.14(95% CI 0.71至1.83;p=0.596),9个月以上HR 0.66(95% CI 0.42至1.02;p=0.058)。
  • Mako辅助Restoris UKA三年总体翻修率显著低于其他非机器人辅助UKA(HR 0.58,95% CI 0.42至0.79;p<0.001)。
  • 无菌性松动翻修:Mako辅助Restoris UKA低于所有其他非机器人辅助UKA(全期HR 0.34,95% CI 0.17至0.65;p=0.001),但与ZUK假体无差异。
  • 感染翻修:Mako辅助Restoris UKA显著高于ZUK(全期HR 2.91,95% CI 1.22至6.98;p=0.016),也显著高于其他非机器人辅助UKA(0至3个月HR 5.57,95% CI 2.17至14.31;p<0.001)。

关键数值与推荐

  • 机器人辅助UKA与ZUK UKA翻修率无显著差异(0-9个月p=0.596;9个月以上p=0.058)。
  • 机器人辅助UKA总体翻修率显著低于其他非机器人辅助UKA(HR 0.58;p<0.001)。
  • 机器人辅助UKA无菌性松动翻修率显著低于其他非机器人辅助UKA(HR 0.34;p=0.001)。
  • 机器人辅助UKA感染翻修率显著高于ZUK(HR 2.91;p=0.016)和其他非机器人辅助UKA(0-3个月HR 5.57;p<0.001)。

临床怎么用

  • 机器人辅助UKA可考虑用于骨关节炎单髁置换,其短期生存率与高性能非机器人假体相当且优于多数非机器人UKA。
  • 术后需警惕早期感染风险,加强感染预防和监测。

局限性

  • 原文未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: There has been a significant reduction in unicompartmental knee arthroplasty (UKA) procedures recorded in Australia. This follows several national joint registry studies documenting high UKA revision rates when compared to total knee arthroplasty (TKA). With the recent introduction of robotically assisted UKA procedures, it is hoped that outcomes improve. This study examines the cumulative revision rate of UKA procedures implanted with a newly introduced robotic system and compares the results to one of the best performing non-robotically assisted UKA prostheses, as well as all other non-robotically assisted UKA procedures. METHODS: Data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) for all UKA procedures performed for osteoarthritis (OA) between 2015 and 2018 were analyzed. Procedures using the Restoris MCK UKA prosthesis implanted using the Mako Robotic-Arm Assisted System were compared to non-robotically assisted Zimmer Unicompartmental High Flex Knee System (ZUK) UKA, a commonly used UKA with previously reported good outcomes and to all other non-robotically assisted UKA procedures using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship. RESULTS: There was no difference in the rate of revision when the Mako-assisted Restoris UKA was compared to the ZUK UKA (zero to nine months: HR 1.14 (95% CI 0.71 to 1.83; p = 0.596) vs nine months and over: HR 0.66 (95% CI 0.42 to 1.02; p = 0.058)). The Mako-assisted Restoris had a significantly lower overall revision rate compared to the other types of non-robotically assisted procedures (HR 0.58 (95% confidence interval (CI) 0.42 to 0.79); p < 0.001) at three years. Revision for aseptic loosening was lower for the Mako-assisted Restoris compared to all other non-robotically assisted UKA (entire period: HR 0.34 (95% CI 0.17 to 0.65); p = 0.001), but not the ZUK prosthesis. However, revision for infection was significantly higher for the Mako-assisted Restoris compared to the two comparator groups (ZUK: entire period: HR 2.91 (95% CI 1.22 to 6.98; p = 0.016); other non-robotically assisted UKA: zero to three months: HR 5.57 (95% CI 2.17 to 14.31; p < 0.001)). CONCLUSION: This study reports comparable short-term survivorship for the Mako robotically assisted UKA compared to the ZUK UKA and improved survivorship compared to all other non-robotic UKA. These results justify the continued use and investigation of this procedure. However, the higher rate of early revision for infection for robotically assisted UKA requires further investigation. Cite this article: Bone Joint J 2020;102-B(3):319-328.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. St Mart JP, de Steiger RN, Cuthbert A, et al. The three-year survivorship of robotically assisted versus non-robotically assisted unicompartmental knee arthroplasty. Bone Joint J. 2020. PMID: 32114810. doi:10.1302/0301-620X.102B3.BJJ-2019-0713.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。