文献速递创伤骨科关节外科

Thompson半髋置换治疗股骨颈骨折与脱位风险增加相关

Thompson Hemiarthroplasty for Femoral Neck Fracture Is Associated With Increased Risk of Dislocation.
PubMed 文献 · J Arthroplasty · 2020-01-30

这项多中心回顾性研究纳入2009至2017年间4116例因股骨颈骨折行髋半髋置换的患者,评估患者因素、假体选择及植入物特征对脱位风险的影响。结果显示总体脱位率为1.5%(63/4116),Thompson假体脱位率显著更高(24/273,3.7%,P<.05),而骨水泥与非骨水泥、可变与固定偏距、单块与模块化设计及术者资历均非显著危险因素。

要点

  • Thompson假体半髋置换脱位率3.7%,显著高于同期其他假体选择。
  • 患者年龄、性别、术前术后AMTS及ASA分级均非脱位显著预测因素。
  • 骨水泥固定、偏距设计、假体模块化及术者资历与脱位风险无显著相关。

核心结论

  • Thompson髋半髋置换相比同期其他假体选择与更高的脱位率相关,使用时应结合这一需再次手术的主要风险因素加以考虑。

研究设计与样本

  • contemporaneous large multicenter retrospective study,reviewed radiographic records of 4116 consecutive patients who underwent hip hemiarthroplasty for femoral neck fracture between January 1, 2009 and September 30, 2017 at 3 acute hospitals, in conjunction with United Kingdom National Hip Fracture Database records.

主要发现

  • 63 of 4116 (1.5%) dislocations were identified.
  • Patient age, gender, preoperative abbreviated mental test score, postoperative abbreviated mental test score, and American Society of Anaesthesiologists grade were not found to be significant predictors of dislocation rates (P < .05).
  • The Furlong prosthesis was the most commonly used implant (2280/4116, 55.4%) followed by the Exeter V40 + Unitrax head (1179/4116, 28.6%), other implants used during the study period were the monoblock Austin-Moore and Thompson implants.
  • Hemiarthroplasty operations undertaken with the Thompson (24/273, 3.7%) were found to have significantly higher dislocation rates (P < .05).
  • Cemented vs uncemented, variable vs fixed offset, and monoblock vs modular implant designs did not contribute to higher dislocation rates (P < .05).

关键数值与推荐

  • Thompson假体半髋置换脱位率为24/273(3.7%),显著高于同期其他假体(P < .05)。
  • Furlong假体使用率最高(2280/4116,55.4%),其次为Exeter V40 + Unitrax头(1179/4116,28.6%)。
  • 总体脱位率为63/4116(1.5%)。

临床怎么用

  • 在选择半髋置换假体时,应考虑到Thompson假体与更高的脱位风险相关,尤其对于需再次手术风险较高的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This contemporaneous large multicenter retrospective study reflective of current practice, assesses the impact of patient factors, prosthesis selection, and implant features on the risk of dislocation after hip hemiarthroplasty for femoral neck fracture. METHODS: Radiographic records for 4116 consecutive patients who underwent a hip hemiarthroplasty between January 1, 2009 and September 30, 2017 at 3 acute hospitals (including a regional major trauma center) for a neck of femur fracture were reviewed in conjunction with United Kingdom National Hip Fracture Database records. RESULTS: In total, 4116 patients were eligible for inclusion in the study; 63 of 4116 (1.5%) dislocations were identified. Patient age, gender, preoperative abbreviated mental test score, postoperative abbreviated mental test score, and American Society of Anaesthesiologists grade were not found to be significant predictors of dislocation rates (P < .05). The Furlong prosthesis was the most commonly used implant (2280/4116, 55.4%) followed by the Exeter V40 + Unitrax head (1179/4116, 28.6%), other implants used during the study period were the monoblock Austin-Moore and Thompson implants. Hemiarthroplasty operations undertaken with the Thompson (24/273, 3.7%) were found to have significantly higher dislocation rates (P < .05). Cemented vs uncemented, variable vs fixed offset, and monoblock vs modular implant designs did not contribute to higher dislocation rates (P < .05). Surgeon seniority was also not a significant risk factor for subsequent dislocation (P < .05). CONCLUSIONS: Thompson hip hemiarthroplasties are associated with higher dislocation rates when compared to a contemporaneous cohort of implant choices and considerations for their use should be made in conjunction with this major risk factor for the need for subsequent operations.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Chan GK, Aladwan R, Hook SE, et al. Thompson Hemiarthroplasty for Femoral Neck Fracture Is Associated With Increased Risk of Dislocation. J Arthroplasty. 2020. PMID: 32127222. doi:10.1016/j.arth.2020.01.061

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。